ISO 6182-2:2012
Fire protection — Automatic sprinkler systems — Part 2: Requirements and test methods for wet alarm valves, retard chambers and water motor alarms
Fire protection — Automatic sprinkler systems — Part 2: Requirements and test methods for wet alarm valves, retard chambers and water motor alarms
- Статус документа:
- Отменён
- Формат:
- Электронный (PDF)
- Количество страниц:
- 24
- Дата публикации:
- 6 декабря 2012 г.
- Издание:
- ISO IS 6182 edition 3 version 1
- ICS:
- 13.220.20
ISO 6182-2:2012 specifies performance, requirements, methods of test and marking requirements, for wet alarm valves, retard chambers, water motor alarms and manufacturers' specified relevant trim used in wet pipe automatic fire protection systems. ISO 6182-2:2012 is not applicable to performance and test requirements for other auxiliary components or attachments to alarm valves.
Abstract
Overview
ISO 6182-2:2012 specifies performance, requirements, test methods and marking for wet alarm valves, retard chambers and water motor alarms used in wet-pipe automatic sprinkler systems. It covers the components and manufacturers’ specified trim that form part of wet alarm valve assemblies, defining how these parts must perform, be tested and be marked for safe, reliable operation in fire protection systems. The standard does not apply to other auxiliary components or attachments not specified by manufacturers.
Key topics and technical requirements
- Scope and applicability: Applies to wet alarm valves, retard chambers, water motor alarms and relevant trim used in wet-pipe automatic sprinkler systems.
- Nominal sizes: Valve sizes specified (40 mm to 250 mm) and allowance for internal waterway differences.
- Rated working pressure: Minimum rated working pressure is 1.2 MPa (12 bar); marking required if machined for lower pressures.
- Materials and construction:
- Bodies and covers must have corrosion resistance at least equivalent to cast iron.
- Cover fasteners must be steel, stainless steel, titanium or equivalent.
- Restrictions on non-metallic components in bodies/covers and limits on low-melting-point metals.
- Performance and hydraulic criteria:
- Minimum opening/sensitivity, hydraulic friction loss, clearances and allowable leakage are defined.
- Requirements for sealing assemblies (clappers, seat rings) and reinforced elastomeric elements.
- Testing and quality control:
- Defined tests include endurance, hydraulic friction loss, leakage and deformation, body strength, operational performance, spring/diaphragm, sealing elements, warm/air aging for non-metallic parts, retard chamber and water motor alarm tests, salt mist corrosion and production testing.
- Marking and documentation: Marking requirements and manufacturer’s installation instructions are specified to ensure traceability and correct installation.
Applications and who uses this standard
ISO 6182-2:2012 is used for:
- Manufacturers of wet alarm valves, retard chambers and water motor alarms to design, test and mark compliant products.
- Test laboratories performing type and production tests to verify performance and durability.
- Fire protection engineers and specifiers selecting components for wet-pipe sprinkler systems.
- Installers and maintenance teams following manufacturer instructions and compliance checks.
- Authorities having jurisdiction and procurement bodies assessing conformity for building safety and code compliance.
Practical uses include product development, acceptance testing, procurement specifications, system commissioning, and routine maintenance validation.
Related standards
- ISO 6182 series (other parts): Part 1 (sprinklers), Part 3 (dry pipe valves), Part 4 (quick-opening devices), Part 5 (deluge valves), Part 6 (check valves), Part 7 (ESFR sprinklers), Part 8 (pre-action dry alarm valves), Part 9 (water mist nozzles), Part 10 (domestic sprinklers), Part 11 (pipe hangers), Part 12 (grooved-end components).
- Normative references: ISO 898-1 and ISO 898-2 (mechanical properties of fasteners).
Keywords: ISO 6182-2:2012, wet alarm valves, retard chambers, water motor alarms, automatic sprinkler systems, fire protection, test methods, requirements, marking.
Технические детали
- Технический комитет
- ISO/TC 21/SC 5 - Fixed firefighting systems using water