ISO 15883-5:2021
Washer-disinfectors — Part 5: Performance requirements and test method criteria for demonstrating cleaning efficacy
Washer-disinfectors — Part 5: Performance requirements and test method criteria for demonstrating cleaning efficacy
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 59
- Дата публикации:
- 30 июля 2021 г.
- Издание:
- ISO IS 15883 edition 1 version 1
- ICS:
- 11.080.10
This document specifies procedures and test methods used to demonstrate the cleaning efficacy of washer-disinfectors (WD) and their accessories intended to be used for cleaning of reusable medical devices. NOTE 1 The requirements can be used for washer-disinfectors intended for use with other articles used in the context of medical, dental, laboratory, pharmaceutical and veterinary practice. NOTE 2 This document does not apply to the activities to be performed by the manufacturers of reusable medical devices.
Abstract
Overview - ISO 15883-5:2021 (Washer‑disinfectors, Cleaning Efficacy)
ISO 15883-5:2021 specifies performance requirements and test‑method criteria to demonstrate the cleaning efficacy of washer‑disinfectors (WD) and their accessories used for cleaning reusable medical devices. The standard defines how to carry out both type testing (simulated use) and performance qualification (clinical use) soiled‑load tests, identifies relevant analytes and test soils, and sets expectations for visual and analytical acceptance. It applies also to WD used in dental, laboratory, pharmaceutical and veterinary contexts, but excludes prion verification and manufacturer internal device‑manufacturing activities.
Key technical topics and requirements
- Scope and terms: Defines key terms (e.g., load, test soil, analyte, alert/action level) and references ISO 15883‑1 and ISO 10993 series for biological evaluation.
- Test soils and load considerations: Guidance for selection and preparation of representative test soils and surrogate products to mimic clinical contamination.
- Cleaning efficacy test criteria: Requirements for visual examination, analytical assays (protein, haemoglobin and other analytes), and criteria for declaring items “clean.”
- Type testing vs performance qualification: Two‑phase approach - simulated type tests with defined test soils and clinical performance qualification with the most challenging clinical soils.
- Test method validation: Requirements for validating soiling methods, detection/sampling methods and analyte assays used for conformity testing.
- Process residuals and risk analysis: Assessment of residual detergents/chemicals, cytotoxicity considerations, sampling methods and acceptance criteria for residuals.
- Alert and action levels: Introduction of alert/action thresholds for analytes to support interpretation of cleaning validation.
- Informative and normative annexes: Includes examples of test soils (Annex A), a validated protein immersion test protocol and performance assessment (Annex B), protein and haemoglobin detection methods (Annex C & D) and sample worksheets (Annex E).
Practical applications - who uses ISO 15883-5
- Washer‑disinfector manufacturers for product design validation and type testing.
- Sterile processing departments (hospital CSSD/central sterilization) for qualification and routine performance verification.
- Independent testing laboratories performing conformity and cleaning validation tests.
- Regulatory and procurement teams assessing WD performance claims.
- Infection prevention and control specialists ensuring validated cleaning processes for reusable devices.
Related standards
- ISO 15883‑1 (General requirements, terms and tests)
- Other parts of the ISO 15883 series (device‑specific performance requirements, e.g., ISO 15883‑7)
- ISO 10993‑1 and ISO 10993‑5 (biological evaluation and cytotoxicity)
ISO 15883‑5 is a practical reference for implementing robust cleaning validation programs for washer‑disinfectors, ensuring reproducible, auditable demonstration of cleaning efficacy for reusable medical devices.
Технические детали
- Технический комитет
- ISO/TC 198 - Sterilization of health care products
- SKU
- ISO 15883-5:2021
Похожие стандарты
Стандарты, упомянутые в описании
BS EN ISO 15883-1:2025
ДействующийWasher-disinfectors. General requirements, terms and definitions and tests.
ISO 10993-12:2012
ОтменёнBiological evaluation of medical devices — Part 12: Sample preparation and reference materials
BS EN ISO 15883-5:2021
ДействующийWasher-disinfectors. Performance requirements and test method criteria for demonstrating cleaning efficacy.
ISO 15883-6:2011
ОтменёнWasher-disinfectors — Part 6: Requirements and tests for washer-disinfectors employing thermal disinfection f…
Overview ISO 15883-6:2011 - Washer-disinfectors - Part 6 specifies particular requirements and tests for washer-disinfectors employing thermal disinfection intended for cleaning and disinfecting non-…
ISO 15883-7:2025
ДействующийWasher-disinfectors — Part 7: Requirements and tests for washer-disinfectors employing chemical disinfection…
Overview ISO 15883-7:2025 specifies requirements and test methods for washer‑disinfectors (WD) that employ chemical disinfection for non‑critical, thermolabile medical devices and health‑care equipme…