IEC 62642-5-3:2010
Alarm systems - Intrusion and hold-up systems - Part 5-3: Interconnections - Requirements for equipment using radio frequency techniques
Alarm systems - Intrusion and hold-up systems - Part 5-3: Interconnections - Requirements for equipment using radio frequency techniques
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 60
- Дата публикации:
- 7 октября 2010 г.
- Издание:
- IEC IS 62642 edition 1 version 1
- ICS:
- 13.320
IEC 62642-5-3:2010 applies to intrusion alarm equipment using radio frequency links and located on protected premises. This standard defines the terms used in the field of intrusion alarm equipment using radio frequency links as well as the requirements relevant to the equipment. It is used in conjunction with the other parts of the IEC 62642 series that define the functional requirements of the equipment regardless of the type of interconnections used.
Abstract
Overview
IEC 62642-5-3:2010 is an essential international standard developed by the International Electrotechnical Commission (IEC) focusing on alarm systems with radio frequency (RF) interconnections. Specifically, it addresses intrusion and hold-up alarm systems that use RF links on protected premises. This standard specifies the terminology, requirements, and testing methods for alarm equipment employing radio frequency techniques to ensure reliable and secure communication between components.
Part of the comprehensive IEC 62642 series, IEC 62642-5-3 complements other parts covering system requirements, detectors, control equipment, warning devices, power supplies, and application guidelines. Its targeted emphasis on RF interconnections makes it pivotal for modern wireless intrusion detection and security systems.
Key Topics
-
Scope of Application The standard applies exclusively to RF links within intrusion alarm equipment located on protected premises-not including long-range radio transmissions.
-
Terminology and Definitions IEC 62642-5-3 carefully defines terms related to RF alarm equipment, facilitating a common understanding for manufacturers, integrators, and users.
-
Performance Requirements Elaborates on general requirements for RF communication including:
- Immunity to signal attenuation and interference
- Resistance to message collisions and substitution (both unintentional and intentional)
- Frequency band integrity and interference management for different equipment grades
- Ensuring continuous RF link monitoring and failure detection
-
Testing Procedures Details normative test methods to verify the immunity and robustness of RF equipment against various disturbances, including:
- RF disturbance tests for attenuation, collision immunity, throughput, message substitution, and interference
- Antenna testing criteria for specific equipment grades
- Environmental testing to assess equipment durability under real-world conditions
-
Security and Reliability Emphasizes resilience against intentional attacks such as interference and message substitution to maintain system integrity and secure premises.
Applications
IEC 62642-5-3:2010 is critical for manufacturers designing wireless intrusion and hold-up alarm systems ensuring compliance with international best practices for RF communication. Typical applications include:
- Wireless alarm system components such as sensors, detectors, transmitters, and control panels communicating over RF links
- Security solutions in residential, commercial, and industrial premises requiring high levels of intrusion detection reliability without extensive wired installations
- Integration into comprehensive electronic security systems where maintaining signal integrity and preventing unauthorized interference is mandatory
- Designers and installers referencing the standard to select compliant equipment and verify installation quality for optimum alarm system interconnection performance
Related Standards
IEC 62642-5-3 is part of the broader IEC 62642 series that addresses various components of intrusion and hold-up alarm systems:
- IEC 62642-1: System requirements for alarm systems
- IEC 62642-2-2 to 2-73: Various standardized intrusion detectors (e.g., passive infrared, microwave, magnetic contacts, glass break detectors)
- IEC 62642-3: Control and indicating equipment specifications
- IEC 62642-4: Warning devices for alarm systems
- IEC 62642-6: Power supply requirements
- IEC 62642-7: Application guidelines
- IEC 62642-8: Security fog devices and systems
Compliance with IEC 62642-5-3 ensures seamless interoperability with other IEC 62642 standard elements, fostering robust and secure alarm systems using RF technologies.
Keywords: IEC 62642-5-3, alarm systems, intrusion alarm, hold-up systems, radio frequency, RF interconnections, wireless alarm equipment, security standards, intrusion detection, IEC standards, RF immunity, alarm system testing, electronic security standards, RF interference, alarm equipment requirements.
Технические детали
- Технический комитет
- TC 79 - Alarm and electronic security systems
- SKU
- IEC 62642-5-3:2010
Похожие стандарты
Стандарты, упомянутые в описании
IEC 62642-8:2011
ДействующийAlarm systems - Intrusion and hold-up systems - Part 8: Security fog device/systems
Overview IEC 62642-8:2011 is an international standard developed by the International Electrotechnical Commission (IEC) that defines the specifications for security fog devices and systems used withi…
IEC 62642-1:2010
ДействующийAlarm systems - Intrusion and hold-up systems - Part 1: System requirements
Overview IEC 62642-1:2010 - “Alarm systems - Intrusion and hold‑up systems - Part 1: System requirements” defines the system‑level requirements for intrusion and hold‑up alarm systems (I&HAS) install…
IEC 62642-2-2:2010
ДействующийAlarm systems - Intrusion and hold-up systems - Part 2-2: Intrusion detectors - Passive infrared detectors
Overview - IEC 62642-2-2:2010 (SIST IEC 62642-2-2:2024) IEC 62642-2-2 specifies requirements and test methods for passive infrared (PIR) intrusion detectors used in alarm systems installed in buildin…
IEC 62642-3:2010
ДействующийAlarm systems - Intrusion and hold-up systems - Part 3: Control and indicating equipment
Overview IEC 62642-3:2010 sets the international standard for control and indicating equipment (CIE) used in intrusion and hold-up alarm systems (I&HAS) installed in buildings. Published by the Inter…
IEC 62642-4:2010
ДействующийAlarm systems - Intrusion and hold-up systems - Part 4: Warning devices
Overview IEC 62642-4:2010 is an international standard published by the International Electrotechnical Commission (IEC) that specifies requirements for warning devices used in intrusion and hold-up a…
IEC 62642-6:2011
ДействующийAlarm systems - Intrusion and hold-up systems - Part 6: Power supplies
Overview IEC 62642-6:2011 - adopted as SIST IEC 62642-6:2024 - specifies requirements, performance criteria and test procedures for power supplies used in Intrusion and Hold‑up Alarm Systems (I&HAS).…