ISO 6182-5:2012
Fire protection — Automatic sprinkler systems — Part 5: Requirements and test methods for deluge valves
Fire protection — Automatic sprinkler systems — Part 5: Requirements and test methods for deluge valves
- Статус документа:
- Отменён
- Формат:
- Электронный (PDF)
- Количество страниц:
- 23
- Дата публикации:
- 6 декабря 2012 г.
- Издание:
- ISO IS 6182 edition 3 version 1
- ICS:
- 13.220.20
ISO 6182-5:2012 specifies performance requirements, methods of test and marking requirements for deluge valves and manufacturer's specified relevant trim used in deluge and pre-action automatic fire protection systems. Deluge valves covered by these requirements can be operated by hydraulic, pneumatic, electric, mechanical, manual, or thermal means, or combinations thereof. Performance and test requirements for other auxiliary components or attachments to deluge valves are not covered by ISO 6182-5:2012. ISO 6182-5:2012 does not cover thermally operated valves released by heat acting directly on the valve. This type of valve utilizes a thermal device, such as the link-and-lever arrangement or glass bulb of a sprinkler, to hold the valve closed. Operation of the thermal device allows the valve to open.
Abstract
Overview
ISO 6182-5:2012 - Fire protection - Automatic sprinkler systems - Part 5: Requirements and test methods for deluge valves - specifies performance criteria, test methods and marking and documentation requirements for deluge valves and manufacturer-specified trim used in deluge and pre-action automatic fire protection systems. The standard covers valves actuated by hydraulic, pneumatic, electric, mechanical, manual or thermal means (or combinations), and defines what is included and explicitly excluded (for example, thermally operated valves released directly by heat and other auxiliary attachments are not covered).
Key topics and technical requirements
ISO 6182-5:2012 addresses the full lifecycle requirements for deluge valves, including:
- Scope and definitions: clear terminology for deluge valves, sealing assemblies, intermediate chambers, leak point, priming water, etc.
- Design and construction requirements: nominal sizes, connections, rated working pressure, body and cover integrity, access for maintenance and corrosion-resistant materials.
- Sealing and component requirements: sealing assembly design, non‑metallic component ageing, reinforced elastomeric elements and clearance tolerances.
- Performance limits and leakage: acceptable leakage limits, minimum opening pressure and hydraulic friction loss requirements.
- Mechanical strength and endurance: body strength, endurance (life-cycle) tests and anti-reseating features.
- Operational and functional tests: operational performance, valve leakage/deformation, hydraulic friction loss and anti-reseating tests.
- Environmental and durability tests: warm-water and air ageing for non‑metallic parts, salt mist corrosion testing.
- Production quality and marking: production testing, manufacturer’s installation instructions and mandatory marking data.
- Normative references: related mechanical fastener standards such as ISO 898-1 and ISO 898-2 are cited.
Practical applications and users
ISO 6182-5:2012 is essential for professionals involved in design, manufacture, testing, installation and approval of deluge and pre-action sprinkler systems:
- Manufacturers use it to design compliant deluge valves, specify materials and produce test protocols.
- Test laboratories and quality control teams apply the specified test methods (leakage, endurance, body strength, hydraulic friction loss, ageing).
- Fire protection engineers and system designers reference the standard when specifying valves for deluge and pre-action systems.
- Installers, commissioning agents and authorities having jurisdiction (AHJs) rely on the marking, installation instructions and test results to accept systems.
- Certification bodies use it as a basis for type approval and product certification.
Related standards
ISO 6182 is a multipart series on automatic sprinkler systems. Relevant parts include:
- ISO 6182-1 (sprinklers), -2 (wet alarm valves), -3 (dry pipe valves), -4 (quick-opening devices), -6 (check valves), -7 (ESFR sprinklers), -8 (pre-action dry alarm valves), -9–12 (nozzles, domestic sprinklers, pipe hangers, grooved-end components).
- Normative mechanical references such as ISO 898-1 and ISO 898-2 (fastener mechanical properties).
Keywords: ISO 6182-5:2012, deluge valves, automatic sprinkler systems, fire protection, test methods, performance requirements, pre-action systems.
Технические детали
- Технический комитет
- ISO/TC 21/SC 5 - Fixed firefighting systems using water
- SKU
- ISO 6182-5:2012
Похожие стандарты
Стандарты, упомянутые в описании
ISO 8981:1993
ОтменёнWheat — Identification of varieties by electrophoresis
ISO 898-2:2012
ОтменёнMechanical properties of fasteners made of carbon steel and alloy steel — Part 2: Nuts with specified propert…
ISO 6182-17:2020
ДействующийFire protection — Automatic sprinkler systems — Part 17: Requirements and test methods for pressure reducing…
Overview ISO 6182-17:2020 defines requirements and test methods for pressure reducing valves used in water-based fire protection and automatic sprinkler systems. The standard covers both pilot-operat…