IEC 61223-3-5:2019
Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance and constancy tests - Imaging performance of computed tomography X-ray equipment
Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance and constancy tests - Imaging performance of computed tomography X-ray equipment
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 126
- Дата публикации:
- 16 сентября 2019 г.
- Издание:
- IEC IS 61223 edition 2 version 1
- ICS:
- 11.040.50
IEC 61223-3-5:2019 applies to CT SCANNERS that conform to IEC 60601-2-44:2009, IEC 60601-2-44:2009/AMD1:2012 and IEC 60601-2-44:2009/AMD1:2012AMD2:2016. IEC 60601-2-44 and this document • defines the essential parameters which describe the performance of CT SCANNERS with regard to image quality, RADIATION OUTPUT and PATIENT positioning; the list of parameters to be tested can be found in section 4.3, • defines the methods of testing the essential parameters, and • evaluates compliance with the tolerances of the parameters SPECIFIED by the ACCOMPANYING DOCUMENTS. The methods defined in IEC 60601-2-44 and this document rely on non-invasive measurements, using appropriate test equipment, performed during or after installation. Signed statements covering steps in the installation procedure can be used as part of the ACCEPTANCE TEST report. This document applies to ACCEPTANCE TESTS and CONSTANCY TESTS on a CT SCANNER. The aim of the ACCEPTANCE TESTS is to verify compliance of the installation or MAJOR SERVICE ACTION with specifications affecting the image quality, RADIATION OUTPUT and PATIENT positioning. The CONSTANCY TESTS are performed to ensure that the functional performance of EQUIPMENT meets ESTABLISHED CRITERIA and to enable the early recognition of changes in the properties of components of the EQUIPMENT, and to verify compliance with specifications affecting the image quality, RADIATION OUTPUT and PATIENT positioning. This document also contains requirements associated with ACCEPTANCE and CONSTANCY TESTING for the ACCOMPANYING DOCUMENTS of the CT SCANNER. This document does not apply to • aspects of mechanical and electrical safety, and • aspects of mechanical, electrical and software performance, unless they are essential for performing the ACCEPTANCE TESTS and CONSTANCY TESTS, and are directly affecting image quality, RADIATION OUTPUT and PATIENT positioning. IEC 61223-3-5:2019 cancels and replaces the first edition published in 2004, and the second edition of IEC 61223-2-6 published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical change with respect to the previous edition and to IEC 61223-2-6: 1) modification of the RADIATION protection and control; 2) modification of the acceptance testing; 3) introduction of constancy testing. The contents of the corrigendum of June 2022 have been included in this copy.
Abstract
Overview
IEC 61223-3-5:2019 is an International Electrotechnical Commission (IEC) standard that addresses the evaluation and routine testing of computed tomography (CT) X-ray equipment in medical imaging departments. This document specifically focuses on acceptance testing and constancy testing to ensure the imaging performance, radiation output, and patient positioning of CT scanners. It applies to CT scanners that conform to IEC 60601-2-44:2009 and its amendments, providing standardized methods for verifying that equipment meets critical specifications.
By defining performance criteria and non-invasive testing methods, IEC 61223-3-5:2019 helps medical organizations, service engineers, and quality assurance professionals maintain high standards of safety and image quality in radiological diagnostics.
Key Topics
- Acceptance Tests: Establishes processes for verifying new CT scanner installations or significant servicing actions, ensuring compliance with specifications relating to image quality, radiation output, and patient positioning.
- Constancy Tests: Involves periodic testing to confirm that essential CT scanner parameters remain within acceptable tolerance levels over time, enabling early detection of component degradation or changes in performance.
- Performance Parameters: Defines key parameters (e.g., spatial resolution, mean CT number, noise, uniformity, dose indices, patient positioning accuracy) that characterize imaging performance.
- Non-invasive Methods: Specifies that all testing procedures employ non-invasive measurements with appropriate test equipment.
- Documentation: Mandates reporting and documentation as part of the acceptance and constancy test procedures, ensuring traceability and compliance verification.
- Radiation Control: Includes updated requirements for radiation protection and control, reflecting recent advances and regulatory expectations.
- Alignment with Other Standards: Designed to harmonize with IEC 60601-2-44, utilizing shared methods and terminology.
