ISO 8253-2:2009
Acoustics — Audiometric test methods — Part 2: Sound field audiometry with pure-tone and narrow-band test signals
Acoustics — Audiometric test methods — Part 2: Sound field audiometry with pure-tone and narrow-band test signals
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 16
- Дата публикации:
- 10 декабря 2009 г.
- Издание:
- ISO IS 8253 edition 2 version 1
- ICS:
- 13.140
ISO 8253-2:2009 specifies relevant test signal characteristics, requirements for free, diffuse, and quasi‑free sound fields, and procedures for sound field audiometry using pure tones, frequency-modulated tones or other narrow-band test signals presented by means of one or more loudspeakers. The primary purpose is the determination of hearing threshold levels in the frequency range 125 Hz to 8 000 Hz, but this range can be extended to 20 Hz to 16 000 Hz. ISO 8253-2:2009 does not include specifications for the use of hand-held loudspeakers. Speech as a test signal is not covered. The purpose of ISO 8253-2:2009 is to ensure that tests of hearing, using sound field audiometry, give as high a degree of accuracy and reproducibility as possible. Examples of graphical representations of the results are given.
Abstract
Overview
ISO 8253-2:2009 - Acoustics: Audiometric test methods - Part 2 defines requirements and procedures for sound field audiometry using pure tones, frequency‑modulated (FM) tones, and narrow‑band test signals presented via one or more loudspeakers. Its primary purpose is determination of hearing threshold levels in the frequency range 125 Hz to 8 000 Hz (extendable to 20 Hz–16 000 Hz). The standard specifies test signal characteristics, requirements for free, diffuse, and quasi‑free sound fields, calibration and reporting conventions, and procedures to maximize accuracy and reproducibility of sound‑field hearing tests. It excludes hand‑held loudspeakers and speech test signals.
Key Topics and Requirements
- Test signals
- Allowed signals: pure tones (in appropriate fields), FM tones, and narrow‑band noise.
- Pure tones: used only in a free sound field to avoid standing‑wave errors.
- FM tones: defined by carrier frequency, modulating waveform (sinusoidal or triangular), repetition rate and frequency deviation - these parameters must be reported.
- Narrow‑band noise: centre frequency and bandwidth must comply with IEC 60645‑1 masking noise specifications.
- Sound fields
- Free sound field: negligible room boundary effects (required for pure tones).
- Diffused field: statistically uniform energy density and random propagation directions.
- Quasi‑free field: moderate boundary effects with specified tolerances.
- Frequency range & tolerances
- Nominal audiometric frequencies per IEC 60645‑1 / ISO 266; frequency tolerances and FM modulation tolerances are defined for reproducibility.
- Room and equipment
- Ambient noise limits in the test room, calibration methods, and scales for measurement are addressed.
- Maintenance and calibration regimes (routine listening checks to periodic electroacoustic and basic calibration tests) are specified.
- Procedures & reporting
- Methods for threshold determination (monaural, binaural), testing with hearing aids (functional gain), screening audiometry, and standardized reporting (including graphical displays, Annex A).
Applications - Who Uses It
- Audiologists and clinical hearing professionals for clinical sound‑field testing (especially pediatric assessments and aided listening tests).
- Hearing‑aid manufacturers and dispensers to measure functional gain in the sound field.
- Acoustic engineers and test‑room designers ensuring test environments meet free/diffuse field criteria.
- Research labs and regulatory bodies applying standardized audiometric methods for reproducible results.
Practical benefits include improved accuracy, repeatability of thresholds, and consistent measurement of hearing‑aid performance in real listening environments.
Related Standards (normative references)
- ISO 8253‑1: Basic pure‑tone air and bone conduction audiometry
- ISO 8253‑3: Speech audiometry (related part)
- ISO 226, ISO 266, ISO 389‑7
- IEC 60645‑1 (audiometers), IEC 61672‑1 (sound level meters), IEC 60581‑7 (loudspeaker performance)
Keywords: ISO 8253-2:2009, sound field audiometry, audiometric test methods, pure-tone, FM tones, narrow-band noise, hearing threshold, calibration, free field, diffuse field, functional gain.
Технические детали
- Технический комитет
- ISO/TC 43 - Acoustics
- SKU
- ISO 8253-2:2009
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60645-1:2017
ДействующийElectroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry
Overview IEC 60645-1:2017 - "Electroacoustics - Audiometric equipment - Part 1: Equipment for pure‑tone and speech audiometry" is an international standard that specifies general technical and perfor…
ISO 26683-3:2019
ДействующийIntelligent transport systems — Freight land conveyance content identification and communication — Part 3: Mo…
Overview - ISO 26683-3:2019 at a glance ISO 26683-3:2019, part of the ISO 26683 series on intelligent transport systems - freight land conveyance, defines requirements for monitoring cargo condition…
ISO 8253-1:2010
ДействующийAcoustics — Audiometric test methods — Part 1: Pure-tone air and bone conduction audiometry
Overview - ISO 8253-1:2010 (Pure‑tone air and bone conduction audiometry) ISO 8253-1:2010 specifies internationally harmonized procedures and requirements for conducting pure‑tone air conduction and…
ISO 8253-3:2012
ОтменёнAcoustics — Audiometric test methods — Part 3: Speech audiometry
ISO 22628:2002
ДействующийRoad vehicles — Recyclability and recoverability — Calculation method
Overview ISO 22628:2002 specifies a standardized calculation method for the recyclability and recoverability rates of new road vehicles. Expressed as mass fractions (percent by mass), these rates est…
ISO 389-7:2005
ОтменёнAcoustics — Reference zero for the calibration of audiometric equipment — Part 7: Reference threshold of hear…
IEC 61672-1:2013
ДействующийElectroacoustics - Sound level meters - Part 1: Specifications
Overview IEC 61672-1:2013 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the performance requirements for sound level meters used in elec…