ISO 7056:1981 PDF
Plastics laboratory ware — Beakers
Plastics laboratory ware — Beakers
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 8
- Дата публикации:
- 1 сентября 1981 г.
- Издание:
- ISO IS 7056 edition 1 version 1
- ICS:
- 17.060
The requirements specify a series of plastic cylinders having a tapered ore non-tapered form. The capacity is in the range from 25 ml to 5000 ml. For non-opaque beakers the graduation is specified. The construction, dimensions and material are described. The annexes deal with the test for ionic material extracted by water and with the flexibility test.
Abstract
Overview
ISO 7056:1981 - "Plastics laboratory ware - Beakers" specifies construction, dimensions, markings and test methods for squat-form plastic beakers used in laboratories. It applies to beakers with nominal capacities from 25 ml to 5000 ml, in tapered or non‑tapered form. The standard defines graduation rules, material and geometric requirements, and two verification tests provided as annexes (ionic extraction by water at 60 °C and a flexibility test).
Key topics and technical requirements
- Capacities and sizes: Nominal capacities covered: 25, 50, 100, 250, 500, 1000, 2000, 5000 ml with specified figured graduation intervals (e.g., 5 ml intervals for 25 ml beakers, 1000 ml for 5000 ml beakers).
- Graduation and tolerances: Non‑opaque beakers must be graduated externally. Errors in graduation shall not exceed +10% of indicated values. The highest graduation line indicates nominal capacity; the lowest is 20% of nominal.
- Capacity (brimful): Brimful capacity shall be at least 1.3× nominal capacity for sizes up to 500 ml, and 1.2× for larger sizes.
- Material and construction: Beakers must be made of generally non‑brittle plastics, free from moulding defects and stresses; wall thickness must be uniform and base thickness not less than wall thickness. Internal radius at the base junction must be ≥ 3 mm.
- Brim, spout and shape: Brim diameter ≥ 10% greater than average external body diameter; spout orientation and shape requirements ensure pouring without running down the side. Overall height to maximum body diameter ratio between 1.0 and 1.4.
- Markings/inscriptions: Durable markings required: “approximate volumes” (or abbreviation), maker/vendor identification, material name or symbol (e.g., “PP”), manufacturer’s recommended safe maximum temperature, and a pictogram indicating unsuitable for flame or high heat.
- Annex A - Ionic extraction test: Fill with de‑ionized water and hold at 60 ± 2 °C for 3 h. The aqueous extract must be free of suspended matter and the conductivity increase must not exceed specified values (see standard’s Table 2).
- Annex B - Flexibility test: A test pin applies 30 N force; the brim outside diameter must not decrease by more than 10% under test conditions.
Applications and users
ISO 7056 is used to:
- Guide manufacturers of plastic laboratoryware (design, molding, marking).
- Support procurement and specification writers who require compliant plastic beakers.
- Inform laboratory managers, quality assurance, and regulatory teams verifying product conformity.
- Assist test laboratories performing conductivity/extraction and mechanical flexibility checks.
Keywords: ISO 7056, plastics laboratory ware, plastic beakers, graduation tolerance, brimful capacity, ionic extraction test, flexibility test, laboratory glassware standards.
Related standards
- ISO/TC 48 (technical committee responsible for laboratory glassware and related apparatus)
- IEC Publication 335‑1 (safety requirements referenced for test pin)
- ISO 1043 (plastics symbols referenced for material marking)
Технические детали
- Технический комитет
- ISO/TC 48 - Laboratory equipment
- SKU
- ISO 7056:1981
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
SIST ISO 7056:1995
ДействующийPlastics laboratory ware -- Beakers
Overview ISO 7056:1981 - "Plastics laboratory ware - Beakers" specifies construction, dimensions, markings and test methods for squat-form plastic beakers used in laboratories. It applies to beakers…
BS EN ISO 1043-3:2016
ДействующийPlastics. Symbols and abbreviated terms. Plasticizers.
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…