ISO 11114-3:2010
Gas cylinders — Compatibility of cylinder and valve materials with gas contents — Part 3: Autogenous ignition test for non-metallic materials in oxygen atmosphere
Gas cylinders — Compatibility of cylinder and valve materials with gas contents — Part 3: Autogenous ignition test for non-metallic materials in oxygen atmosphere
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 7
- Дата публикации:
- 1 декабря 2010 г.
- Издание:
- ISO IS 11114 edition 2 version 1
- ICS:
- 23.020.30
ISO 11114-3:2010 specifies a test method to determine the autogenous ignition temperature of non-metallic materials in pressurized gaseous oxygen. The autogenous ignition temperature is one criterion for ranking materials, and can be used to assist with the choice of materials used in the presence of gaseous oxygen. A comprehensive bibliography of the published material on which ISO 11114-3:2010 is based is included. It is intended that ISO 11114-3:2010 be used for the selection of non-metallic materials for gas cylinders and accessories, for example to select the materials in order to meet the requirement for type testing for oxygen compatibility of all cylinder valves for highly oxidizing gases as specified in ISO 10297.
Abstract
Overview
ISO 11114-3:2010 specifies an autogenous ignition test for determining the ignition behavior of non‑metallic materials in pressurized gaseous oxygen. The standard defines how to measure the autogenous ignition temperature - the temperature at which a sudden, self‑sustaining increase in temperature and pressure occurs - and provides test procedures, apparatus guidance and reporting requirements. ISO 11114-3 is intended to help rank and select materials for oxygen compatibility in gas cylinders, valves and accessories, and to support type testing requirements (for example ISO 10297 for cylinder valves).
Key topics and technical requirements
- Test principle: heat a small quantity of test material in a sealed reaction chamber filled with pressurized oxygen and continuously record temperature and pressure to identify the autogenous ignition point.
- Sample preparation: liquids or finely divided solids; sample mass typically 0.06 g to 0.5 g (examples use 0.3–0.5 g), adjusted for chamber volume.
- Reaction chamber size: practical chamber volumes quoted in the standard range 30 cm³ to 250 cm³.
- Oxygen purity: minimum 99.5% by volume; hydrocarbon content limited (see standard).
- Pressure: autogenous ignition temperature depends on oxygen pressure; for ranking the standard recommends a starting pressure of 100 bar when minimum ignition temperature is required.
- Instrumentation:
- Thermocouple close to sample with accuracy ±2 °C (25–500 °C).
- Pressure transducer accuracy 1% full scale.
- Heating: temperature raised at a constant rate; typical heating rates are 5–20 °C/min (high rates >20 °C/min may lower measured ignition temperature). Maximum test temperature 500 °C.
- Results: autogenous ignition temperature is taken where a sudden increase in both temperature and pressure begins; ΔT and Δp quantify reaction severity.
- Safety: apparatus and chamber must withstand violent internal reactions; purge procedure (pressurize to 10 bar then vent, repeated three times) to remove air.
Applications
- Material selection and ranking for oxygen service (seals, gaskets, lubricants, polymers) used in gas cylinders, valves and oxygen systems.
- Type testing to demonstrate oxygen compatibility of cylinder valves and accessories (supporting ISO 10297 compliance).
- Test laboratories providing oxygen‑compatibility data for manufacturers, safety assessments, and risk management.
Who uses this standard
- Cylinder and valve manufacturers
- Materials engineers and product designers for oxygen systems
- Accredited testing laboratories
- Safety and compliance officers in medical, industrial and aerospace gas supply sectors
Related standards
- ISO 11114-1, ISO 11114-2, ISO 11114-4 (other parts on materials and hydrogen embrittlement)
- ISO 10297 (cylinder valve type testing)
- ISO 4589-3 (oxygen index tests) and ISO 21010 (cryogenic gas/materials compatibility)
Keywords: ISO 11114-3, autogenous ignition test, oxygen compatibility, gas cylinders, non‑metallic materials, autogenous ignition temperature, ISO 10297.
Технические детали
- Технический комитет
- ISO/TC 58 - Gas cylinders
- SKU
- ISO 11114-3:2010
Похожие стандарты
Стандарты, упомянутые в описании
BS EN ISO 11114-3:2010
ДействующийGas cylinders. Compatibility of cylinder and valve materials with gas contents. Autogenous ignition test for…
BS EN ISO 10297:2024
ДействующийGas cylinders. Cylinder valves. Specification and type testing.
ISO 11114-1:2020
ДействующийGas cylinders — Compatibility of cylinder and valve materials with gas contents — Part 1: Metallic materials
Overview ISO 11114-1:2020 is an international standard developed by ISO that specifies the requirements for the selection and safe use of metallic cylinder and valve materials in contact with gas con…
BS EN ISO 11114-2:2021
ДействующийGas cylinders. Compatibility of cylinder and valve materials with gas contents. Non-metallic materials.
BS EN ISO 11114-4:2017
ДействующийTransportable gas cylinders. Compatibility of cylinder and valve materials with gas contents. Test methods fo…
ISO 4589-3:2017
ДействующийPlastics — Determination of burning behaviour by oxygen index — Part 3: Elevated-temperature test
Overview ISO 4589-3:2017 - "Plastics - Determination of burning behaviour by oxygen index - Part 3: Elevated‑temperature test" - specifies laboratory methods to determine the minimum oxygen concentra…