ISO 4869-2:2018
Acoustics — Hearing protectors — Part 2: Estimation of effective A-weighted sound pressure levels when hearing protectors are worn
Acoustics — Hearing protectors — Part 2: Estimation of effective A-weighted sound pressure levels when hearing protectors are worn
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 18
- Дата публикации:
- 4 октября 2018 г.
- Издание:
- ISO IS 4869 edition 2 version 1
- ICS:
- 13.340.20
This document specifies three methods (the octave-band, HML and SNR methods) of estimating the A-weighted sound pressure levels effective when hearing protectors are worn. The methods are applicable to either the sound pressure level or the equivalent continuous sound pressure level of the noise. Although primarily intended for steady noise exposures, the methods are also applicable to noises containing impulsive components. It is possible that these methods could not be suitable for use with peak sound pressure level measurements. The octave-band, H, M, L or SNR values are suitable for establishing sound attenuation criteria for selecting or comparing hearing protectors, and/or setting minimum acceptable sound attenuation requirements.
Abstract
Overview
ISO 4869-2:2018 - "Acoustics - Hearing protectors - Part 2" specifies standardized methods to estimate the effective A‑weighted sound pressure level when hearing protectors are worn. It defines three calculation procedures (the octave‑band, HML, and SNR methods) that allow users to convert measured workplace noise levels into an effective exposure level behind a given hearing protector. The methods apply to both instantaneous sound pressure levels and equivalent continuous levels (LAeq), are primarily intended for steady noise but may be used with noises containing impulsive components, and note that they may be unsuitable for peak SPL measurements.
Key topics and technical requirements
- Three estimation methods
- Octave‑band method: uses octave‑band noise levels plus octave‑band attenuation data (from ISO 4869‑1) for a noise‑specific calculation.
- HML method: uses three attenuation values (H, M, L) derived from octave‑band data combined with A‑ and C‑weighted noise levels for simplified estimates.
- SNR method: uses a single number rating (SNR) subtracted from the C‑weighted noise level for a quick estimate.
- Assumed Protection Value (APV): APV for each octave band is calculated from laboratory mean attenuation (m) and standard deviation (s) using APV = m − α·s. Table 1 in the standard provides α constants for protection performance levels (e.g., α = 1.00 for 84 % protection performance).
- Applicability and limits:
- Methods are valid only when protectors are worn and maintained correctly and when ISO 4869‑1 attenuation data represent the target population.
- Uncertainty of attenuation values and ratings is addressed (see Annex E).
- Output metrics: effective A‑weighted sound pressure level (L′p,Ax) and predicted noise level reduction (PNRx).
Applications - who uses it and why
ISO 4869-2 is essential for:
- Acoustical and occupational safety engineers performing noise risk assessments and hearing conservation.
- Hearing protector manufacturers for product rating and comparison.
- Safety managers and compliance officers selecting appropriate PPE and setting attenuation criteria.
- Consultants estimating employee exposure and supporting hearing protection programs.
Typical uses:
- Estimating workplace effective exposure behind earplugs or earmuffs.
- Comparing hearing protectors (SNR, H/M/L, octave‑band criteria).
- Setting minimum acceptable attenuation requirements and informing PPE selection.
Related standards
- ISO 4869‑1 - Subjective method for measurement of sound attenuation (required input data).
- ISO 9612 - Determination of occupational noise exposure (related measurement procedures).
- IEC 61672‑1 - Sound level meter specifications (weighting functions).
Keywords: ISO 4869-2, hearing protection, A-weighted sound pressure level, octave-band method, HML method, SNR, assumed protection value, noise exposure, sound attenuation, hearing protectors selection.
Технические детали
- Технический комитет
- ISO/TC 43/SC 1 - Noise
- SKU
- ISO 4869-2:2018
Похожие стандарты
Стандарты, упомянутые в описании
ISO 4869-1:2018
ДействующийAcoustics — Hearing protectors — Part 1: Subjective method for the measurement of sound attenuation
Overview ISO 4869-1:2018 - "Acoustics - Hearing protectors - Part 1: Subjective method for the measurement of sound attenuation" defines a laboratory, subjective method to measure the sound attenuati…
ISO 9612:2009
ОтменёнAcoustics — Determination of occupational noise exposure — Engineering method
Overview ISO 9612:2009 - "Acoustics - Determination of occupational noise exposure - Engineering method" defines an engineering-grade approach for measuring and calculating workers’ noise exposure le…
IEC 61672-1:2013
ДействующийElectroacoustics - Sound level meters - Part 1: Specifications
Overview IEC 61672-1:2013 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the performance requirements for sound level meters used in elec…