SIST EN ISO 3382-1:2009 PDF
Acoustics - Measurement of room acoustic parameters - Part 1: Performance spaces (ISO 3382-1:2009)
Acoustics - Measurement of room acoustic parameters - Part 1: Performance spaces (ISO 3382-1:2009)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 34
- Дата публикации:
- 16 июля 2009 г.
- ICS:
- 17.140.01
- Технический комитет:
- AKU - Acoustics
ISO 3382-1:2009 specifies methods for the measurement of reverberation time and other room acoustical parameters in performance spaces. It describes the measurement procedure, the apparatus needed, the coverage required, and the method of evaluating the data and presenting the test report. It is intended for the application of modern digital measuring techniques and for the evaluation of room acoustical parameters derived from impulse responses.
Abstract
Overview
EN ISO 3382-1:2009 - Acoustics: Measurement of room acoustic parameters - Part 1: Performance spaces specifies standardized methods to measure reverberation time and other key room-acoustic parameters in performance spaces (concert halls, theatres, opera houses). The standard defines measurement procedures, required apparatus, spatial coverage, data evaluation, uncertainty assessment and reporting. It is intended for use with modern digital measuring techniques and parameters derived from impulse responses.
Key topics and technical requirements
- Primary parameters: Reverberation time (T) expressed as the time for sound energy to decay by 60 dB; T can be derived from smaller dynamic ranges and labeled accordingly (e.g., T20, T30).
- Measurement methods:
- Integrated impulse-response method (reverse-time integrated squared impulse response).
- Interrupted-noise method (direct recording of decay after noise cutoff).
- Equipment and references: Omnidirectional sound sources, measurement microphones and sound level meters compliant with IEC standards (e.g., IEC 61260 octave/fractional-octave filters; IEC 61672 series). Deterministic excitation signals (maximum-length sequences, sine sweeps) are acceptable to derive impulse responses.
- Measurement conditions: Defines occupancy states (unoccupied, studio, occupied - 80–100% seating), and requires recording environmental conditions (temperature ±1 °C, relative humidity ±5 %). Notes handling of variable acoustic elements (curtains, orchestra pit) and electronic enhancement systems.
- Data processing and reporting: Procedures for evaluating decay curves, spatial averaging across measurement positions, estimating measurement uncertainty, and standardized presentation of test reports.
- Extended measures (informative annexes): Annex A (auditorium measures derived from impulse responses - early decay time, early/late energy ratios, lateral energy fractions, listener envelopment), Annex B (binaural measurements and dummy-head use), Annex C (stage/orchestra platform measures).
Applications and users
Practical uses include:
- Acoustic design and commissioning of concert halls, theatres and opera houses.
- Post‑construction acoustic verification and renovation assessment.
- Tuning of variable acoustics (canopies, curtains, acoustic panels).
- Research and binaural listening studies for venue evaluation. Primary users:
- Acoustical consultants and engineers
- Theatre and venue architects
- Audio and recording engineers
- Acoustic researchers and laboratories
- Regulatory bodies and standards organizations
Related standards
- ISO 3382-2: Reverberation time in ordinary rooms
- Future ISO 3382-3: Open-plan spaces (planned)
- IEC 61260: Octave-band and fractional-octave-band filters
- IEC 61672-1: Sound level meters - specifications
This standard is essential for anyone performing reliable, repeatable measurements of room acoustics in performance spaces and for producing comparable test reports used in design, compliance and research.
Технические детали
- SKU
- SIST EN ISO 3382-1:2009
Похожие стандарты
Стандарты, упомянутые в описании
ISO 3382-1:2009
ДействующийAcoustics — Measurement of room acoustic parameters — Part 1: Performance spaces
Overview ISO 3382-1:2009 - "Acoustics - Measurement of room acoustic parameters - Part 1: Performance spaces" specifies standardized methods for measuring reverberation time and other room acoustical…
IEC 61260-1:2014
ДействующийElectroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications
Overview IEC 61260-1:2014 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies the performance requirements for octave-band and fractional-octa…
IEC 61672-3:2013
ДействующийElectroacoustics - Sound level meters - Part 3: Periodic tests
Overview IEC 61672-3:2013 is an international standard published by the International Electrotechnical Commission (IEC) that specifies procedures for the periodic testing of sound level meters. This…
SIST EN ISO 3382-2:2008/AC:2009
ДействующийAcoustics - Measurement of room acoustic parameters - Part 2: Reverberation time in ordinary rooms (ISO 3382-…
ISO 3382-3:2022
ДействующийAcoustics — Measurement of room acoustic parameters — Part 3: Open plan offices
Overview ISO 3382-3:2022 - "Acoustics - Measurement of room acoustic parameters - Part 3: Open plan offices" specifies a standardized method to measure room-acoustic performance in unoccupied open‑pl…
IEC 61672-1:2013
ДействующийElectroacoustics - Sound level meters - Part 1: Specifications
Overview IEC 61672-1:2013 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the performance requirements for sound level meters used in elec…