ISO 11296-2:2018
Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks — Part 2: Lining with continuous pipes
Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks — Part 2: Lining with continuous pipes
- Статус документа:
- Отменён
- Формат:
- Электронный (PDF)
- Количество страниц:
- 8
- Дата публикации:
- 24 января 2018 г.
- Издание:
- ISO IS 11296 edition 1 version 1
- ICS:
- 23.040.20
ISO 11296-2:2018, in conjunction with ISO 11296-1, specifies requirements and test methods for pipes and fittings which are part of plastics piping systems installed as continuous pipes in the renovation of underground non-pressure drainage and sewerage networks. It is applicable to polyethylene (PE) pipes of three different types: - PE solid wall single layered pipes (nominal outside diameter, dn), including any identification stripes; - PE pipes with co-extruded layers on either or both the outside and inside of the pipe (total outside diameter, dn), as specified in Annex A, where all layers have the same MRS rating; - PE coated pipes (outside diameter, dn) having a peelable, contiguous, thermoplastics additional layer on the outside of the pipe ("coated pipe"), see Annex A. In addition, ISO 11296-2:2018 covers: - jointing of pipe lengths by means of butt fusion; - fabricated and injection-moulded fittings made of PE.
Abstract
Overview
ISO 11296-2:2018 - "Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 2: Lining with continuous pipes" defines requirements and test methods for polyethylene (PE) continuous pipe lining used to renovate underground non-pressure drainage and sewerage systems. Used together with ISO 11296-1 (General), it specifies material, geometric, mechanical and physical characteristics of pipes and fittings, jointing practice and site verification for systems installed as continuous pipes.
Key topics and requirements
- Scope: Applies to three PE pipe types:
- Solid wall single-layer PE pipes (dn),
- PE pipes with co-extruded layers (all layers with same MRS, Annex A),
- PE coated pipes with a peelable thermoplastic outer layer (Annex A).
- Material and performance: Pipes must conform to PE material and property requirements referenced to ISO 8772.
- Jointing: Jointing of pipe lengths is by butt fusion; fittings include fabricated and injection‑moulded PE components. All butt fusions are to be externally de‑beaded and, if required, internally de‑beaded.
- Marking and identification: Pipes and coatings must be marked per ISO 11296-1 or ISO 8772; coated pipes should be clearly distinguishable in service (e.g., colour bands).
- Installation and site verification: Covers preparatory work, handling, equipment (butt‑fusion and electrofusion units, de‑beading tools, pipe rollers, winching/rod-pulling, entry guides, inspection and lifting equipment), installation procedures, process-related inspection/testing, lining termination and reconnection, and final documentation.
- Stages of assessment: Addresses verification of characteristics both “as manufactured” (M stage) and “as installed” (I stage) to ensure fitness for purpose after site processing.
Applications and practical value
- Renovation (rehabilitation) of underground non‑pressure drainage and sewerage pipelines using continuous PE pipe lining techniques.
- Typical users:
- Municipal utilities and wastewater asset owners specifying rehabilitation works.
- Engineering and design consultants preparing project specifications.
- Pipe manufacturers and lining contractors who must meet material, jointing and installation requirements.
- Quality assurance inspectors and test laboratories performing site verification and acceptance testing.
- Practical benefits: Provides a harmonized framework for material selection, jointing practice (butt fusion), installation equipment, and post‑installation verification - reducing project risk and improving long‑term performance of renewed sewerage networks.
Related standards
- ISO 11296-1:2018 (General requirements)
- ISO 8772 (PE piping for non-pressure drainage and sewerage)
- ISO 12176-1 / ISO 12176-2 (fusion equipment - butt fusion, electrofusion)
- EN 12666-1 and other parts of the ISO 11296 series (Parts 3–10 cover alternative lining methods)
Keywords: ISO 11296-2:2018, plastics piping systems, continuous pipe lining, polyethylene (PE), butt fusion, sewerage network renovation, non-pressure drainage.
Технические детали
- Технический комитет
- ISO/TC 138/SC 8 - Rehabilitation of pipeline systems
- SKU
- ISO 11296-2:2018
Похожие стандарты
Стандарты, упомянутые в описании
ISO 11296-1:2018
ДействующийPlastics piping systems for renovation of underground non-pressure drainage and sewerage networks — Part 1: G…
Overview ISO 11296-1:2018 - Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 1: General. This ISO standard sets out the general requirements an…
ISO 8772:2006
ДействующийPlastics piping systems for non-pressure underground drainage and sewerage — Polyethylene (PE)
Overview ISO 8772:2006 specifies requirements for polyethylene (PE) pipes, fittings and piping systems for non-pressure underground drainage and sewerage. It applies to buried pipework (including pip…
BS ISO 12176-1:2017
ДействующийPlastics pipes and fittings. Equipment for fusion jointing polyethylene systems. Butt fusion.
ISO 12176-2:2008
ОтменёнPlastics pipes and fittings — Equipment for fusion jointing polyethylene systems — Part 2: Electrofusion
Overview ISO 12176-2:2008 specifies performance and construction requirements for electrofusion control units used to join polyethylene (PE) pipes and fittings. The standard applies to control units…
BS EN 12666-1:2026
ДействующийPlastics piping systems for non-pressure underground drains and sewers. Polyethylene (PE). Specifications for…
ISO 11296-4:2018
ДействующийPlastics piping systems for renovation of underground non-pressure drainage and sewerage networks — Part 4: L…
Overview ISO 11296-4:2018 specifies requirements and test methods for cured‑in‑place pipes (CIPP) used to renovate underground non‑pressure drainage and sewerage networks. Intended to be used togethe…