IEC 62599-2:2010
Alarm systems - Part 2: Electromagnetic compatibility - Immunity requirements for components of fire and security alarm systems
Alarm systems - Part 2: Electromagnetic compatibility - Immunity requirements for components of fire and security alarm systems
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 46
- Дата публикации:
- 19 мая 2010 г.
- Издание:
- IEC IS 62599 edition 1 version 1
- ICS:
- 13.320
IEC 62599-2:2010 for immunity requirements applies to the components of the following alarm systems, intended for use in and around buildings in residential, commercial, light industrial and industrial environments: - access control systems, for security applications; - alarm transmission systems; - CCTV systems, for security applications; - fire detection and fire alarm systems; - intruder and hold-up alarm systems; - social alarm systems.
Abstract
Overview
IEC 62599-2:2010 is an international standard published by the International Electrotechnical Commission (IEC) that specifies electromagnetic compatibility (EMC) immunity requirements for the components of fire and security alarm systems. This standard is part of the IEC 62599 series focused on alarm systems, and Part 2 addresses the immunity of components against electromagnetic disturbances. It applies to alarm systems used in and around buildings in residential, commercial, light industrial, and industrial environments.
The standard particularly covers components of various alarm systems including access control, alarm transmission, CCTV for security purposes, fire detection and fire alarm, intruder and hold-up alarms, and social alarm systems. Ensuring immunity to electromagnetic interference (EMI) is critical to maintaining reliable operation and safety of these alarm systems.
Key Topics
-
Scope of Application: IEC 62599-2 applies to fire and security alarm system components installed in diverse environments such as residential dwellings, commercial buildings, and industrial sites.
-
Immunity Requirements: The standard defines specific immunity tests components must pass to withstand electromagnetic phenomena without performance degradation, thereby guaranteeing system reliability.
-
Testing Conditions and Procedures: Detailed testing methodologies for assessing immunity under various electromagnetic disturbances, including:
- Mains supply voltage variations
- Voltage dips and short interruptions
- Electrostatic discharges
- Radiated electromagnetic fields
- Conducted disturbances from electromagnetic fields
- Fast transient bursts and voltage surges
-
Compliance Criteria: Requirements establish functional performance criteria post-testing to confirm that devices maintain operational integrity under electromagnetic stresses.
-
Configuration and Operating Conditions: Test configurations and environmental parameters are standardized to ensure reproducibility and reliability of immunity assessments.
Applications
IEC 62599-2:2010 is vital for manufacturers, integrators, and testing laboratories involved in the design, production, and verification of fire and security alarm system components. Its practical applications include:
-
Product Development: Guiding design engineers to integrate electromagnetic immunity considerations from early development stages to ensure robust alarm system components.
-
Quality Assurance: Providing criteria and test methods for manufacturers to validate electromagnetic compatibility and immunity, thus minimizing malfunction risks due to EMI.
-
Regulatory Compliance: Assisting stakeholders in meeting national and international EMC regulations and certification requirements for alarm systems.
-
System Reliability: Enhancing the operational safety of fire and security alarm systems in environments susceptible to electromagnetic disturbances, ensuring timely alarms and reducing false activations.
-
Cross-sector Use: Applicable for a wide range of alarm systems employed in residential, commercial, industrial, and social care settings, ensuring broad market relevance.
Related Standards
For comprehensive electromagnetic compatibility management in alarm systems, IEC 62599-2:2010 should be referenced alongside related standards such as:
-
IEC 62599-1: Alarm systems – General requirements and tests for alarm transmission and fault warning systems.
-
IEC 61000 Series: International standards on electromagnetic compatibility testing and measurement techniques, providing foundational test methods referenced within IEC 62599-2.
-
ISO/IEC 27001: Though focused on information security, this standard complements alarm system reliability by addressing secure system management practices.
-
Local EMC Regulations: National or regional EMC directives and certifications that implement or build upon IEC standards to regulate alarm system deployments.
Keywords: IEC 62599-2, electromagnetic compatibility, EMC immunity, fire alarm systems, security alarm systems, alarm system components, electromagnetic interference immunity, IEC standards, alarm transmission, access control, CCTV security, intruder alarms, social alarm systems, electrical testing standards, fire safety systems.
Технические детали
- Технический комитет
- TC 79 - Alarm and electronic security systems
- SKU
- IEC 62599-2:2010
Похожие стандарты
Стандарты, упомянутые в описании
IEC 62599-1:2010
ДействующийAlarm systems - Part 1: Environmental test methods
Overview IEC 62599-1:2010 - Alarm systems: Part 1 Environmental test methods specifies environmental test methods used to assess the durability and functional performance of alarm-system components i…
IEC 61000-6-2:2016
ДействующийElectromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environm…
Overview IEC 61000-6-2:2016 is the third-edition generic EMC immunity standard for industrial environments published by the IEC. It defines immunity requirements for electrical and electronic equipme…