ISO 7240-17:2020
Fire detection and fire alarm systems — Part 17: Transmission path isolators
Fire detection and fire alarm systems — Part 17: Transmission path isolators
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 30
- Дата публикации:
- 7 февраля 2020 г.
- Издание:
- ISO IS 7240 edition 2 version 1
- ICS:
- 13.220.20
This document specifies the requirements, test methods and performance criteria for transmission path isolators for use in fire detection and fire alarm systems for buildings (for general requirements and definitions, see ISO 7240‑1). Means of isolation or protection incorporated within control and indicating equipment are not covered by this document.
Abstract
Overview
ISO 7240-17:2020 is an international standard developed by ISO that addresses transmission path isolators used within fire detection and fire alarm systems for buildings. This standard is a critical part of the broader ISO 7240 series dedicated to ensuring the robustness and reliability of fire alarm systems. Specifically, ISO 7240-17:2020 details the requirements, test methods, and performance criteria that transmission path isolators must meet to perform effectively in real-world environments.
Transmission path isolators play a key role in limiting the negative impact of faults, such as short circuits, in the wiring of fire alarm systems. By isolating issues and maintaining loop integrity, these devices help keep the overall alarm system operational even if a section of the transmission path becomes compromised.
Key Topics
- Scope and Purpose: Covers requirements for isolators used in transmission paths of fire alarm system loops, excluding those integrated into control and indicating equipment.
- Product Definitions: Clarifies critical terms such as transmission path isolator, closed condition, open condition, field device, and non-field device.
- Design and Adjustment:
- Isolators must operate as specified in the manufacturer’s documentation.
- Protection against unauthorized adjustments and requirements for both manufacturer and on-site settings.
- Software-controlled isolators must ensure data integrity with non-volatile memory and secure programming.
- Status Indication: If provided, status indicators must avoid red, which is typically reserved for fire alarm signals.
- Test Requirements: Rigorous test methods covering:
- Functionality under normal and fault conditions
- Environmental resilience (heat, cold, humidity, corrosion, vibration, shock)
- Electromagnetic compatibility (EMC) and immunity
- Installation Guidance: Manufacturers are required to provide comprehensive technical data for system designers to ensure correct selection and integration.
- Compliance and Reporting: Transmission path isolators must be tested for reproducibility and report performance data in line with the prescribed test schedule.
Applications
Transmission path isolators, as standardized by ISO 7240-17:2020, are essential for:
- Commercial and Public Buildings: Ensuring continued protection in offices, hospitals, schools, and other occupancies where fire alarm system reliability is paramount.
- Complex Fire Alarm Loops: Protecting multi-device circuits by segmenting the wiring into manageable sections, so faults in one segment don't disable the entire system.
- Retrofitting and Upgrading: Providing compatibility and enhanced resilience in both new installations and upgrades of older fire detection systems.
- Meeting Regulatory Requirements: Helping building owners, system designers, and installers comply with international safety regulations and facilitate approvals from authorities.
Related Standards
ISO 7240-17:2020 works alongside several other key standards in the fire detection and alarm field, including:
- ISO 7240-1: Fire detection and alarm systems - General requirements and definitions
- IEC 60068 series: Environmental testing for electronic components, including considerations for heat, cold, vibration, shock, and corrosion
- IEC 62599-2: Alarm systems - Electromagnetic compatibility and immunity requirements
- Other parts of ISO 7240 series: Covering components like smoke detectors, heat detectors, and control equipment
By adhering to ISO 7240-17:2020, manufacturers, specifiers, and installers ensure that transmission path isolators enhance the resilience and reliability of fire alarm systems, minimizing risks associated with wiring faults and supporting the safety of building occupants.
Технические детали
- Технический комитет
- ISO/TC 21/SC 3 - Fire detection and alarm systems
- SKU
- ISO 7240-17:2020
Похожие стандарты
Стандарты, упомянутые в описании
ISO 7240-32:2025
ДействующийFire detection and alarm systems — Part 32: Non-resettable line-type heat detectors
Overview ISO 7240-32:2025 is part of the ISO 7240 series dedicated to fire detection and alarm systems. This specific standard focuses on non-resettable line-type heat detectors (NLTHD), which are he…
ISO 7240-13:2005
ОтменёнFire detection and alarm systems — Part 13: Compatibility assessment of system components
IEC 60068-2-21:2021
ДействующийEnvironmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices
Overview IEC 60068-2-21:2021 is an International Electrotechnical Commission (IEC) standard focused on environmental testing, specifically Test U, which assesses the robustness of terminations and in…
IEC 62599-2:2010
ДействующийAlarm systems - Part 2: Electromagnetic compatibility - Immunity requirements for components of fire and secu…
Overview IEC 62599-2:2010 is an international standard published by the International Electrotechnical Commission (IEC) that specifies electromagnetic compatibility (EMC) immunity requirements for th…