ISO 16900-14:2020
Respiratory protective devices — Methods of test and test equipment — Part 14: Measurement of sound pressure level
Respiratory protective devices — Methods of test and test equipment — Part 14: Measurement of sound pressure level
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 11
- Дата публикации:
- 8 мая 2020 г.
- Издание:
- ISO IS 16900 edition 2 version 1
- ICS:
- 13.340.30
This document specifies laboratory test methods for measuring the sound pressure level generated by the respiratory protective device (RPD) and by RPD warning devices, measured on a headform to which the RPD is fitted.
Abstract
Overview
ISO 16900-14:2020 specifies laboratory test methods for measuring the sound pressure level produced by respiratory protective devices (RPDs) and by RPD warning devices. Measurements are made on a standardized headform fitted with special ear inserts and microphones while the RPD is operated under defined breathing-machine or metabolic-simulator conditions. The standard defines two main methods: Method A (noise level of the RPD, excluding warning devices) and Method B (warning sound pressure level).
Key topics and technical requirements
- Test set-up
- Use the ISO RPD headform (medium size) attached to an RPD torso; torso covered with a cotton T‑shirt to avoid reflected noise.
- Microphones mounted in special ear inserts; microphone surface positioned at the flat ear surface ±1 mm.
- The headform is used regardless of the RPD interface size to ensure repeatable acoustical coupling.
- Equipment
- Sound level meter meeting IEC 61672-1 Class 2 (Method A) and a sound spectrum analyser capable of one‑third‑octave bands per IEC 61260-1 (Method B).
- Sound level calibrator meeting IEC 60942 Class 2 and an adaptor for in‑situ calibration.
- Microphones specified as 12 mm diameter pressure or omnidirectional types depending on method.
- Breathing machine or metabolic simulator as per ISO 16900-5.
- Procedures
- Calibrate microphone/system with calibrator before measurement.
- Measure A‑weighted equivalent continuous sound pressure level (Lp,A,eqT) at left and right ears (Method A) or at the ear nearest the warning device (Method B).
- Background noise (with breathing machine running but without RPD) must be measured - maximum 70 dBA.
- Ambient test conditions normally 16 °C to 32 °C and (50 ± 30) % RH.
- Reporting and uncertainty
- Test report must include parameters listed in Clause 4 (number of specimens, conditioning, operating conditions, duration, deviations), background level, maximum measured Lp,A,eqT and an estimate of measurement uncertainty (see Annex A and guidance such as JCGM 100).
Applications and users
- Who uses it:
- RPD manufacturers (design validation and product development)
- Accredited testing laboratories and certification bodies
- PPE safety engineers, acousticians, and regulatory compliance teams
- Practical uses:
- Quantifying wearer noise exposure and comfort
- Verifying audibility and compliance of integrated warning devices
- Supporting performance standards, product labeling, and certification
Related standards
- ISO 16900-5 (RPD headforms, breathing machine)
- ISO 16972 (terms and definitions)
- IEC 61672-1 (sound level meters)
- IEC 61260-1 (fractional‑octave filters)
- IEC 60942 (sound calibrators)
- ISO 2768-2 (geometrical tolerances)
Keywords: ISO 16900-14, respiratory protective devices, sound pressure level, RPD noise measurement, A‑weighted sound level, RPD warning devices, headform testing.
Технические детали
- Технический комитет
- ISO/TC 94/SC 15 - Respiratory protective devices
- SKU
- ISO 16900-14:2020
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61672-1:2013
ДействующийElectroacoustics - Sound level meters - Part 1: Specifications
Overview IEC 61672-1:2013 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the performance requirements for sound level meters used in elec…
IEC 61260-1:2014
ДействующийElectroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications
Overview IEC 61260-1:2014 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies the performance requirements for octave-band and fractional-octa…
IEC 60942:2017
ДействующийElectroacoustics - Sound calibrators
Overview IEC 60942:2017 - Electroacoustics - Sound calibrators defines performance, test and documentation requirements for portable and laboratory sound calibrators used to generate a known sound pr…
ISO 16900-5:2016
ДействующийRespiratory protective devices — Methods of test and test equipment — Part 5: Breathing machine, metabolic si…
Overview ISO 16900-5:2016 - Respiratory protective devices defines standardized test equipment and fixtures used in laboratory testing of respiratory protective devices (RPD). This part of ISO 16900…