ISO 5832-7:2024
Implants for surgery — Metallic materials — Part 7: Forgeable and cold-formed cobalt-chromium-nickel-molybdenum-iron alloy
Implants for surgery — Metallic materials — Part 7: Forgeable and cold-formed cobalt-chromium-nickel-molybdenum-iron alloy
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 3
- Дата публикации:
- 8 апреля 2024 г.
- Издание:
- ISO IS 5832 edition 4 version 1
- ICS:
- 11.040.40
This document specifies the characteristics of, and corresponding test methods for, forgeable and cold-formed cobalt-chromium-nickel-molybdenum-iron alloy for use in the manufacture of surgical implants. NOTE The mechanical properties of a sample obtained from a finished product made of this alloy can differ from those specified in this document.
Abstract
Overview
ISO 5832-7:2024 is an international standard developed by ISO that specifies requirements for forgeable and cold-formed cobalt-chromium-nickel-molybdenum-iron alloy used in surgical implants. This standard provides manufacturers with detailed characteristics and test methods to ensure consistency, safety, and performance of metallic materials intended for medical implant applications. Ensuring compliance with ISO 5832-7:2024 supports quality assurance and regulatory acceptance across global medical device markets.
Key Topics
-
Material Composition
The standard defines the chemical composition of cobalt-chromium-nickel-molybdenum-iron alloy, specifying strict limits for major elements such as cobalt, chromium, nickel, molybdenum, iron, and restricted impurities. -
Microstructure Requirements
Grain size and inclusion content must meet uniformity and purity specifications to enhance mechanical performance and corrosion resistance in surgical environments.- Grain size: No coarser than designated granularity
- Inclusion types: Limits set for sulfides, aluminates, silicates, and oxides
-
Mechanical Properties
Minimum values for tensile strength, yield strength, and elongation after fracture are specified for various processing conditions (annealed, hot-worked, cold-worked, and spring temper). -
Testing Protocols
Standardized test methods are referenced for chemical analysis, microstructural examination, and mechanical testing to align with recognized international procedures.
Applications
ISO 5832-7:2024 is critical for manufacturers and engineers engaged in the design and production of metallic surgical implants, including:
- Orthopedic implants (hip, knee, and shoulder prostheses)
- Trauma and reconstruction plates
- Spinal fixation devices
- Cardiovascular device components
Using a forgeable and cold-formed cobalt-chromium-nickel-molybdenum-iron alloy ensures:
- High strength and durability for demanding biomechanical environments
- Corrosion resistance crucial for implant longevity in the human body
- Biocompatibility backed by long-term clinical experience
The standard also enables validation of material quality throughout the production lifecycle, supporting both internal quality control and regulatory submissions.
Related Standards
Organizations involved in surgical implant manufacturing often reference ISO 5832-7 alongside other key standards for metallic implant materials and testing:
- ISO 643: Steels - Micrographic determination of apparent grain size
- ISO 4967: Steel - Determination of non-metallic inclusions - Micrographic method using standard diagrams
- ISO 6892-1: Metallic materials - Tensile testing at room temperature
- Other ISO 5832 Series Parts: Covering different alloys and processing methods for medical implants
Complying with ISO 5832-7:2024 and related standards helps ensure international acceptance and competitiveness for medical devices utilizing metallic materials in surgical settings.
Keywords: ISO 5832-7:2024, surgical implants, cobalt-chromium-nickel-molybdenum-iron alloy, metallic materials, implant manufacturing, medical device standards, mechanical properties, biocompatibility, corrosion resistance, microstructure, international standards, orthopedic implants
Технические детали
- Технический комитет
- ISO/TC 150/SC 1 - Materials
- SKU
- ISO 5832-7:2024
Похожие стандарты
Стандарты, упомянутые в описании
ISO 5832-7:2016
ОтменёнImplants for surgery — Metallic materials — Part 7: Forgeable and cold-formed cobalt-chromium-nickel-molybden…
ISO 6431:1992
ОтменёнPneumatic fluid power — Single rod cylinders, 1 000 kPa (10 bar) series, with detachable mountings, bores fro…
ISO 4967:2013
ОтменёнSteel — Determination of content of non-metallic inclusions — Micrographic method using standard diagrams
Overview ISO 4967:2013 - Steel: Determination of content of non‑metallic inclusions - micrographic method using standard diagrams - defines a standardized metallographic procedure to assess non‑metal…
ISO 6892-1:2019
ДействующийMetallic materials — Tensile testing — Part 1: Method of test at room temperature
Overview ISO 6892-1:2019 - "Metallic materials - Tensile testing - Part 1: Method of test at room temperature" specifies a standardized method for performing tensile tests on metallic materials at ro…
ISO 5832-3:2021
ДействующийImplants for surgery — Metallic materials — Part 3: Wrought titanium 6-aluminium 4-vanadium alloy
Overview ISO 5832-3:2021 - "Implants for surgery - Metallic materials - Part 3: Wrought titanium 6‑aluminium 4‑vanadium alloy (Ti‑6Al‑4V)" - specifies the chemical, microstructural and mechanical cha…