ISO 16000-10:2006 PDF
Indoor air — Part 10: Determination of the emission of volatile organic compounds from building products and furnishing — Emission test cell method
Indoor air — Part 10: Determination of the emission of volatile organic compounds from building products and furnishing — Emission test cell method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 17
- Дата публикации:
- 30 января 2006 г.
- Издание:
- ISO IS 16000 edition 1 version 1
- ICS:
- 13.040.20
ISO 16000-10:2006 specifies a general laboratory test method for determination of the area specific emission rate of volatile organic compounds (VOCs) from newly produced building products or furnishing under defined climate conditions. The method can also, in principle, be applied to aged products. The emission data obtained can be used to calculate concentrations in a model room. According to the definition of an emission test cell, it is also possible to perform non-destructive emission measurements on building products on-site in buildings. However, the procedure for such measurements is not described in ISO 16000-10:2006. An example of an emission test cell is described. ISO 16000-10:2006 is also applicable to wood-based panels and other building products, in order to determine the emission rate of formaldehyde.
Abstract
Overview
ISO 16000-10:2006 - "Indoor air - Part 10: Determination of the emission of volatile organic compounds (VOCs) from building products and furnishing - Emission test cell method" defines a laboratory test method for measuring the area specific emission rate of VOCs emitted from building materials and furnishings. The standard is intended for newly produced (and, in principle, aged) products and produces emission data that can be used to model indoor concentrations in a room. An example emission test cell is provided (Annex C), and quality assurance/quality control requirements are included (Annex A).
Key topics and technical requirements
- Emission test cell concept: A small chamber placed on the surface of the test specimen so the specimen surface forms part of the cell. This enables surface-specific emission measurements (including potential on-site, non-destructive measurement; procedure not specified in this part).
- Controlled test conditions: Tests are conducted at constant temperature, relative humidity and area specific air flow rate. The cell must be supplied with clean, humidified air and the air flow controlled to an accuracy of ±5%.
- Materials and construction: Cell and sampling parts contacting VOCs are normally made from polished stainless steel or glass; sealing materials must be low-emitting and low-adsorbing to avoid background contamination.
- Measured outputs and units: The main result is the area specific emission rate (qA), typically expressed in micrograms per square metre per hour (µg·m−2·h−1). Emission test cell concentrations are measured at the outlet and converted to emission rates using the area specific air flow rate.
- Definitions and metrics: Includes terminology such as air change rate, product loading factor, TVOC (total volatile organic compounds), recovery, and target VOCs.
- Quality & reporting: Annex A covers QA/QC; Clause 14 describes performance characteristics; Clause 15 prescribes test report content.
Practical applications and users
- Provides standardized emission data for:
- Product manufacturers assessing VOC emissions during product development and certification.
- Indoor air quality consultants and environmental engineers modeling occupant exposures and estimating room concentrations.
- Regulators and certification schemes setting emission criteria for building materials and furnishings.
- Laboratories performing emission testing for building products, coatings, adhesives and furnishings.
- Applicable to a broad set of materials including wood-based panels and for formaldehyde emission assessment (measurement procedures for formaldehyde are referenced in ISO 16000-3).
Related standards
- ISO 16000 series (indoor air): especially ISO 16000-6 (VOC analysis), ISO 16000-11 (sampling, storage, specimen preparation), and ISO 16000-3 (formaldehyde).
- EN 717-1 and ISO 12460-1 referenced for formaldehyde from wood-based panels.
Keywords: ISO 16000-10:2006, indoor air, VOC emissions, emission test cell, area specific emission rate, building products, formaldehyde, emission testing, TVOC, air flow control.
Технические детали
- Технический комитет
- ISO/TC 146/SC 6 - Indoor air
- SKU
- ISO 16000-10:2006
Похожие стандарты
Стандарты, упомянутые в описании
BS ISO 16000-36:2018
ДействующийIndoor air. Standard method for assessing the reduction rate of culturable airborne bacteria by air purifiers…
BS ISO 16000-22:2025
ДействующийIndoor air. Detection and quantification of fungal biomass by fungal beta-N-acetylhexosaminidase enzyme activ…
SIST ISO 16000-6:2023
ДействующийIndoor air - Part 6: Determination of organic compounds (VVOC, VOC, SVOC) in indoor and test chamber air by a…
Overview SIST ISO 16000-6:2023 is an international standard developed by the International Organization for Standardization (ISO) that specifies a robust method for the determination of organic compo…
SIST EN ISO 16000-11:2024
ДействующийIndoor air - Part 11: Determination of the emission of volatile organic compounds from samples of building pr…
Overview EN ISO 16000-11:2024 - "Indoor air - Part 11" defines standardized procedures for sampling, transporting, storing and preparing test specimens of building products and furnishings for the de…
ISO 12460-1:2007/Amd 1:2023
ДействующийWood-based panels — Determination of formaldehyde release — Part 1: Formaldehyde emission by the 1-cubic-metr…
Overview ISO 12460-1:2007/Amd 1:2023 is an international amendment to the ISO standard for wood-based panels, specifically addressing the determination of formaldehyde release using the 1-cubic-metre…