IEC 61300-3-39:2011
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-39: Examinations and measurements - Physical contact (PC) optical connector reference plug selection for return loss measurements
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-39: Examinations and measurements - Physical contact (PC) optical connector reference plug selection for return loss measurements
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 26
- Дата публикации:
- 22 ноября 2011 г.
- Издание:
- IEC IS 61300 edition 2 version 1
- ICS:
- 33.180.20
IEC 61300-3-39:2011 selects non-angled physical contact (PC) optical connector plugs for use as the reference plug in the return loss RL measurement and to define an acceptance return loss value RLa for use in plug acceptance testing. This procedure is for use to guarantee a certain return loss value RL when two plugs have been successfully tested against the reference connector when randomly mated. This second edition of IEC 61300-3-39 cancels and replaces the first edition published in 1997 and constitutes a technical revision. Changes from the previous edition are structure of the standard, general description and the Annex.
Abstract
Overview
IEC 61300-3-39:2011 is an international standard developed by the International Electrotechnical Commission (IEC) that defines procedures for selecting physical contact (PC) optical connector reference plugs used in return loss (RL) measurements. Specifically, it focuses on non-angled PC optical connector plugs, providing a method to choose reference plugs and establish acceptance return loss values for plug testing. As part of the IEC 61300 series on fibre optic interconnecting devices and passive components, this standard ensures consistent and reliable measurement of return loss, which is critical to evaluating the quality of fibre optic connections.
The 2011 edition supersedes the 1997 version with technical revisions involving the structure, general descriptions, and annex content. Its goal is to guarantee that two randomly mated PC optical plugs meet minimum return loss requirements for optimal performance in fibre optic systems.
Key Topics
-
Reference Plug Selection: Defines a "reference plug" as a member of a group of minimum three plugs that, when mated in all combinations, yield a specified return loss (RL) value. This plug serves as the measurement baseline for return loss testing.
-
Return Loss (RL) Measurement: The standard clarifies how to measure RL at the mating points of PC optical connectors, which is influenced by microscopic surface damage and refractive index variations caused during polishing. These factors create reflections affecting signal integrity.
-
Acceptance Return Loss Value (RLa): To ensure any randomly mated plugs exceed a minimum acceptable RL, the standard establishes an acceptance RL value for plugs tested against the reference plug. This value depends on the reference plug's RL and the minimum RL allowed for random mated pairs.
-
Intrinsic Return Loss (IRL): Introduces IRL as a theoretical parameter representing the return loss of a plug mated to itself. IRL helps derive the RL of connections formed by any two plugs, enabling the selection of suitable reference plugs.
-
Measurement Procedure: Provides step-by-step methods to:
- Select the reference plug from a group
- Measure minimum acceptable RL of plugs under test
- Consider accuracy and instrumentation requirements
-
Mathematical Relationships: The standard includes critical formulas linking RL, RLa, and IRL values that underpin the testing methodology and acceptance criteria.
Applications
IEC 61300-3-39:2011 is essential for manufacturers, testers, and engineers working with fibre optic interconnecting devices and passive components, particularly those involved in quality control and specification compliance of optical connectors. Practical applications include:
-
Quality Assurance in Connector Production: Ensuring plugs meet minimum return loss specifications before shipment or assembly.
-
Connector Performance Verification: Validating that randomly mated PC optical connectors achieve required signal integrity and low reflection losses in field or laboratory conditions.
-
Standardized Testing: Providing a reproducible and internationally recognized procedure for return loss measurements using reference plugs, supporting interoperability between devices from different suppliers.
-
Fibre Optic Network Deployment: Assisting in the assessment of optical connectors to minimize link losses that hurt network performance and reliability.
-
Research and Development: Offering benchmarking measurement techniques for new connector designs and polishing methods.
Related Standards
For comprehensive testing and measurement of fibre optic components, IEC 61300-3-39:2011 should be used alongside the following standards:
-
IEC 61300-3-6: Basic test and measurement procedures - Return loss measurement methods for fibre optic connectors.
-
IEC 61300 Series: Covers a wide range of tests and measurement protocols for fibre optic interconnecting devices and passive components.
-
ISO/IEC Directives, Part 2: Provides the framework for the preparation and drafting of international standards.
Summary
IEC 61300-3-39:2011 sets the internationally accepted method for selecting physical contact (PC) optical connector reference plugs and defining acceptance return loss values for plug testing. By standardizing return loss testing protocols, it improves consistency, ensures quality, and supports reliable performance of fibre optic interconnections worldwide. The standard’s focus on non-angled PC connectors and its precise mathematical approach make it vital for industries and professionals committed to high-performance optical fibre networks. Implementing IEC 61300-3-39 helps guarantee that optical connectors meet stringent return loss criteria, enhancing system efficiency and longevity.
Технические детали
- Технический комитет
- SC 86B - Fibre optic interconnecting devices and passive components
- SKU
- IEC 61300-3-39:2011
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC 61300-2-33:2026
ДействующийFibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-3…
Overview IEC 61300-2-33:2026 is an international standard developed by the International Electrotechnical Commission (IEC). It specifies basic test and measurement procedures for fibre optic intercon…
IEC 61300-3-6:2008
ДействующийFibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6…
Overview IEC 61300-3-6:2008 is an internationally recognized standard published by the International Electrotechnical Commission (IEC) that defines the basic test and measurement procedures for asses…
IEC 62590-2-2:2026
ДействующийRailway applications - Electronic power converters for fixed installations - Part 2-2: DC Traction applicatio…
Overview IEC 62590-2-2:2026 is an international standard developed by the International Electrotechnical Commission (IEC) focusing on railway applications, specifically the electronic power converter…
IEC 61753-042-02:2026
ДействующийFibre optic interconnecting devices and passive components - Performance standard - Part 042-02: Plug-pigtail…
Overview IEC 61753-042-02:2026 establishes the minimum performance, test, and measurement requirements for plug-pigtail and plug-receptacle style OTDR (Optical Time-Domain Reflectometer) reflecting d…
IEC 61837-2:2018
ДействующийSurface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal le…
Overview IEC 61837-2:2018 - Surface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal lead connections - Part 2: Ceramic enclosures (Edition 3.0, 2018…
IEC 61851-23-1:2026
ДействующийElectric vehicle conductive charging system - Part 23-1: DC electric vehicle supply equipment - Automated con…
Overview IEC 61851-23-1:2026 is an international standard published by the International Electrotechnical Commission (IEC) that specifies requirements for DC electric vehicle supply equipment (EVSE)…
IEC 63506:2026
ДействующийCalibration of the prompt fission neutron logging tools
Overview IEC 63506:2026 - Calibration of the Prompt Fission Neutron Logging Tools is the international standard that specifies the calibration methods for prompt fission neutron (PFN) logging tools,…
IEC 63589-1:2026
ДействующийLinear accelerator - Electron linear accelerator for radiation processing - Part 1: General requirements and…
Overview IEC 63589-1:2026 specifies the general requirements and test methods for electron linear accelerator devices used in radiation processing. Developed by the International Electrotechnical Com…