EN ISO 8987:2005 PDF
Plastics - Phenolic resins - Determination of reactivity on a B-transformation test plate (ISO 8987:2005)
Plastics - Phenolic resins - Determination of reactivity on a B-transformation test plate (ISO 8987:2005)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 9
- Дата публикации:
- 1 октября 2005 г.
- Издание:
- CEN EN 8987 edition 2 version 1
- ICS:
- 83.080.10
ISO 8987:2005 specifies methods for the determination of the B-transformation time of phenolic resins at a specified temperature and under specified conditions on a heated test plate. Two methods are described, each with a different test plate: Method A -- plate with depressions in the form of segments of spheres; Method B -- flat plate without depressions.
Abstract
Overview
EN ISO 8987:2005 is an international standard established by CEN and ISO for evaluating the reactivity of phenolic resins, a type of thermosetting plastic widely used in various industrial applications. This standard outlines precise methods to determine the B-transformation time of phenolic resins by using heated test plates under controlled temperature conditions. The B-transformation time is a critical parameter indicating the curing stage when the resin transitions from a liquid to a gelled state.
The standard improves quality control in phenolic resin production by providing repeatable and reproducible testing procedures, ensuring consistency and reliability in resin performance.
Key Topics
-
Scope and Purpose EN ISO 8987:2005 specifies test methods for determining the curing time of phenolic resins at specified temperatures using either of two test plate types.
-
Test Methods
- Method A: Utilizes a test plate with depressions shaped as spherical segments. Resin is placed into these depressions and stirred regularly to observe the transition to B-stage.
- Method B: Employs a flat, chromium-plated test plate without depressions. The resin is spread uniformly and stroked with a spatula until it reaches the B-stage.
-
Test Equipment Requirements
- Thermostatic control with precise temperature regulation (±0.5°C).
- Test plates-either segmental depression type or flat, both optionally with integral heaters.
- Timing devices capable of measuring seconds.
- Tools such as glass rods, spatulas, syringes, and balances for handling resin samples.
-
Testing Procedure and Endpoint Detection For both methods, the test starts when resin contacts the plate and ends at the B-transformation point, identified by a change in resin consistency-thread breakage in Method A or gelation in Method B.
-
Reporting and Precision Test reports must include sample identification, method used, test temperature, B-transformation time(s), and test date. The standard states repeatability within ±4% and reproducibility within ±10%, ensuring reliable comparisons of resin reactivity.
Applications
EN ISO 8987:2005 is critical in industries where phenolic resins are used, including:
- Adhesive and composite manufacturing: Monitoring curing times supports product quality and process optimization.
- Electrical and automotive components: Ensures resin consistency for insulating and structural materials.
- Surface coatings and laminates: Guarantees controlled curing stages for durability and performance.
- Material development and research: Enables comparative analysis of resin formulations and catalysts under standardized conditions.
By applying this standard, manufacturers achieve consistent curing behavior, reducing waste and improving material properties critical for end-use reliability.
Related Standards
Professionals working with phenolic resins often refer to complementary standards such as:
- ISO 4644: Covers general methods for testing phenol-formaldehyde resins.
- ISO 1784: Pertains to determination of resin viscosity and flow properties.
- EN ISO 4589: Specifies methods for flame retardancy relevant in phenolic resin applications.
- ISO/TC 61 series: A broad set of standards for plastics testing, including thermosetting materials.
Integrating EN ISO 8987 with these standards ensures comprehensive evaluation and quality control of phenolic resin materials in industrial processes.
By adhering to EN ISO 8987:2005, manufacturers and researchers can reliably determine the B-transformation time of phenolic resins, enabling optimal processing and performance of phenolic-based plastics across a wide range of applications.
Технические детали
- Технический комитет
- CEN/TC 249 - Plastics
- SKU
- EN ISO 8987:2005
Похожие стандарты
Стандарты, упомянутые в описании
ISO 8987:2005
ДействующийPlastics — Phenolic resins — Determination of reactivity on a B-transformation test plate
Overview ISO 8987:2005 - "Plastics - Phenolic resins - Determination of reactivity on a B‑transformation test plate" specifies laboratory test methods to measure the B‑transformation time (reactivity…
BS ISO 17841:2015
ДействующийFine ceramics (advanced ceramics, advanced technical ceramics). Test method for thermal fatigue of fine ceram…
SIST EN ISO 4589-2:2017
ДействующийPlastics - Determination of burning behaviour by oxygen index - Part 2: Ambient-temperature test (ISO 4589-2:…
Overview EN ISO 4589-2:2017 - "Plastics - Determination of burning behaviour by oxygen index - Part 2: Ambient-temperature test" - specifies laboratory methods to determine the oxygen index (OI): the…
SIST EN ISO 8987:2006
ДействующийPlastics - Phenolic resins - Determination of reactivity on a B-transformation test plate (ISO 8987:2005)
Overview SIST EN ISO 8987:2006 is an international standard established by CEN and ISO for evaluating the reactivity of phenolic resins, a type of thermosetting plastic widely used in various industr…