ISO 10313:1993
Ambient air — Determination of the mass concentration of ozone — Chemiluminescence method
Ambient air — Determination of the mass concentration of ozone — Chemiluminescence method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 9
- Дата публикации:
- 22 апреля 1993 г.
- Издание:
- ISO IS 10313 edition 1 version 1
- ICS:
- 13.040.20
The method specified is based on drawing continuously, at a constant flow rate, an air sample through a particle filter before it enters the chemiluminescence analyser. It then flows into a reaction chamber where it is mixed with an excess flow of ethylene. Ozone and ethylene react instantaneously to produce light in the visible region (maximum at about 400 nm). The emitted light intensity is proportional to the concentration of ozone in the air sample and is measured by a photomultiplier tube. Applies to determination of the mass concentration of ozone between 2 µg/m^3 and 10 mg/m^3 at the reference conditions.
Abstract
Overview
ISO 10313:1993 - Ambient air: Determination of the mass concentration of ozone - Chemiluminescence method specifies a standardized chemiluminescence technique for measuring ozone in ambient air. The method draws a continuous, constant-flow air sample through a particle filter into a reaction chamber where it mixes with excess ethylene. Ozone + ethylene react instantly to emit visible light (maximum near 400 nm); the emitted light, measured by a photomultiplier, is proportional to ozone concentration. The standard applies to mass concentrations from 2 µg/m³ to 10 mg/m³ at reference conditions (25 °C, 101.3 kPa).
Key topics and technical requirements
- Measurement principle: chemiluminescence (ozone + ethylene → visible emission ≈ 400 nm) with photomultiplier detection.
- Calibration: ultraviolet (UV) photometry (primary method) using a low‑pressure mercury lamp (253.7 nm) is specified for primary calibration. Transfer standards may be used if annually traceable to the UV standard.
- Sampling system:
- Particle filter (ozone‑inert materials such as fluorocarbon polymer) to prevent particulate-induced ozone loss or optical scattering.
- Sampling line of ozone‑inert material (glass or fluorocarbon polymer) kept as short as possible; recommended residence time <0.5 s (routine up to 5 s).
- Reagents & gases:
- Ethylene of minimum purity 99.5% for the chemiluminescent reaction.
- Zero air used for calibration must be free of ozone and NOx; if synthetic air is used its oxygen content should be within ±2% of 20.9%.
- Apparatus: chemiluminescence analyser with reaction chamber, photomultiplier, signal processing electronics, flowmeters and pumps; ozone generator and UV photometer for calibration systems.
- Performance & quality:
- Overall precision for generation and UV-photometric measurement better than ±5% (UV-photometric calibrations can be within ±1% with careful operation).
- Recommended multipoint calibration every 3 months; routine zero/span checks (weekly).
- Safety notes: Ethylene is flammable (lower explosive limit noted in the standard). Ozone is toxic - excess exhaust must be vented or scrubbed.
Practical applications
- Ambient air quality monitoring networks for regulatory compliance and trend assessment.
- Field and laboratory ozone measurement, instrument validation and intercomparisons.
- Calibration and service laboratories using transfer standards or primary UV photometric systems.
- Research studies requiring accurate ozone concentration data (health, atmospheric chemistry, exposure assessment).
Who uses this standard
- Environmental and air quality monitoring agencies
- Calibration laboratories and instrument manufacturers
- Field technicians and researchers conducting ambient ozone measurements
- Quality managers establishing traceable ozone measurement programs
Related standards
- Other ISO air‑quality standards and guidance produced by ISO/TC 146 (Air quality, Sub‑Committee SC 3 - Ambient atmospheres) and methods referenced for calibration and zero‑air generation (see ISO 10313 annexes).
Технические детали
- Технический комитет
- ISO/TC 146/SC 3 - Ambient atmospheres
- SKU
- ISO 10313:1993
Похожие стандарты
Другие стандарты ISO
ISO 8212:1986
ОтменёнSoaps and detergents — Techniques of sampling during manufacture
Overview Standard Reference: ISO 8212:1986 Title: Soaps and detergents - Techniques of sampling during manufacture ISO 8212:1986 defines standardized techniques for taking representative samples of s…
ISO 20662:2020
ДействующийShips and marine technology — Hopper dredger supervisory and control systems
Overview ISO 20662:2020 - Ships and marine technology: Hopper dredger supervisory and control systems (HD‑SCS) - specifies the components, structure, general requirements, and functional requirements…
ISO 3021:2023
ДействующийAdventure tourism — Hiking and trekking activities — Requirements and recommendations
Overview ISO 3021:2023 - Adventure tourism: Hiking and trekking activities - Requirements and recommendations defines safety-focused requirements and recommendations for hiking and trekking offered a…
ISO 3826-2:2008
ДействующийPlastics collapsible containers for human blood and blood components — Part 2: Graphical symbols for use on l…
Overview ISO 3826-2:2008 - "Plastics collapsible containers for human blood and blood components - Part 2: Graphical symbols for use on labels and instruction leaflets" defines a system of internatio…
ISO/IEC 24730-1:2014
ДействующийInformation technology — Real-time locating systems (RTLS) — Part 1: Application programming interface (API)
Overview ISO/IEC 24730-1:2014 specifies the Application Programming Interface (API) for Real‑Time Locating Systems (RTLS). The standard defines a minimal, interoperable boundary that lets application…
ISO 8668-5:1992
ДействующийAircraft — Terminal junction systems — Part 5: Detail specification for type 3 system
Overview - ISO 8668-5:1992 (Aircraft terminal junction systems, Type 3) ISO 8668-5:1992 defines the detail specification for Type 3 Terminal Junction Systems (TJS) used in aircraft electrical install…
ISO 7574-3:1985
ДействующийAcoustics — Statistical methods for determining and verifying stated noise emission values of machinery and e…
Overview ISO 7574-3:1985 is part of the ISO 7574 series on acoustics and provides a simple (transition) statistical method for determining and verifying stated noise emission values for batches (lots…
ISO 15638-15:2014
ДействующийIntelligent transport systems — Framework for cooperative telematics applications for regulated vehicles (TAR…
Overview - ISO 15638-15:2014 (Vehicle location monitoring, TARV) ISO 15638-15:2014 is part of the ISO 15638 suite for Intelligent Transport Systems (ITS) and defines the framework and data specificat…