Applications
IEC 61223-3-5:2019 is essential for a variety of stakeholders in the medical imaging field:
- Medical Imaging Departments: Facilitates the commissioning and ongoing performance monitoring of CT equipment, supporting safe and accurate clinical diagnostics.
- Quality Assurance Teams: Provides a framework for developing routine quality assurance (QA) protocols and compliance checks, which are critical for patient safety, clinical accuracy, and regulatory inspections.
- Service Engineers & Maintenance Providers: Assists in post-installation testing and the evaluation of major service interventions, ensuring that system performance meets manufacturer and contractual requirements.
- Regulatory Compliance: Supports adherence to international best practices and national regulations by defining standardized test methods and criteria for CT imaging equipment performance.
- Equipment Manufacturers: Guides the development of accompanying documentation and ensures that supplied CT systems can demonstrate compliance with recognized international standards.
These applications help healthcare providers mitigate risk, uphold diagnostic consistency, and optimize patient care.
Related Standards
IEC 61223-3-5:2019 is closely linked with several other standards in medical imaging and equipment safety, including:
- IEC 60601-2-44: Essential safety and performance requirements for CT X-ray equipment.
- IEC 60601-1: General requirements for basic safety and essential performance of medical electrical equipment.
- IEC TR 60788: Glossary of defined terms applicable to medical electrical equipment.
- Other parts of IEC 61223 series: Covering broader evaluation and testing aspects for different imaging modalities.
Adherence to IEC 61223-3-5:2019 aligns CT imaging practices with globally recognized benchmarks for quality, accuracy, and safety in healthcare environments.
Keywords: IEC 61223-3-5:2019, acceptance testing, constancy testing, CT scanner, computed tomography, medical imaging departments, image quality, radiation output, patient positioning, routine testing, IEC standards, quality assurance, CT equipment compliance.
Технические детали
- Технический комитет
- SC 62B - Medical imaging equipment, software, and systems
- SKU
- IEC 61223-3-5:2019
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC TR 62348:2012
ДействующийAssessment of the impact of the most significant changes in Amendment 1 to IEC 60601-1:2005 and mapping of th…
Overview IEC TR 62348:2012 is a Technical Report from the International Electrotechnical Commission that helps users transition from IEC 60601-1:2005 (Edition 3) to the amended edition (Amendment 1:2…
IEC 61223-3-5:2004
ДействующийEvaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performa…
Overview IEC 61223-3-5:2004 is an international standard established by the International Electrotechnical Commission (IEC) that defines acceptance testing procedures for computed tomography (CT) X-r…
IEC 62590-2-2:2026
ДействующийRailway applications - Electronic power converters for fixed installations - Part 2-2: DC Traction applicatio…
Overview IEC 62590-2-2:2026 is an international standard developed by the International Electrotechnical Commission (IEC) focusing on railway applications, specifically the electronic power converter…
IEC 61753-042-02:2026
ДействующийFibre optic interconnecting devices and passive components - Performance standard - Part 042-02: Plug-pigtail…
Overview IEC 61753-042-02:2026 establishes the minimum performance, test, and measurement requirements for plug-pigtail and plug-receptacle style OTDR (Optical Time-Domain Reflectometer) reflecting d…
IEC 61837-2:2018
ДействующийSurface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal le…
Overview IEC 61837-2:2018 - Surface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal lead connections - Part 2: Ceramic enclosures (Edition 3.0, 2018…
IEC 61851-23-1:2026
ДействующийElectric vehicle conductive charging system - Part 23-1: DC electric vehicle supply equipment - Automated con…
Overview IEC 61851-23-1:2026 is an international standard published by the International Electrotechnical Commission (IEC) that specifies requirements for DC electric vehicle supply equipment (EVSE)…
IEC 63506:2026
ДействующийCalibration of the prompt fission neutron logging tools
Overview IEC 63506:2026 - Calibration of the Prompt Fission Neutron Logging Tools is the international standard that specifies the calibration methods for prompt fission neutron (PFN) logging tools,…
IEC 63589-1:2026
ДействующийLinear accelerator - Electron linear accelerator for radiation processing - Part 1: General requirements and…
Overview IEC 63589-1:2026 specifies the general requirements and test methods for electron linear accelerator devices used in radiation processing. Developed by the International Electrotechnical Com…