ASTM ISO/ASTM51607-22
Standard Practice for Use of an Alanine-EPR Dosimetry System
Standard Practice for Use of an Alanine-EPR Dosimetry System
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 7
- Дата публикации:
- 1 января 2022 г.
- Издание:
- ISO/ASTM51607
- ICS:
- 17.240
SIGNIFICANCE AND USE 4.1 The alanine-EPR dosimetry system provides a means for measuring absorbed dose. It is based on the measurement of specific stable free radicals in crystalline alanine generated by ionizing radiation. 4.2 Alanine-EPR dosimetry systems are used in reference- or transfer-standard or routine dosimetry systems in radiation applications that include: sterilization of medical devices and pharmaceuticals, food irradiation, polymer modifications, medical therapy and radiation damage studies in materials (1, 13-15). SCOPE 1.1 This practice covers dosimeter materials, instrumentation, and procedures for using the alanine-EPR dosimetry system to measure the absorbed dose in the photon or electron radiation processing of materials. The alanine system is based on electron paramagnetic resonance (EPR) spectroscopy of free radicals derived from the amino acid alanine.2 1.2 The alanine dosimeter is classified as a type I dosimeter as it is affected by individual influence quantities in a well-defined way that can be expressed in terms of independent correction factors (see ISO/ASTM Practice 52628). The alanine dosimeter may be used in either a reference standard dosimetry system or in a routine dosimetry system. 1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM 52628 “Practice for Dosimetry in Radiation Processing” for alanine dosimetry system. It should be read in conjunction with ISO/ASTM 52628. 1.4 This practice covers the use of alanine-EPR dosimetry systems under the following conditions: 1.4.1 The absorbed dose range is between 0.001 kGy and 150 kGy. 1.4.2 The absorbed dose rate is up to 1 × 102 Gy s-1 for continuous radiation fields and up to 3 × 1010 Gy s-1 for pulsed radiation fields (1-4).3 1.4.3 The radiation energy for photons and electrons is between 0.1 MeV and 30 MeV (1, 2, 5-8). 1.4.4 The irradiation temperature is between –78 °C and +70 °C (2, 9-12). 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Abstract
Overview
ASTM ISO/ASTM51607-22 provides internationally recognized guidance on the implementation and use of the alanine-EPR dosimetry system to measure absorbed dose during radiation processing. This standard practice, developed jointly by ASTM and ISO, outlines the materials, instrumentation, and procedures needed to apply electron paramagnetic resonance (EPR) measurement for accurate and reliable dose assessment. Alanine-EPR dosimetry is utilized in a wide range of industrial and medical applications due to its efficiency in detecting stable free radicals formed in crystalline alanine after exposure to ionizing radiation.
The document details system components, necessary environmental controls, calibration and verification protocols, and documentation requirements-ensuring the dosimetry process complies with international best practices and regulatory requirements.
Key Topics
- Alanine-EPR Dosimetry System: Establishes the use of crystalline alanine dosimeters, EPR spectrometers, dosimeter holders, and reference standards to quantify absorbed dose in materials exposed to photon or electron irradiation.
- Dosimeter Classification: Describes alanine dosimeters as Type I, meaning their response to influencing quantities is consistent, allowing for well-defined correction factors.
- Influence Quantities: Identifies critical factors such as temperature, humidity, dose rate, and irradiation energy that can affect dosimeter response, and recommends controls or corrections to maintain measurement accuracy.
- Calibration and Verification: Emphasizes the importance of routine calibration and verification using check standards and EPR reference materials to ensure consistent and traceable dose measurements.
- Expanded Uncertainty: Provides typical uncertainty estimates for measurements, with reference-standard systems achieving 2–4% and routine systems 4–6%, both at a 95% confidence level.
Applications
The alanine-EPR dosimetry system, as defined by this standard, is widely used in:
- Sterilization of Medical Devices and Pharmaceuticals: Ensures proper dosing of ionizing radiation to achieve sterilization without compromising material integrity.
