ISO 7884-8:1987 PDF
Glass — Viscosity and viscometric fixed points — Part 8: Determination of (dilatometric) transformation temperature
Glass — Viscosity and viscometric fixed points — Part 8: Determination of (dilatometric) transformation temperature
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 4
- Дата публикации:
- 26 ноября 1987 г.
- Издание:
- ISO IS 7884 edition 1 version 1
- ICS:
- 81.040.01
The temperature characterizes a certain glass transition range from the elastic brittle (low temperature) state to the viscous (high temperature) state of glass. It is used for specifying cooling programmes. The transformation temperature is determined by measuring the change in length, related to the length at intial temperature, of a rod made from the glass under test with temperature. The relative change in length is plotted against the temperature (dilatometer curve). From this dilatometer curve the transformation temperature is determined by a graphic procedure as shown in a diagramm.
Abstract
Overview
ISO 7884-8:1987 - "Glass - Viscosity and viscometric fixed points - Part 8: Determination of (dilatometric) transformation temperature" specifies a dilatometric thermal-expansion method to determine the transformation temperature (tg) of bulk glass. The transformation temperature characterizes the glass transition range between the elastic/brittle (low-temperature) state and the viscous (high-temperature) state and is used for specifying cooling programmes and estimating useful temperature limits for glassware.
Key topics and technical requirements
- Measurement principle: record the relative change in length of a glass rod versus temperature (dilatometer curve) and determine tg graphically by the intersection of two tangents (low‑temperature branch and high‑temperature branch at the inflection point).
- Specimen: rod shape, cross-section about 10–25 mm², and length at least 5×10^4 times the extensometer resolution to avoid measurement artefacts. Cross-section chosen so dilatometer contact stress < 0.1 N/mm².
- Annealing: pre-anneal specimen ~30 °C above estimated tg, then cool to ~150 °C below tg at (2 ± 0.2) °C/min in draught-free air.
- Heating protocol: heat from 200 °C at (5 ± 1) °C/min, recording temperature and length change. Correct for specimen-to-thermocouple temperature differences if needed.
- Apparatus constraints: contact force ≤ 1 N (via spherical-faced contacts), furnace temperature uniformity so deviations along specimen < 5 °C, and furnace capacity up to ~50 °C above expected tg.
- Evaluation and repeatability: perform two runs; if tg values differ ≤ 5 °C, take the mean (round to nearest °C). If difference > 5 °C, repeat on a new sample. Reported precision: repeatability ≈ 3 °C, reproducibility ≈ 6 °C.
- Reporting: include sample description, sampling/preparation, apparatus, corrections applied, number of specimens, tg (°C), and any observed glass changes.
Applications and users
- Practical use: defining cooling programmes, estimating upper temperature limits for glassware, process control and quality assurance in glass manufacturing, and research on thermal properties of silicate and other bulk glasses.
- Typical users: materials and glass technologists, QA laboratories, research institutes, furnace/dilatometer equipment manufacturers, and standards bodies involved in glass testing and product certification.
- Relevant keywords: ISO 7884-8, dilatometric transformation temperature, glass transition temperature, dilatometry, thermal expansion, viscometric fixed points, glass testing.
Related standards
- Other parts of ISO 7884 (Parts 2–7) covering viscosity and viscometric fixed points (rotation viscometers, fibre elongation, beam bending, softening point, annealing and strain points, etc.).
- ISO 7991 - determination of coefficient of mean linear thermal expansion.
- IEC Publication 584-1 (thermocouples - reference tables).
This standard provides a reproducible, practical dilatometric procedure for characterizing glass transition behavior useful for manufacturing control, product specification, and comparative testing.
Технические детали
- Технический комитет
- ISO/TC 48 - Laboratory equipment
- SKU
- ISO 7884-8:1987
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 7884-3:1987
ДействующийGlass — Viscosity and viscometric fixed points — Part 3: Determination of viscosity by fibre elongation visco…
Overview ISO 7884-3:1987 - "Glass - Viscosity and viscometric fixed points - Part 3: Determination of viscosity by fibre elongation viscometer" specifies a laboratory method to determine the dynamic…
ISO 799-1:2019
ДействующийShips and marine technology — Pilot ladders — Part 1: Design and specification
Overview ISO 799-1:2019 - Ships and marine technology - Pilot ladders - Part 1: Design and specification defines requirements for pilot ladders used to embark and disembark maritime pilots alongside…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…