ISO 9236-1:2004
Photography — Sensitometry of screen/film systems for medical radiography — Part 1: Determination of sensitometric curve shape, speed and average gradient
Photography — Sensitometry of screen/film systems for medical radiography — Part 1: Determination of sensitometric curve shape, speed and average gradient
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 25
- Дата публикации:
- 27 января 2004 г.
- Издание:
- ISO IS 9236 edition 2 version 1
- ICS:
- 37.040.25
ISO 9236-1:2004 specifies methods for the determination of the sensitometric curve shape, average gradient and speed of a single sample of a screen/film/filmholder/processing system for medical radiography. It is not applicable to special radiographic applications such as mammography, dental radiography and direct-exposing medical radiographic systems (see for example ISO 5799). The filmholder can be any means that ensures close screen/film contact and prevents the film from being exposed to ambient light. In particular, the filmholder can be a light-tight vacuum bag, as often used in the laboratory, or a radiographic cassette as used in medical radiography.
Abstract
Overview
ISO 9236-1:2004 - Photography - Sensitometry of screen/film systems for medical radiography - Part 1 - defines standardized methods to determine the sensitometric curve shape, speed, and average gradient of a single screen/film/filmholder/processing system used in medical radiography. The standard excludes special modalities such as mammography, dental radiography and direct-exposing systems. It covers laboratory and clinical-like test conditions, measurement uncertainties, and reporting.
Key topics and technical requirements
- Sensitometric curve shape: Measured under low-scatter conditions using intensity-scale X‑ray sensitometry (preferably an inverse‑square sensitometer). The curve (density vs log exposure) is the basis for other metrics.
- Average gradient: Defined as the slope joining two specified points on the sensitometric curve - a measure of effective contrast.
- Speed: Quantitative response of the screen/film system for specified exposure, processing and measurement conditions. Speed is measured under simulated clinical exposures (with phantoms) and requires absolute air‑kerma measurement in gray (Gy).
- Beam and equipment: Use high‑frequency (multipulse) or at least 12‑pulse high‑voltage generators; tungsten or tungsten‑based targets; permanent filtration equivalent to 2.5 mm ± 0.2 mm Al.
- Dosimetry: Calibrated detectors required. Air‑kerma uncertainty: <3% for collimated (no scatter) beams and <5% when scatter is included. The standard recommends a spherical ionization chamber of 30 cm to 100 cm volume for measurements involving scattered radiation.
- Geometry and phantoms: Four defined measurement techniques simulate typical clinical situations (extremities, skull, lumbar spine and colon, and chest) to capture energy and scatter dependence of speed.
- Environmental & processing controls: Film/storage at 23 °C ± 2 °C, relative humidity equilibrium at 50 ± 20%; films handled in total darkness; processing per film‑manufacturer recommendations (processing is part of the tested system).
- Uncertainty & reporting: Guidance on combined/expanded uncertainty and required test report contents is included.
Applications and who uses this standard
- Quality assurance and acceptance testing of screen/film systems in radiology departments.
- Medical physicists conducting performance characterization and dose‑efficiency assessments.
- Film and screen manufacturers validating product performance (speed, contrast).
- Independent test laboratories and regulatory bodies establishing baseline performance metrics.
- Radiography QA teams using standardized data to optimize imaging protocols and processing.
Related standards
- ISO 9236-3 (mammography-specific sensitometry)
- ISO 5799 (direct-exposing medical radiographic systems)
- ISO 5-2, ISO 5-3 (density measurement)
- ISO 554 (conditioning atmospheres)
- IEC 60522 (permanent filtration of X‑ray tube assemblies)
Keywords: ISO 9236-1:2004, sensitometry, screen/film systems, medical radiography, sensitometric curve, speed, average gradient, air kerma, dosimetry, radiographic phantoms, radiology quality assurance.
Технические детали
- Технический комитет
- ISO/TC 42 - Photography
- SKU
- ISO 9236-1:2004
Похожие стандарты
Стандарты, упомянутые в описании
ISO 9236-3:1999
ДействующийPhotography — Sensitometry of screen/film systems for medical radiography — Part 3: Determination of sensitom…
Overview ISO 9236-3:1999 specifies standardized methods for determining the sensitometric curve shape, speed, and average gradient of screen/film/filmholder/processing systems in mammography. Develop…
ISO 5799:1991
ДействующийPhotography — Direct-exposing medical and dental radiographic film/process systems — Determination of ISO spe…
Overview ISO 5799:1991 - Photography: Direct-exposing medical and dental radiographic film/process systems - specifies standardized methods to determine ISO Speed and ISO average gradient for film/pr…
ISO 5249:1988
ДействующийTextile machinery and accessories — Guide rollers for dyeing and finishing machinery — Main dimensions
Overview ISO 5249:1988 establishes standardized main dimensions and performance requirements for steel guide rollers used in dyeing and finishing machinery within the textile industry. This internati…
ISO 532:1975
ОтменёнAcoustics — Method for calculating loudness level
ISO 5548:2004
ДействующийCaseins and caseinates — Determination of lactose content — Photometric method
Overview ISO 5548:2004 (IDF 106:2004) defines a photometric method for determining the content of lactose and other soluble carbohydrates in caseins and caseinates. The method is intended for product…