ISO 11904-1:2002
Acoustics — Determination of sound immission from sound sources placed close to the ear — Part 1: Technique using a microphone in a real ear (MIRE technique)
Acoustics — Determination of sound immission from sound sources placed close to the ear — Part 1: Technique using a microphone in a real ear (MIRE technique)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 20
- Дата публикации:
- 10 октября 2002 г.
- Издание:
- ISO IS 11904 edition 1 version 1
- ICS:
- 13.140
ISO 11904-1:2002 specifies basic framework measurement methods for sound immissions from sound sources placed close to the ear. These measurements are carried out with miniature or probe microphones inserted in the ear canals of human subjects. The measured values are subsequently converted into corresponding free-field or diffuse-field levels. The results can be given as free-field related or diffuse-field related equivalent continuous A-weighted sound pressure levels. The technique is denoted the microphone-in-real-ear technique (MIRE technique). ISO 11904-1:2002 is applicable to exposure from sources close to the ear, for example during equipment tests or at the workplace by earphones or hearing protectors with audio communication facilities. ISO 11904-1:2002 is applicable in the frequency range from 20 Hz to 16 000 Hz.
Abstract
Overview
ISO 11904-1:2002 - "Acoustics - Determination of sound immission from sound sources placed close to the ear - Part 1: Technique using a microphone in a real ear (MIRE technique)" - defines a standardized method for measuring sound exposure when the source is close to the ear. The standard uses miniature/probe microphones inserted in human ear canals (the MIRE technique) to measure ear-canal sound pressure, then converts those readings into corresponding free-field or diffuse-field related equivalent continuous A‑weighted sound pressure levels. Applicable frequency range: 20 Hz to 16 000 Hz.
Key topics and technical requirements
- Measurement principle: direct ear-canal measurement with probe microphones and conversion to free-field or diffuse-field levels so results can be compared with established exposure criteria.
- Instrumentation: specifications and checks for ear-canal microphones, reference field microphones, filters and calibration procedures.
- Subjects and safety: selection of human subjects, ear-canal measurement positions, safe mounting of probes and positioning considerations.
- Conversion & weighting: methods to convert measured ear-canal sound pressure to free-field or diffuse-field related sound pressure levels; application of A-weighting and summation to produce equivalent continuous A-weighted levels (Leq, A).
- Frequency responses: procedures for determining human free-field and diffuse-field frequency responses and deriving banded corrections.
- Uncertainty and reporting: requirements for test reporting and informative annexes (Annex A and B) giving examples of measurement uncertainty analysis.
Applications and who uses it
ISO 11904-1 is used where conventional field measurements (with the person absent) do not accurately represent ear exposure because the source is near the ear. Typical use cases:
- Testing and certification of headphones, earphones and in-ear devices
- Assessment of hearing protectors with communication systems
- Workplace noise exposure evaluations for close-to-ear sources (e.g., portable audio equipment, certain tools)
- Product development and verification for consumer audio and professional communication headsets
- Occupational hygienists, acoustic laboratories, manufacturers, and regulatory bodies performing noise compliance, hearing conservation, and safety testing
Practical value
- Produces representative, human-based measures of ear exposure using the MIRE technique, enabling accurate assessments against occupational noise limits and design requirements.
- Converts ear-canal data to commonly used reference levels (free-field/diffuse-field) for compatibility with other standards and regulations.
Related standards
- ISO 11904-2 (manikin technique)
- ISO 8253-2, IEC 60268-7, IEC 60942 and related IEC/ISO documents referenced for instrumentation, calibration and audiometric practices.
Keywords: ISO 11904-1:2002, MIRE technique, microphone-in-real-ear, acoustics standard, sound immission, ear canal measurements, free-field related A-weighted, diffuse-field, workplace noise assessment, headphones testing.
Технические детали
- Технический комитет
- ISO/TC 43 - Acoustics
- SKU
- ISO 11904-1:2002
Похожие стандарты
Стандарты, упомянутые в описании
BS EN ISO 11904-1:2002
ДействующийAcoustics. Determination of sound immission from sound sources placed close to the ear.. Technique using a mi…
ISO 11904-2:2004
ОтменёнAcoustics — Determination of sound immission from sound sources placed close to the ear — Part 2: Technique u…
ISO 8253-2:2009
ДействующийAcoustics — Audiometric test methods — Part 2: Sound field audiometry with pure-tone and narrow-band test sig…
Overview ISO 8253-2:2009 - Acoustics: Audiometric test methods - Part 2 defines requirements and procedures for sound field audiometry using pure tones, frequency‑modulated (FM) tones, and narrow‑ban…
IEC 60268-7:2025
ДействующийSound system equipment - Part 7: Headphones and earphones
Overview IEC 60268-7:2025 - Sound system equipment - Part 7: Headphones and earphones - is the 4th edition international standard that defines characteristics, classification and measurement methods…
IEC 60942:2017
ДействующийElectroacoustics - Sound calibrators
Overview IEC 60942:2017 - Electroacoustics - Sound calibrators defines performance, test and documentation requirements for portable and laboratory sound calibrators used to generate a known sound pr…