ASTM D56-22
Standard Test Method for Flash Point by Tag Closed Cup Tester
Standard Test Method for Flash Point by Tag Closed Cup Tester
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 13
- Дата публикации:
- 1 июля 2022 г.
- Издание:
- D56
- ICS:
- 75.080
SIGNIFICANCE AND USE 5.1 Flash point measures the tendency of the specimen to form a flammable mixture with air under controlled laboratory conditions. It is only one of a number of properties that shall be considered in assessing the overall flammability hazard of a material. 5.2 Flash point is used in shipping and safety regulations to define flammable and combustible materials. One should consult the particular regulation involved for precise definitions of these classes. 5.3 Flash point can indicate the possible presence of highly volatile and flammable materials in a relatively nonvolatile or nonflammable material. For example, an abnormally low flash point on a sample of kerosene can indicate gasoline contamination. SCOPE 1.1 This test method covers the determination of the flash point, by Tag manual and automated closed testers, of liquids with a viscosity below 5.5 mm2/s (cSt) at 40 °C (104 °F), or below 9.5 mm2/s (cSt) at 25 °C (77 °F), and a flash point below 93 °C (200 °F). 1.1.1 Two sets of test conditions are used within this test method: low temperature (LT) test conditions for expected flash points ≥ 60 °C. 1.1.2 For the closed-cup flash point of liquids with the following properties: a viscosity of 5.5 mm2/s (cSt) or more at 40 °C (104 °F); a viscosity of 9.5 mm2/s (cSt) or more at 25 °C (77 °F); a flash point of 93 °C (200 °F) or higher; a tendency to form a surface film under test conditions; or containing suspended solids, Test Method D93 can be used. 1.1.3 For cut-back asphalts refer to Test Methods D1310 and D3143. Note 1: The U.S. Department of Transportation (RSTA)2 and U.S. Department of Labor (OSHA) have established that liquids with a flash point under 37.8 °C (100 °F) are flammable as determined by this test method for those liquids that have a viscosity less than 5.5 mm2/s (cSt) at 40 °C (104 °F) or 9.5 mm2/s (cSt) or less at 25 °C (77 °F), or do not contain suspended solids or do not have a tendency to form a surface film while under test. Other flash point classifications have been established by these departments for liquids using this test method. 1.2 This test method can be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and cannot be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions. However, results of this test method can be used as elements of fire risk assessment that takes into account all of the factors that are pertinent to an assessment of the fire hazard of a particular end use. 1.3 Related standards are Test Methods D93, D1310, D3828, D3278, and D3941. 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.5 WARNING—Mercury has been designated by many regulatory agencies as a hazardous substance that can cause serious medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Use Caution when handling mercury and mercury-containing products. See the applicable product Safety Data Sheet (SDS) for additional information. The potential exists that selling mercury or mercury-containing products, or both, is prohibited by local or national law. Users must determine legality of sales in their location. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements see 6.5, 7.1, 9.3, 11.1.4, and refer to Safety Data Sheets. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Pr...
Abstract
Overview
ASTM D56-22, Standard Test Method for Flash Point by Tag Closed Cup Tester, is a widely recognized method for determining the flash point of volatile liquids under controlled laboratory conditions. Developed by ASTM International, this standard specifically covers liquids with viscosities below 5.5 mm²/s at 40°C (104°F), or below 9.5 mm²/s at 25°C (77°F), and with flash points below 93°C (200°F). The Tag Closed Cup Tester can be used in both manual and automated formats. This method is crucial for industries handling flammable and combustible liquids, playing a critical role in regulatory compliance, shipping, and safety management.
Key Topics
- Flash Point Determination: The core of ASTM D56-22 is the evaluation of a liquid’s flash point, defined as the lowest temperature at which an ignition source causes vapors above the sample to ignite.
- Applicability: The standard is suitable for liquids with specific viscosity and flash point ranges. For liquids outside these ranges, alternative methods such as ASTM D93 may be recommended.
- Test Conditions: The method defines low temperature (LT) and high temperature (HT) test conditions depending on the expected flash point.
- Use in Regulations: Flash point data obtained by this method are used to classify materials as flammable or combustible in accordance with shipping and safety regulations (e.g., by OSHA and U.S. Department of Transportation).
- Sample Handling and Apparatus: The method details the proper preparation, handling, and equipment (Tag Closed Cup Tester, temperature measuring devices, ignition sources) to ensure accurate, reproducible results.
