IEC 62386-202:2009
Digital addressable lighting interface - Part 202: Particular requirements for control gear - Self-contained emergency lighting (device type 1)
Digital addressable lighting interface - Part 202: Particular requirements for control gear - Self-contained emergency lighting (device type 1)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 215
- Дата публикации:
- 9 июня 2009 г.
- Издание:
- IEC IS 62386 edition 1 version 1
- ICS:
- 29.140.50
IEC 62386-202:2009 specifies a protocol and test procedures for the control by digital signals of electronic control gear for use on a.c. or d.c. supplies, associated with self-contained emergency lighting. This Part 202 is intended to be used in conjunction with IEC 62386-101 and IEC 62386-102, which contain general requirements for the relevant product type (control gear or control devices).
Abstract
Overview
IEC 62386-202:2009 is a critical international standard developed by the International Electrotechnical Commission (IEC) focusing on digital addressable lighting interface (DALI) systems. Specifically, Part 202 details the particular requirements for electronic control gear associated with self-contained emergency lighting (device type 1) used on both AC and DC supplies. This standard forms a key component in the wider IEC 62386 series and is designed to be used in conjunction with general requirements defined in IEC 62386-101 and IEC 62386-102.
The main purpose of IEC 62386-202:2009 is to specify digital protocols and type test procedures for emergency control gear. These ensure reliable communication, performance, and interoperability of emergency lighting systems. The standard is essential for manufacturers, system integrators, and building managers who need to guarantee safety and functionality in emergency situations.
Key Topics
-
Scope and Application
- Applicable to control gear associated with self-contained emergency lighting, operating on either AC or DC supplies.
- Defines digital signal protocols and type test procedures for emergency lighting systems.
-
Modes of Operation
- Normal Mode: Mains supply is available; batteries are charged or charging.
- Emergency Mode: Activated when mains supply fails; system runs on battery until deep discharge.
- Rest Mode: Lamp is turned off intentionally while powered by the battery.
- Inhibit Mode: Prevents system from switching to emergency mode even during mains failure.
-
Test Procedures
- Specifies mandatory type tests (not production-line tests) to verify emergency functionality.
- Includes functional and duration test requirements for self-contained emergency gear.
- Details on optional features such as automatic scheduling of tests.
-
Control Variables and Commands
- Defines control variables such as EMERGENCY LEVEL, PROLONG TIME, FEATURE SET, as well as detailed command structures for operation and testing.
- Interfaces with general control gear standards for consistent lighting system behavior.
Applications
IEC 62386-202:2009 provides practical value in a broad array of sectors where emergency lighting is critical for safety and compliance:
-
Commercial Buildings:
Ensures reliable operation of emergency lighting during power outages, supporting safe evacuation and regulatory compliance. -
Healthcare Facilities:
Guarantees continual lighting for critical areas like corridors and stairways during emergencies. -
Industrial Environments:
Facilitates centralized monitoring and testing of emergency luminaires, reducing maintenance costs and increasing safety. -
Public Infrastructure:
Enables integrated building management systems to control and monitor emergency lighting, ensuring rapid fault diagnosis and rectification. -
Manufacturing and Compliance:
Supports manufacturers in designing interoperable and compliant emergency lighting control gear, streamlining product approval processes.
Related Standards
IEC 62386-202:2009 is designed to work seamlessly with other parts of the IEC 62386 family:
- IEC 62386-101 - General requirements for digital addressable lighting interface systems.
- IEC 62386-102 - General requirements for control gear in DALI systems.
- IEC 62386 series - Covers additional device types and specialized DALI functions.
- EN 60598-2-22 - Luminaires: Emergency lighting, relevant for luminaire safety and performance.
Employing IEC 62386-202:2009 ensures higher interoperability, safety, and quality in emergency lighting systems through consistent digital control protocols and standardized testing, making it indispensable for professionals invested in reliable and compliant lighting solutions.
Технические детали
- Технический комитет
- SC 34C - Auxiliaries for lamps
- SKU
- IEC 62386-202:2009
Похожие стандарты
Стандарты, упомянутые в описании
IEC 62386-351:2025
ДействующийDigital addressable lighting interface – Part 351: Particular requirements – Control devices – Luminaire-moun…
Overview IEC 62386-351:2025 is a part of the IEC 62386 series for the digital addressable lighting interface. This particular standard specifies particular requirements for luminaire‑mounted control…
IEC 62386-101:2022
ДействующийDigital addressable lighting interface - Part 101: General requirements - System components
Overview IEC 62386-101:2022 - part of the IEC 62386 series for the Digital Addressable Lighting Interface (DALI) - specifies general requirements for system components in a bus system used to control…
IEC 62386-102:2022
ДействующийDigital addressable lighting interface - Part 102: General requirements - Control gear
Overview IEC 62386-102:2022 is Part 102 of the IEC 62386 series for the Digital Addressable Lighting Interface (DALI). This third edition defines the general requirements for control gear that are co…