ISO 8536-5:2004
Infusion equipment for medical use — Part 5: Burette infusion sets for single use, gravity feed
Infusion equipment for medical use — Part 5: Burette infusion sets for single use, gravity feed
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 5
- Дата публикации:
- 19 января 2004 г.
- Издание:
- ISO IS 8536 edition 2 version 1
- ICS:
- 11.040.20
ISO 8536-5:2004 specifies requirements for types of single-use, gravity feed burette infusion sets of 50 ml, 100 ml and 150 ml nominal capacity for medical use in order to ensure compatibility of use with containers for infusion solutions and intravenous equipment. ISO 8536-5:2004 also provides guidance on specifications relating to the quality and performance of materials. In some countries, national pharmacopoeia or other national regulations are legally binding and take precedence over ISO 8536-5:2004.
Abstract
Overview - ISO 8536-5:2004 (Burette infusion sets, gravity feed)
ISO 8536-5:2004 defines requirements for single‑use, gravity feed burette infusion sets with nominal capacities of 50 ml, 100 ml and 150 ml. The standard ensures compatibility of these burette sets with infusion solution containers and other intravenous equipment, and gives guidance on material quality and performance. It is part of the ISO 8536 series on infusion equipment for medical use. Note: national pharmacopoeia or regulations may take precedence over this ISO standard.
Key topics and technical requirements
- Scope and designation
- Applies to single‑use gravity feed burette sets (designation example: Burette set ISO 8536-5 - BS - 100 - G).
- Design and construction
- Burette must be made of rigid or semi‑rigid transparent plastics to permit observation of fluid.
- Must allow filling from a main container and be closed off to serve as a self‑vented reservoir.
- Filtered air‑venting capability is required above the top graduation mark; a separate air‑inlet device (if used) must comply with ISO 8536-4.
- Protective caps must be provided to maintain sterility of internal parts until use.
- Graduation and volume
- Nominal volume is designated by total graduated capacity (50/100/150 ml).
- The standard specifies scale intervals, legibility, durability and placement of graduation lines and numbered marks, plus tolerance and zero‑position considerations to compensate for outlet and valve displacement.
- Materials, chemical and biological safety
- Materials in contact with solutions must meet quality and performance guidance in Clauses 6–8; chemical and biological requirements reference ISO 8536-4.
- Labelling and packaging
- Labelling, sterility and packaging requirements are aligned with ISO 8536-4.
Practical applications and users
- Manufacturers and product designers use ISO 8536-5 to design and validate burette infusion sets that are compatible with standard IV systems and meet international performance criteria.
- Quality assurance and regulatory teams rely on the standard for conformity assessment, material selection, labelling and packaging controls.
- Procurement and clinical engineering use the standard to specify compliant single‑use burette sets for hospitals, clinics and other healthcare facilities.
- Standards bodies and test laboratories refer to ISO 8536-5 when testing physical, chemical and biological properties of infusion equipment.
Related standards
- ISO 8536-4 - Infusion sets for single use, gravity feed (closely referenced throughout ISO 8536-5)
- Other parts of the ISO 8536 series cover bottles, closures, pressure infusion equipment and accessories (see ISO 8536 Parts 1–11 for the full series).
Keywords: ISO 8536-5:2004, burette infusion sets, gravity feed, single-use infusion equipment, infusion set standards, medical device compatibility, graduated burette.
Технические детали
- Технический комитет
- ISO/TC 76 - Transfusion, infusion and injection, and blood processing equipment for medical and pharmaceutical use
- SKU
- ISO 8536-5:2004
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 8536-15:2022
ДействующийInfusion equipment for medical use — Part 15: Light-protective infusion sets for single use
Overview ISO 8536-15:2022 - Infusion equipment for medical use - Part 15: Light-protective infusion sets for single use specifies performance, material, testing and labelling requirements for single‑…
ISO 8536-4:2019
ДействующийInfusion equipment for medical use — Part 4: Infusion sets for single use, gravity feed
Overview - ISO 8536-4:2019 (Infusion sets for single use, gravity feed) ISO 8536-4:2019 is the sixth-edition international standard that specifies requirements for single-use, gravity-feed infusion s…
ISO 8212:1986
ОтменёнSoaps and detergents — Techniques of sampling during manufacture
Overview Standard Reference: ISO 8212:1986 Title: Soaps and detergents - Techniques of sampling during manufacture ISO 8212:1986 defines standardized techniques for taking representative samples of s…
ISO 20662:2020
ДействующийShips and marine technology — Hopper dredger supervisory and control systems
Overview ISO 20662:2020 - Ships and marine technology: Hopper dredger supervisory and control systems (HD‑SCS) - specifies the components, structure, general requirements, and functional requirements…
ISO 3021:2023
ДействующийAdventure tourism — Hiking and trekking activities — Requirements and recommendations
Overview ISO 3021:2023 - Adventure tourism: Hiking and trekking activities - Requirements and recommendations defines safety-focused requirements and recommendations for hiking and trekking offered a…
ISO 3826-2:2008
ДействующийPlastics collapsible containers for human blood and blood components — Part 2: Graphical symbols for use on l…
Overview ISO 3826-2:2008 - "Plastics collapsible containers for human blood and blood components - Part 2: Graphical symbols for use on labels and instruction leaflets" defines a system of internatio…
ISO/IEC 24730-1:2014
ДействующийInformation technology — Real-time locating systems (RTLS) — Part 1: Application programming interface (API)
Overview ISO/IEC 24730-1:2014 specifies the Application Programming Interface (API) for Real‑Time Locating Systems (RTLS). The standard defines a minimal, interoperable boundary that lets application…
ISO 8668-5:1992
ДействующийAircraft — Terminal junction systems — Part 5: Detail specification for type 3 system
Overview - ISO 8668-5:1992 (Aircraft terminal junction systems, Type 3) ISO 8668-5:1992 defines the detail specification for Type 3 Terminal Junction Systems (TJS) used in aircraft electrical install…