- Limitations: This method provides data under laboratory conditions and should not be used as the sole measure of fire hazard or risk in real-world scenarios.
Applications
ASTM D56-22 is extensively used in industries requiring precise control over the storage, transport, and handling of flammable and combustible liquids. Key applications include:
- Quality Control: Ensures uniformity in product batches by verifying that flash points meet required specifications.
- Regulatory Compliance: Supports classification of liquids for transportation and workplace safety according to international and national regulations. This is vital for compliance with OSHA and U.S. DOT rules.
- Contamination Detection: Atypical flash point values can indicate contamination (e.g., presence of volatile solvents like gasoline in kerosene), which assists in quality investigations and troubleshooting.
- Fire Risk Assessment: While not a measure of actual fire risk under operational conditions, flash point data is a foundational element in broader risk assessments and fire safety documentation.
- Product Specification: Used in technical data sheets, safety data sheets (SDS), and material certifications for downstream users in chemicals, fuels, paints, and lubricants industries.
Related Standards
ASTM D56-22 is part of a suite of ASTM standards for flash point determination. Relevant related standards include:
- ASTM D93: Flash Point by Pensky-Martens Closed Cup Tester - for liquids with higher viscosity or flash points above 93°C (200°F).
- ASTM D1310 and D3143: Methods for flash point testing of cut-back asphalts using open-cup techniques.
- ASTM D3278 and D3828: Small scale closed-cup methods for flash point determination.
- ASTM D3941: Equilibrium Method for Flash Point - provides a predictive alternative for certain substances.
- ISO 17034 and ISO Guide 35: International guidance for reference material producers and characterization, enhancing quality assurance practices in flash point testing.
By adhering to ASTM D56-22, laboratories and manufacturers ensure they are following globally recognized protocols for accurate determination of flash points in low-viscosity liquids, contributing to safer handling, storage, and transport of hazardous materials.
Технические детали
- Технический комитет
- D02 - Petroleum Products, Liquid Fuels, and Lubricants
- SKU
- ASTM D56-22
Похожие стандарты
Другие стандарты ASTM
ASTM E7-22
ДействующийStandard Terminology Relating to Metallography
Overview ASTM E7-22 - Standard Terminology Relating to Metallography is a key terminology standard developed by ASTM Committee E04. It establishes uniform definitions for terms, acronyms, and symbols…
ASTM E18-22
ДействующийStandard Test Methods for Rockwell Hardness of Metallic Materials
Overview ASTM E18-22: Standard Test Methods for Rockwell Hardness of Metallic Materials defines procedures and requirements for determining the Rockwell and Rockwell superficial hardness of metallic…
ASTM E29-22
ДействующийStandard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications
Overview ASTM E29-22: Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications provides essential guidelines for the use of significant digits when est…
ASTM E11-22
ДействующийStandard Specification for Woven Wire Test Sieve Cloth and Test Sieves
Overview ASTM E11-22: Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves establishes the technical requirements for woven wire sieve cloth and the construction of test sieves used…
ASTM ISO/ASTM51607-22
ДействующийStandard Practice for Use of an Alanine-EPR Dosimetry System
Overview ASTM ISO/ASTM51607-22 provides internationally recognized guidance on the implementation and use of the alanine-EPR dosimetry system to measure absorbed dose during radiation processing. Thi…
ASTM ISO/ASTM51401-21
ДействующийStandard Practice for Use of a Dichromate Dosimetry System
Overview ASTM ISO/ASTM51401-21: Standard Practice for Use of a Dichromate Dosimetry System establishes best practices for the preparation, testing, and operation of dichromate dosimeters to measure t…
ASTM ISO/ASTM51650-21
ДействующийStandard Practice for Use of a Cellulose Triacetate Dosimetry System
Overview ASTM ISO/ASTM 51650-21: Standard Practice for Use of a Cellulose Triacetate Dosimetry System establishes procedures for employing cellulose triacetate (CTA) dosimetry systems to measure abso…
ASTM ISO/ASTM51275-21
ДействующийStandard Practice for Use of a Radiochromic Film Dosimetry System
Overview ASTM ISO/ASTM51275-21 is an international standard practice developed by ASTM for the use of radiochromic film dosimetry systems. This document provides protocols and recommendations for emp…