ISO 1516:2002
Determination of flash/no flash — Closed cup equilibrium method
Determination of flash/no flash — Closed cup equilibrium method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 9
- Дата публикации:
- 7 марта 2002 г.
- Издание:
- ISO IS 1516 edition 3 version 1
- ICS:
- 75.080
This International Standard specifies a method to determine if paints, varnishes, paint binders, solvents, petroleum or related products, when maintained at a selected equilibrium temperature and under the conditions of the test, give off sufficient flammable vapour to cause ignition on application of an external source of flame applied in a standard manner. This International Standard is not applicable to water-borne paints which may, however, be tested using ISO 3680. The method is suitable for use over the temperature range -30 °C to 110 °C, depending on the use of different apparatus listed in Table 1. The interpretation of results obtained from solvent mixtures containing halogenated hydrocarbons, should be considered with caution, as these mixtures can give anomalous results.
Abstract
Overview
ISO 1516:2002 - "Determination of flash/no flash - Closed cup equilibrium method" specifies a standardized test to determine whether paints, varnishes, paint binders, solvents, petroleum and related liquids produce sufficient flammable vapour at a selected equilibrium temperature to ignite when exposed to a standard external flame. This is a pass/no‑pass test (flash/no flash), not a measurement of the exact flash point. The method covers test temperatures from −30 °C to 110 °C depending on the closed‑cup apparatus used and warns that solvent mixtures containing halogenated hydrocarbons can give anomalous results.
Key topics and technical requirements
- Test principle: A test portion is equilibrated in a closed cup in a thermostatted bath; after at least 10 minutes at the selected temperature, a small ignition flame is introduced and the presence or absence of ignition is recorded.
- Apparatus:
- Closed cup and lid with sliding opening and ignition device; flame diameter 3–4 mm.
- Thermostated bath capable of maintaining temperature to ±0.5 °C.
- Test cup thermometer and bath thermometer with required accuracy.
- Barometer accurate to 0.1 kPa for pressure recording and temperature correction.
- Temperature ranges by apparatus (typical):
- Procedure details:
- Equilibration for a minimum period (typically ≥10 min) before ignition trial.
- Ignition operation must be performed within 2–3 seconds (open, position flame, remove, close).
- Barometric correction for test temperature: T_corrected = T_selected − 0.25 × (101.3 − p) (valid approximately between 98.0 and 104.7 kPa).
- Quality and verification: Annual apparatus verification using certified reference materials (CRM) per ISO 1523; more frequent checks recommended with secondary working standards.
Applications and users
ISO 1516:2002 is used for:
- Regulatory and safety assessments for storage, handling and transport of flammable paints, solvents and petroleum products.
- Quality control and incoming inspection in coatings, chemical and petrochemical manufacturing.
- Preparation of safety data sheets (SDS) and risk assessments where pass/no‑pass behaviour at storage temperatures is required. Primary users: test laboratories, manufacturers of paints/solvents/fuels, regulatory agencies, safety officers and compliance teams.
Related standards
- ISO 1523 - Determination of flash point (closed cup equilibrium method; apparatus verification)
- ISO 3680 - Alternative closed‑cup equilibrium method (for water‑borne paints)
- ISO 2719, ISO 13736, ASTM D56 - Other closed‑cup and tag test methods
- ISO 15528, ISO 3170, ISO 3171, ISO 1513 - Sampling and sample preparation standards
Keywords: ISO 1516:2002, flash/no flash, closed cup equilibrium method, flash point, paints, varnishes, solvents, petroleum, thermostated bath, apparatus verification, barometric correction.
Технические детали
- Технический комитет
- ISO/TC 28 - Petroleum and related products, fuels and lubricants from natural or synthetic sources
- SKU
- ISO 1516:2002
Похожие стандарты
Стандарты, упомянутые в описании
ISO 2719:2016
ОтменёнDetermination of flash point — Pensky-Martens closed cup method
Overview ISO 2719:2016 - Determination of flash point: Pensky‑Martens closed cup method specifies three test procedures (A, B and C) for measuring the flash point of combustible liquids using a Pensk…
ISO 13736:2021
ДействующийDetermination of flash point — Abel closed-cup method
Overview ISO 13736:2021 - "Determination of flash point - Abel closed‑cup method" specifies the manual and automated Abel closed‑cup test for determining the flash point of combustible liquids. The m…
ISO 15236-2:2017
ДействующийSteel cord conveyor belts — Part 2: Preferred belt types
Overview ISO 15236-2:2017 is an international standard that specifies preferred types of steel cord conveyor belts used as reinforcement in the longitudinal direction. These conveyor belts are design…