ISO 9892:1992
Uranium metal, uranium dioxide powder and pellets, and uranyl nitrate solutions — Determination of fluorine content — Fluoride ion selective electrode method
Uranium metal, uranium dioxide powder and pellets, and uranyl nitrate solutions — Determination of fluorine content — Fluoride ion selective electrode method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 5
- Дата публикации:
- 25 марта 1992 г.
- Издание:
- ISO IS 9892 edition 1 version 1
- ICS:
- 27.120.30
Specifies an analytical method which can be used within the concentration range of 1 µg to 0,001 g of fluorine per gram of the sample. Specifies the principle, the reagents, the apparatus, the sampling, the procedure, the expression of results and the test report.
Abstract
Overview
ISO 9892:1992 defines an analytical standard method for determining the fluorine content in uranium metal, uranium dioxide powder and pellets, and uranyl nitrate solutions. Utilizing the fluoride ion selective electrode method, this standard covers procedures suitable for detecting fluorine concentrations ranging from 1 µg to 0.001 g per gram of sample. It specifies requirements for reagents, apparatus, sampling, measurement procedures, result expression, and reporting. This method is essential for ensuring quality control and safety in nuclear fuel technology by accurately quantifying fluorine, which can impact nuclear material properties.
Key Topics
-
Scope and applicability
Covers determination of fluorine in uranium metal, uranium dioxide powder/pellets, and uranyl nitrate solutions. Impurities such as boron, silicon, aluminum, and iron are tolerated up to specified levels. However, zirconium presence interferes with analysis and must be avoided. -
Analytical principle
The method relies on a fluoride ion selective electrode (ISE) responding to the logarithmic fluoride ion concentration following the Nernst equation. A standard addition procedure is employed, where a known fluoride standard is added to the sample solution to improve accuracy. -
Sample preparation
Uranium metal and uranyl nitrate solutions require minimal preparation. Uranium dioxide powder is finely ground to ensure homogeneity and dissolution. Pellets are crushed before analysis. Samples are dissolved in nitric acid pretreated with fluoride in closed polyethylene containers to prevent loss. -
Apparatus and reagents
Key equipment includes:- Fluoride ion selective electrode resistant to 2 mol/L nitric acid
- Reference electrode
- Digital millivoltmeter with high input impedance and 0.1 mV sensitivity
- Polyethylene bottles and polypropylene beakers
Analytical grade reagents and properly prepared fluoride standard solutions ensure reliable measurements.
-
Measurement procedure
Measurement includes:- Dissolving the sample with nitric acid
- Measuring initial potential E1 with the fluoride electrode
- Adding incremental volumes of fluoride standard solution
- Measuring changed potentials E2, E3, etc.
- Calculating fluorine content using equations derived from the Nernst equation with standard addition corrections.
-
Quality control and reproducibility
Multiple measurements confirm result consistency, with reproducibility expressed as twice the standard deviation. Specific reproducibility data is provided for uranium dioxide powder and pellets. -
Special considerations
The method addresses interference by strong fluoride complexants and provides alternate procedures and blank testing for samples with complex matrices.
Applications
ISO 9892:1992 is critical for nuclear fuel quality assurance and chemical analysis in nuclear energy sectors, including:
- Monitoring fluorine content in nuclear fuel materials to avoid detrimental effects on fuel performance and safety.
- Environmental and process control in uranium processing facilities.
- Analytical laboratories performing routine testing of nuclear materials to ensure compliance with purity specifications.
- Research and development activities involving uranium compounds where precise fluorine quantification is necessary.
Related Standards
- ISO/TC 85, Nuclear Energy Committee standards for nuclear fuel technology.
- Standards on uranium compound characterization and analytical chemistry.
- Electrode and ion-selective measurement standards developed jointly with the International Electrotechnical Commission (IEC).
- Other ISO standards related to nuclear materials testing, handling of radioactive materials, and chemical assay procedures.
By applying the fluoride ion selective electrode method as described in ISO 9892:1992, laboratories can achieve precise, reliable, and reproducible determination of fluorine in critical uranium materials, supporting safe and efficient nuclear energy operations.
Технические детали
- Технический комитет
- ISO/TC 85/SC 5 - Nuclear installations, processes and technologies
- SKU
- ISO 9892:1992
Похожие стандарты
Другие стандарты ISO
ISO 8212:1986
ОтменёнSoaps and detergents — Techniques of sampling during manufacture
Overview Standard Reference: ISO 8212:1986 Title: Soaps and detergents - Techniques of sampling during manufacture ISO 8212:1986 defines standardized techniques for taking representative samples of s…
ISO 20662:2020
ДействующийShips and marine technology — Hopper dredger supervisory and control systems
Overview ISO 20662:2020 - Ships and marine technology: Hopper dredger supervisory and control systems (HD‑SCS) - specifies the components, structure, general requirements, and functional requirements…
ISO 3021:2023
ДействующийAdventure tourism — Hiking and trekking activities — Requirements and recommendations
Overview ISO 3021:2023 - Adventure tourism: Hiking and trekking activities - Requirements and recommendations defines safety-focused requirements and recommendations for hiking and trekking offered a…
ISO 3826-2:2008
ДействующийPlastics collapsible containers for human blood and blood components — Part 2: Graphical symbols for use on l…
Overview ISO 3826-2:2008 - "Plastics collapsible containers for human blood and blood components - Part 2: Graphical symbols for use on labels and instruction leaflets" defines a system of internatio…
ISO/IEC 24730-1:2014
ДействующийInformation technology — Real-time locating systems (RTLS) — Part 1: Application programming interface (API)
Overview ISO/IEC 24730-1:2014 specifies the Application Programming Interface (API) for Real‑Time Locating Systems (RTLS). The standard defines a minimal, interoperable boundary that lets application…
ISO 8668-5:1992
ДействующийAircraft — Terminal junction systems — Part 5: Detail specification for type 3 system
Overview - ISO 8668-5:1992 (Aircraft terminal junction systems, Type 3) ISO 8668-5:1992 defines the detail specification for Type 3 Terminal Junction Systems (TJS) used in aircraft electrical install…
ISO 7574-3:1985
ДействующийAcoustics — Statistical methods for determining and verifying stated noise emission values of machinery and e…
Overview ISO 7574-3:1985 is part of the ISO 7574 series on acoustics and provides a simple (transition) statistical method for determining and verifying stated noise emission values for batches (lots…
ISO 15638-15:2014
ДействующийIntelligent transport systems — Framework for cooperative telematics applications for regulated vehicles (TAR…
Overview - ISO 15638-15:2014 (Vehicle location monitoring, TARV) ISO 15638-15:2014 is part of the ISO 15638 suite for Intelligent Transport Systems (ITS) and defines the framework and data specificat…