IEC 62127-1:2022
Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields
Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 333
- Дата публикации:
- 25 марта 2022 г.
- Издание:
- IEC IS 62127 edition 2 version 1
- ICS:
- 17.140.50
IEC 62127-1:2022 specifies methods of use of calibrated hydrophones for the measurement in liquids of acoustic fields generated by ultrasonic medical equipment including bandwidth criteria and calibration frequency range requirements in dependence on the spectral content of the fields to be characterized. This document: - defines a group of acoustic parameters that can be measured on a physically sound basis; - defines a second group of parameters that can be derived under certain assumptions from these measurements, and called derived intensity parameters; - defines a measurement procedure that can be used for the determination of acoustic pressure parameters; - defines the conditions under which the measurements of acoustic parameters can be made using calibrated hydrophones; - defines procedures for correcting for limitations caused by the use of hydrophones with finite bandwidth and finite active element size, and for estimating the corresponding uncertainties. IEC 62127-1:2022 cancels and replaces the first edition published in 2007 and Amendment 1:2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. a) The upper frequency limit of 40 MHz has been removed. b) Hydrophone sensitivity definitions have been changed to recognize sensitivities as complex-valued quantities. c) Procedures and requirements for narrow-band approximation and broadband measurements have been modified; details on waveform deconvolution have been added. d) Procedures for spatial averaging correction have been amended. e) Annex D, Annex E and bibliography have been updated to support the changes of the normative parts.
Abstract
Overview
IEC 62127-1:2022 - Ultrasonics: Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields defines standardized methods for using calibrated hydrophones to measure acoustic fields in liquids generated by medical ultrasonic equipment. The standard sets bandwidth and calibration frequency-range requirements based on the spectral content of fields, specifies which acoustic quantities can be measured directly and which are derived, and lays out procedures for correcting hydrophone limitations (finite bandwidth and active element size) and estimating measurement uncertainty.
Key topics and technical requirements
- Hydrophone calibration and sensitivity
- Requirements for using calibrated hydrophones, including recognition of complex-valued sensitivity (phase and magnitude).
- Bandwidth and calibration frequency-range criteria tied to field spectral content.
- Primary and derived acoustic parameters
- Defines a set of primary (measured) acoustic parameters and derived intensity parameters (e.g., pulse-pressure-squared integrals) that may be computed under stated assumptions.
- Beam characterization parameters such as peak-compressional/peak-rarefactional pressures, spatial-peak RMS pressure, and local distortion parameter.
- Measurement procedures and corrections
- Procedures for alignment, positioning, water-bath setup, data acquisition and analysis.
- Waveform deconvolution, modified narrow-band and broadband measurement approaches, and guidance on validation of deconvolution implementations.
- Spatial averaging correction methods and amended procedures for finite active element size.
- Instrumentation and environment
- Requirements for hydrophone types, amplifiers, cables, positioning systems, and water-bath preparation (including degassing considerations).
- Guidance on linearity, directional response, and effective hydrophone radius.
- Uncertainty and conformity
- Methods for estimating measurement uncertainty and compliance/conformity statements for reporting acoustic output.
Notable technical revisions versus earlier editions:
- Removal of the previous upper frequency limit (40 MHz).
- Hydrophone sensitivity treated as complex-valued.
- Expanded deconvolution and broadband/narrow-band procedures; updated spatial averaging correction and supporting annexes.
Applications and who uses this standard
IEC 62127-1:2022 is essential for:
- Acoustic metrology laboratories performing hydrophone-based measurements.
- Medical ultrasound manufacturers (diagnostic, therapeutic, surgical) validating transducer output.
- Regulatory bodies and test houses assessing device safety and compliance.
- Clinical engineers and research groups characterizing ultrasonic fields for device development and dosimetry studies.
Practical uses include characterizing diagnostic pulses, therapeutic fields, lithotripter outputs, and multi-mode fields where precise pressure and intensity metrics and uncertainty quantification are required.
Related standards
Refer to other parts of the IEC 62127 hydrophone series and relevant IEC medical ultrasound safety and performance standards for broader conformity and device-specific test methods.
Технические детали
- Технический комитет
- TC 87 - Ultrasonics
- SKU
- IEC 62127-1:2022
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC 62127-2:2007
ДействующийUltrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields up to 40 MHz
Overview IEC 62127-2:2007 - "Ultrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields up to 40 MHz" specifies methods for absolute and relative (comparative) calibration of hydrophones u…
IEC 62590-2-2:2026
ДействующийRailway applications - Electronic power converters for fixed installations - Part 2-2: DC Traction applicatio…
Overview IEC 62590-2-2:2026 is an international standard developed by the International Electrotechnical Commission (IEC) focusing on railway applications, specifically the electronic power converter…
IEC 61753-042-02:2026
ДействующийFibre optic interconnecting devices and passive components - Performance standard - Part 042-02: Plug-pigtail…
Overview IEC 61753-042-02:2026 establishes the minimum performance, test, and measurement requirements for plug-pigtail and plug-receptacle style OTDR (Optical Time-Domain Reflectometer) reflecting d…
IEC 61837-2:2018
ДействующийSurface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal le…
Overview IEC 61837-2:2018 - Surface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal lead connections - Part 2: Ceramic enclosures (Edition 3.0, 2018…
IEC 61851-23-1:2026
ДействующийElectric vehicle conductive charging system - Part 23-1: DC electric vehicle supply equipment - Automated con…
Overview IEC 61851-23-1:2026 is an international standard published by the International Electrotechnical Commission (IEC) that specifies requirements for DC electric vehicle supply equipment (EVSE)…
IEC 63506:2026
ДействующийCalibration of the prompt fission neutron logging tools
Overview IEC 63506:2026 - Calibration of the Prompt Fission Neutron Logging Tools is the international standard that specifies the calibration methods for prompt fission neutron (PFN) logging tools,…
IEC 63589-1:2026
ДействующийLinear accelerator - Electron linear accelerator for radiation processing - Part 1: General requirements and…
Overview IEC 63589-1:2026 specifies the general requirements and test methods for electron linear accelerator devices used in radiation processing. Developed by the International Electrotechnical Com…
IEC 61837-2:2018/AMD2:2026
ДействующийAmendment 2 - Surface mounted piezoelectric devices for frequency control and selection - Standard outlines a…
Overview IEC 61837-2:2018/AMD2:2026, published by the International Electrotechnical Commission (IEC), serves as Amendment 2 to the international standard for surface mounted piezoelectric devices us…