SIST ISO 7056:1995 PDF
Plastics laboratory ware -- Beakers
Plastics laboratory ware -- Beakers
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 8
- Дата публикации:
- 1 августа 1995 г.
- ICS:
- 17.060
- Технический комитет:
- I12 - Imaginarni 12 Imaginarni TC za ISO področje - vzdrževani privzeti ISO standardi
The requirements specify a series of plastic cylinders having a tapered ore non-tapered form. The capacity is in the range from 25 ml to 5000 ml. For non-opaque beakers the graduation is specified. The construction, dimensions and material are described. The annexes deal with the test for ionic material extracted by water and with the flexibility test.
Abstract
Overview
ISO 7056:1981 - "Plastics laboratory ware - Beakers" specifies construction, dimensions, markings and test methods for squat-form plastic beakers used in laboratories. It applies to beakers with nominal capacities from 25 ml to 5000 ml, in tapered or non‑tapered form. The standard defines graduation rules, material and geometric requirements, and two verification tests provided as annexes (ionic extraction by water at 60 °C and a flexibility test).
Key topics and technical requirements
- Capacities and sizes: Nominal capacities covered: 25, 50, 100, 250, 500, 1000, 2000, 5000 ml with specified figured graduation intervals (e.g., 5 ml intervals for 25 ml beakers, 1000 ml for 5000 ml beakers).
- Graduation and tolerances: Non‑opaque beakers must be graduated externally. Errors in graduation shall not exceed +10% of indicated values. The highest graduation line indicates nominal capacity; the lowest is 20% of nominal.
- Capacity (brimful): Brimful capacity shall be at least 1.3× nominal capacity for sizes up to 500 ml, and 1.2× for larger sizes.
- Material and construction: Beakers must be made of generally non‑brittle plastics, free from moulding defects and stresses; wall thickness must be uniform and base thickness not less than wall thickness. Internal radius at the base junction must be ≥ 3 mm.
- Brim, spout and shape: Brim diameter ≥ 10% greater than average external body diameter; spout orientation and shape requirements ensure pouring without running down the side. Overall height to maximum body diameter ratio between 1.0 and 1.4.
- Markings/inscriptions: Durable markings required: “approximate volumes” (or abbreviation), maker/vendor identification, material name or symbol (e.g., “PP”), manufacturer’s recommended safe maximum temperature, and a pictogram indicating unsuitable for flame or high heat.
- Annex A - Ionic extraction test: Fill with de‑ionized water and hold at 60 ± 2 °C for 3 h. The aqueous extract must be free of suspended matter and the conductivity increase must not exceed specified values (see standard’s Table 2).
- Annex B - Flexibility test: A test pin applies 30 N force; the brim outside diameter must not decrease by more than 10% under test conditions.
Applications and users
ISO 7056 is used to:
- Guide manufacturers of plastic laboratoryware (design, molding, marking).
- Support procurement and specification writers who require compliant plastic beakers.
- Inform laboratory managers, quality assurance, and regulatory teams verifying product conformity.
- Assist test laboratories performing conductivity/extraction and mechanical flexibility checks.
Keywords: ISO 7056, plastics laboratory ware, plastic beakers, graduation tolerance, brimful capacity, ionic extraction test, flexibility test, laboratory glassware standards.
Related standards
- ISO/TC 48 (technical committee responsible for laboratory glassware and related apparatus)
- IEC Publication 335‑1 (safety requirements referenced for test pin)
- ISO 1043 (plastics symbols referenced for material marking)
Технические детали
- SKU
- SIST ISO 7056:1995
Похожие стандарты
Упомянутые в описании и другие стандарты SIST
ISO 7056:1981
ДействующийPlastics laboratory ware — Beakers
Overview ISO 7056:1981 - "Plastics laboratory ware - Beakers" specifies construction, dimensions, markings and test methods for squat-form plastic beakers used in laboratories. It applies to beakers…
BS EN ISO 1043-3:2016
ДействующийPlastics. Symbols and abbreviated terms. Plasticizers.
SIST EN ISO 6338:2026
ДействующийMethod to calculate GHG emissions at LNG plant (ISO 6338:2023)
Overview SIST EN ISO 6338:2026 / ISO 6338:2023 establishes a standardized method for calculating greenhouse gas (GHG) emissions at liquefied natural gas (LNG) plants, both onshore and offshore. Devel…
SIST-TP CEN ISO/ASTM TR 52958:2026
Additive manufacturing of metals - Powder bed fusion (PBF) - In-situ coaxial photodiode monitoring for lack o…
Overview SIST-TP CEN ISO/ASTM TR 52958:2026 specifies a workflow for the detection of lack of fusion flaws during the additive manufacturing of metals using powder bed fusion-laser based (PBF-LB) pro…
SIST EN ISO 41002:2026
ДействующийFacility management - Development of the facility management organization (ISO 41002:2026)
Overview SIST EN ISO 41002:2026 - Facility management - Development of the facility management organization offers strategic guidance for building and developing robust facility management (FM) organ…
SIST EN ISO 844:2026
ДействующийRigid cellular plastics - Determination of compressive properties (ISO 844:2026)
Overview SIST EN ISO 844:2026 - Rigid Cellular Plastics: Determination of Compressive Properties (ISO 844:2026) provides standardized methods for measuring the compressive properties of rigid cellula…
SIST-TS CEN ISO/TS 17664-3:2026
ДействующийProcessing of health care products - Information to be provided by the medical device manufacturer for the pr…
Overview SIST-TS CEN ISO/TS 17664-3:2026 sets out comprehensive guidance for grouping reusable medical devices based on their cleaning requirements. This technical specification, prepared collaborati…
SIST EN ISO 8980-4:2026
ДействующийOphthalmic optics - Uncut finished spectacle lenses - Part 4: Specifications and test methods for the propert…
Overview SIST EN ISO 8980-4:2026 specifies requirements and test methods for the properties of anti-reflective coatings and hydrophobic coatings applied to uncut finished spectacle lenses. Developed…