IEC 80601-2-71:2015
Medical electrical equipment - Part 2-71: Particular requirements for the basic safety and essential performance of functional near-infrared spectroscopy (NIRS) equipment
Medical electrical equipment - Part 2-71: Particular requirements for the basic safety and essential performance of functional near-infrared spectroscopy (NIRS) equipment
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 37
- Дата публикации:
- 9 июня 2015 г.
- Издание:
- IEC IS 80601 edition 1 version 1
- ICS:
- 11.040.55
IEC 80601-2-71:2015 applies to the basic safety and essential performance of functional NIRS equipment intended to be used by themselves, or as a part of an ME system, for the production of functional NIRS equipment output for adjunctive diagnostic purposes, hereinafter referred to as ME equipment.
Abstract
Overview
IEC 80601-2-71:2015 - "Medical electrical equipment - Part 2-71: Particular requirements for the basic safety and essential performance of functional near‑infrared spectroscopy (NIRS) equipment" - defines safety and performance requirements for functional NIRS equipment (often abbreviated as fNIRS). The standard applies to fNIRS devices used alone or as part of a medical electrical (ME) system to produce functional NIRS outputs for adjunctive diagnostic purposes. It sets out test methods, performance verification and essential documentation needed to demonstrate basic safety and essential performance of NIRS medical electrical equipment.
Key Topics and Requirements
- Scope & exclusions: Clarifies what is covered and what is not - for example, it excludes NIRS tissue oximeters not intended for functional output, pulse oximeters (see ISO 80601-2-61), frequency‑domain/time‑domain systems that require different tests, and devices measuring chromophores beyond oxy-/deoxy‑haemoglobin.
- Safety & performance structure: Builds on IEC 60601‑1 general requirements for ME equipment and provides particular requirements specific to functional NIRS devices.
- Electrical and mechanical protection: Requirements for protection against electrical hazards, mechanical hazards, excessive temperatures and unwanted radiation.
- Optical performance and measurements: Defines optical tests and metrics referenced in figures and tables - e.g., spectral power distribution (FWHM), average optical power, peak wavelength, signal stability, response time, rise/fall time, signal‑to‑noise ratio, and signal cross‑talk.
- Performance testing tools: Normative and informative annexes include a FUNCTIONAL NIRS PHANTOM (Annex BB) and guidance for using phantoms/attenuators to evaluate ME equipment performance.
- Identification, marking, documentation: Labelling requirements, instructions for use, and accompanying documents to support safe clinical use.
- Programmable systems & EMC: Requirements for programmable electrical medical systems (PEMS) and electromagnetic compatibility testing for ME equipment and ME systems.
Practical Applications - Who Uses This Standard
- Manufacturers of functional NIRS/fNIRS devices for design, risk management, verification and regulatory submissions.
- Regulatory and compliance teams preparing technical files and conformity assessments for markets that reference IEC standards.
- Test laboratories and certification bodies executing the standard’s test methods (including phantom‑based performance tests).
- Biomedical and clinical engineers, procurement specialists and hospital technology managers specifying safe, compliant fNIRS systems for research and adjunctive diagnostics.
- R&D teams developing new NIRS hardware and systems that must meet IEC 80601‑2‑71 safety and performance expectations.
Related Standards
- IEC 60601‑1 - General requirements for basic safety and essential performance of medical electrical equipment (collateral).
- ISO/IEC references and collateral standards cited in the standard (see Clause 2); ISO 80601‑2‑61 applies to pulse oximeters (not covered here).
This standard is essential for ensuring that functional NIRS equipment meets internationally accepted safety, performance and testing practices for clinical and research environments.
Технические детали
- Технический комитет
- SC 62D - Particular medical equipment, software, and systems
- SKU
- IEC 80601-2-71:2015
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
ISO 80601-2-61:2026
ДействующийMedical electrical equipment — Part 2-61: Particular requirements for basic safety and essential performance…
Overview ISO 80601-2-61:2026 is an international standard that specifies particular requirements for the basic safety and essential performance of pulse oximeter equipment intended for human use. Pul…
IEC 60601-1-12:2014
ДействующийMedical electrical equipment - Part 1-12: General requirements for basic safety and essential performance - C…
Overview IEC 60601-1-12:2014 is an international collateral standard under the IEC 60601-1 series, developed by the International Electrotechnical Commission (IEC). This standard sets forth general r…
IEC 62590-2-2:2026
ДействующийRailway applications - Electronic power converters for fixed installations - Part 2-2: DC Traction applicatio…
Overview IEC 62590-2-2:2026 is an international standard developed by the International Electrotechnical Commission (IEC) focusing on railway applications, specifically the electronic power converter…
IEC 61753-042-02:2026
ДействующийFibre optic interconnecting devices and passive components - Performance standard - Part 042-02: Plug-pigtail…
Overview IEC 61753-042-02:2026 establishes the minimum performance, test, and measurement requirements for plug-pigtail and plug-receptacle style OTDR (Optical Time-Domain Reflectometer) reflecting d…
IEC 61837-2:2018
ДействующийSurface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal le…
Overview IEC 61837-2:2018 - Surface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal lead connections - Part 2: Ceramic enclosures (Edition 3.0, 2018…
IEC 61851-23-1:2026
ДействующийElectric vehicle conductive charging system - Part 23-1: DC electric vehicle supply equipment - Automated con…
Overview IEC 61851-23-1:2026 is an international standard published by the International Electrotechnical Commission (IEC) that specifies requirements for DC electric vehicle supply equipment (EVSE)…
IEC 63506:2026
ДействующийCalibration of the prompt fission neutron logging tools
Overview IEC 63506:2026 - Calibration of the Prompt Fission Neutron Logging Tools is the international standard that specifies the calibration methods for prompt fission neutron (PFN) logging tools,…
IEC 63589-1:2026
ДействующийLinear accelerator - Electron linear accelerator for radiation processing - Part 1: General requirements and…
Overview IEC 63589-1:2026 specifies the general requirements and test methods for electron linear accelerator devices used in radiation processing. Developed by the International Electrotechnical Com…