- Food Irradiation: Facilitates safe and effective disinfection, preservation, and processing of food products.
- Polymer Modification: Supports quality control in processes that rely on specific radiation-induced changes in polymers.
- Medical Therapy: Provides precise dose measurements in treatments such as radiotherapy, contributing to patient safety and treatment efficacy.
- Radiation Damage Studies: Used for materials science research to evaluate the effects of ionizing radiation on different substances.
The system demonstrates its versatility and reliability within photon and electron energies of 0.1 MeV to 30 MeV, dose rates up to 1 x 10² Gy/s for continuous and up to 3 x 10¹⁰ Gy/s for pulsed fields, and irradiation temperatures ranging from –78 °C to +70 °C.
Related Standards
Implementation of this standard should consider conjunction with the following documents and practices to ensure comprehensive radiation processing dosimetry:
- ISO/ASTM 52628: Practice for Dosimetry in Radiation Processing (compliance for dosimetry systems).
- ISO/ASTM 51261: Calibration of Routine Dosimetry Systems for Radiation Processing.
- ISO/ASTM 51707: Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing.
- ISO/ASTM 52701: Performance Characterization of Dosimeters and Dosimetry Systems.
- ASTM E170/E3083: Terminology Relating to Radiation Measurements and Dosimetry.
- ICRU Reports 80 & 85a: Fundamental quantities and dosimetry systems in radiation processing.
By referencing ASTM ISO/ASTM51607-22 alongside these related standards, organizations can achieve robust quality assurance, compliance with international trade and safety requirements, and ensure reliable, repeatable results in radiation dose measurement using the alanine-EPR dosimetry system.
Технические детали
- Технический комитет
- E61 - Radiation Processing
- SKU
- ASTM ISO/ASTM51607-22
Похожие стандарты
Другие стандарты ASTM
ASTM E7-22
ДействующийStandard Terminology Relating to Metallography
Overview ASTM E7-22 - Standard Terminology Relating to Metallography is a key terminology standard developed by ASTM Committee E04. It establishes uniform definitions for terms, acronyms, and symbols…
ASTM D56-22
ДействующийStandard Test Method for Flash Point by Tag Closed Cup Tester
Overview ASTM D56-22, Standard Test Method for Flash Point by Tag Closed Cup Tester, is a widely recognized method for determining the flash point of volatile liquids under controlled laboratory cond…
ASTM E18-22
ДействующийStandard Test Methods for Rockwell Hardness of Metallic Materials
Overview ASTM E18-22: Standard Test Methods for Rockwell Hardness of Metallic Materials defines procedures and requirements for determining the Rockwell and Rockwell superficial hardness of metallic…
ASTM E29-22
ДействующийStandard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications
Overview ASTM E29-22: Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications provides essential guidelines for the use of significant digits when est…
ASTM E11-22
ДействующийStandard Specification for Woven Wire Test Sieve Cloth and Test Sieves
Overview ASTM E11-22: Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves establishes the technical requirements for woven wire sieve cloth and the construction of test sieves used…
ASTM ISO/ASTM51401-21
ДействующийStandard Practice for Use of a Dichromate Dosimetry System
Overview ASTM ISO/ASTM51401-21: Standard Practice for Use of a Dichromate Dosimetry System establishes best practices for the preparation, testing, and operation of dichromate dosimeters to measure t…
ASTM ISO/ASTM51650-21
ДействующийStandard Practice for Use of a Cellulose Triacetate Dosimetry System
Overview ASTM ISO/ASTM 51650-21: Standard Practice for Use of a Cellulose Triacetate Dosimetry System establishes procedures for employing cellulose triacetate (CTA) dosimetry systems to measure abso…
ASTM ISO/ASTM51275-21
ДействующийStandard Practice for Use of a Radiochromic Film Dosimetry System
Overview ASTM ISO/ASTM51275-21 is an international standard practice developed by ASTM for the use of radiochromic film dosimetry systems. This document provides protocols and recommendations for emp…