ISO 9705-1:2016
Reaction to fire tests — Room corner test for wall and ceiling lining products — Part 1: Test method for a small room configuration
Reaction to fire tests — Room corner test for wall and ceiling lining products — Part 1: Test method for a small room configuration
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 48
- Дата публикации:
- 18 февраля 2016 г.
- Издание:
- ISO IS 9705 edition 1 version 1
- ICS:
- 13.220.50
ISO 9705-1:2016 specifies the test method to evaluate the reaction of wall and ceiling products to fire when installed at the surface of a small room and exposed directly to a specified ignition source. The test represents a fire scenario, which starts under well-ventilated conditions in a corner of a specified room with a single open doorway. Tests performed in accordance with the method specified in this part of ISO 9705 provide data for the early stages of a fire from ignition up to flashover. The method does not evaluate the fire resistance of products. The method is not intended to evaluate floor coverings. This method is not suitable for sandwich panel building systems, pipe insulation and façades for which specific ISO standards (i.e. ISO 13784, ISO 20632 and ISO 13785, respectively) are available.
Abstract
Overview
ISO 9705-1:2016 - Reaction to fire tests - Room corner test for wall and ceiling lining products - Part 1: Test method for a small room configuration specifies a full-scale laboratory method to evaluate the reaction to fire of wall and ceiling lining products installed on the surfaces of a small room. The test reproduces a well-ventilated corner ignition scenario with a single open doorway and records fire development from ignition through the early growth stage up to flashover. The method is focused on reaction-to-fire behavior (not fire resistance) and is not intended for floor coverings or for specific systems covered by other ISO standards.
Key topics and technical requirements
The standard establishes the complete test setup, instrumentation and procedures required for reliable, repeatable room corner tests:
- Test room and specimen configuration: defined small-room dimensions, doorway arrangement, substrate and mounting requirements for wall and ceiling lining products.
- Ignition source: specified burner type, location and heat output to produce a representative corner ignition.
- Hood and exhaust system: design and performance requirements for smoke capture and ducting to measure combustion products.
- Instrumentation and measurements: guidance for volume flow, gas analysis (O2, CO2), optical smoke density (photometers/laser), and exhaust sampling lines.
- System performance and calibration: procedures for system response checks, daily checks, methanol calibration and precision verification.
- Test conduct and reporting: initial conditions, automated data recording, photographic and observational requirements, termination criteria, and test report content.
- Limitations and safety: clear warnings about toxic combustion products and high-temperature hazards; method does not assess fire resistance.
(These topics are consistent with the standard’s clauses on principle, instrumentation, testing procedure and annexes for calibration, calculations and precision.)
Practical applications - who uses ISO 9705-1:2016
- Product manufacturers of wall and ceiling linings to demonstrate reaction-to-fire performance for product development and marketing.
- Independent fire testing laboratories performing standardized full-scale room corner tests.
- Fire safety engineers and consultants assessing early fire growth, ignition behavior and potential for flashover in small-room scenarios.
- Regulators, specifiers and building code authorities referencing standardized reaction-to-fire data for material selection, classification and compliance.
- Architects and contractors seeking objective performance data for interior finishes.
Related standards
- ISO 9705-2 (Technical background and guidance)
- Standards for specific systems (method not suitable for): ISO 13784 (pipe insulation), ISO 20632 (sandwich panel systems), ISO 13785 (façades)
- Complementary reaction-to-fire and smoke measurement standards referenced within ISO 9705-1.
Keywords: ISO 9705-1:2016, room corner test, reaction to fire, small room configuration, wall and ceiling lining products, full-scale fire test, flashover, fire testing methodology.
Технические детали
- Технический комитет
- ISO/TC 92/SC 1 - Fire initiation and growth
- SKU
- ISO 9705-1:2016
Похожие стандарты
Стандарты, упомянутые в описании
ISO 13784-2:2020
ДействующийReaction-to-fire tests for sandwich panel building systems — Part 2: Test method for large rooms
Overview ISO 13784-2:2020 - Reaction-to-fire tests for sandwich panel building systems, Part 2 - specifies a large‑room scale test method for assessing the reaction‑to‑fire behaviour of thermal insul…
ISO 2063-2:2017
ДействующийThermal spraying — Zinc, aluminium and their alloys — Part 2: Execution of corrosion protection systems
Overview ISO 2063-2:2017 defines requirements for the execution of corrosion protection systems applied by thermal spraying of zinc, aluminium and their alloys. It covers surface preparation, thermal…
ISO 13785-1:2002
ДействующийReaction-to-fire tests for façades — Part 1: Intermediate-scale test
Overview ISO 13785-1:2002 - Reaction-to-fire tests for façades (Intermediate-scale test) specifies a screening test method to assess the reaction-to-fire behaviour of façade and cladding materials wh…