SIST EN ISO 4869-1:2019 PDF
Acoustics - Hearing protectors - Part 1: Subjective method for the measurement of sound attenuation (ISO 4869-1:2018)
Acoustics - Hearing protectors - Part 1: Subjective method for the measurement of sound attenuation (ISO 4869-1:2018)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 26
- Дата публикации:
- 10 декабря 2018 г.
- ICS:
- 13.340.20
- Технический комитет:
- AKU - Acoustics
This document specifies a subjective method for measuring sound attenuation of hearing protectors at the threshold of hearing. The method is a laboratory method designed to yield reproducible values under controlled measurement conditions. The values reflect the attenuating characteristics of the hearing protector only to the extent that users wear the device in the same manner as did the test subjects. For a more representative indication of field performance the methods of ISO/TS 4869‑5 can be used. This test method yields data which are collected at low sound pressure levels (close to the threshold of hearing) but which are also representative of the attenuation values of hearing protectors at higher sound pressure levels. An exception occurs in the case of amplitude-sensitive hearing protectors for sound pressure levels above the point at which their level-dependent characteristics become effective. At those sound pressure levels the method specified in this document is inapplicable, as it will usually underestimate sound attenuation for these devices. NOTE Due to masking from physiological noise in the occluded ear tests, sound attenuations below 500 Hz can be overestimated by a few decibels.
Abstract
Overview
EN ISO 4869-1:2018 - Acoustics - Hearing protectors - Part 1: Subjective method for the measurement of sound attenuation (ISO 4869-1:2018) is a CEN-endorsed laboratory standard that defines a subjective test method for measuring the sound attenuation of hearing protectors (earplugs, earmuffs, helmets) at the threshold of hearing. The method produces reproducible attenuation values under controlled test conditions and is intended to allow consistent comparison of hearing protector performance.
Key topics and technical requirements
- Subjective measurement at threshold of hearing: Thresholds are measured with and without the hearing protector to determine sound attenuation in decibels.
- Controlled laboratory conditions: Specifications for test site acoustics (sound pressure levels, variation, reverberation time, ambient noise) to ensure reproducibility.
- Test signals and equipment: Use of defined test signals (e.g., pink noise / narrow-band signals) and electroacoustic filters compliant with referenced standards.
- Test subjects and instructions: Requirements for selecting and instructing test subjects so attenuation reflects properly fitted devices.
- Application force: Procedures for consistent donning/fit (especially for earmuffs and semi-aural earplugs) to reduce variability.
- Limitations:
- Values represent attenuation only insofar as real users wear devices as test subjects did.
- Method uses low sound pressure levels (near threshold) and may not apply to amplitude-sensitive / level-dependent protectors when their active characteristics engage - it can underestimate attenuation at higher SPLs.
- Physiological masking can cause overestimation below ~500 Hz.
- Uncertainty and reporting: Annexes cover uncertainty estimation, evaluation of repeated measurements, and minimum/maximum SPLs for test signals. A clear test report is required.
Practical applications
- Performance comparison: Manufacturers and test laboratories use EN ISO 4869-1:2018 to generate comparable attenuation data for product datasheets and R&D.
- Product development: Designers use the method to validate passive attenuation characteristics of earplugs and earmuffs.
- Regulatory & procurement: Occupational hygienists, safety officers, and procurement teams rely on standardized attenuation data when selecting hearing protection for workplaces.
- Quality control: Manufacturers and certification bodies apply the method for batch checks and conformity assessment.
Who should use this standard
- Hearing protector manufacturers, independent acoustic test laboratories, PPE certification bodies, occupational health professionals, and product developers involved in acoustic performance testing.
Related standards
- ISO/TS 4869‑5 (field performance methods)
- ISO 8253-2 (sound field audiometry)
- IEC 60263, IEC 61260-1 (frequency plotting and filters)
- ISO 389-1 (reference threshold levels)
Keywords: EN ISO 4869-1:2018, hearing protectors, sound attenuation, subjective method, acoustics, hearing protection testing.
Технические детали
- SKU
- SIST EN ISO 4869-1:2019
Похожие стандарты
Стандарты, упомянутые в описании
ISO 4869-1:2018
ДействующийAcoustics — Hearing protectors — Part 1: Subjective method for the measurement of sound attenuation
Overview ISO 4869-1:2018 - "Acoustics - Hearing protectors - Part 1: Subjective method for the measurement of sound attenuation" defines a laboratory, subjective method to measure the sound attenuati…
DD ISO/TS 4869-5:2006
ДействующийAcoustics. Hearing protectors - Method for estimation of noise reduction using fitting by inexperienced test…
1 Scope This Technical Specification specifies a method for measuring noise reduction of passive hearing protectors at the threshold of hearing . The method is designed to provide estimates of the no…
SIST EN ISO 8253-2:2010
ДействующийAcoustics - Audiometric test methods - Part 2: Sound field audiometry with pure-tone and narrow-band test sig…
Overview EN ISO 8253-2:2009 - "Acoustics - Audiometric test methods - Part 2: Sound field audiometry with pure‑tone and narrow‑band test signals" (CEN adoption of ISO 8253‑2:2009) defines procedures,…
BS EN IEC 60263:2020
ДействующийScales and sizes for plotting frequency characteristics and polar diagrams
What is BS EN IEC 60263 - Plotting frequency characteristics and polar diagrams about? BS EN IEC 60263 specifies standard aspect ratios for logarithmic or level characteristics expressed in decibels…
IEC 61260-1:2014
ДействующийElectroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications
Overview IEC 61260-1:2014 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies the performance requirements for octave-band and fractional-octa…
SIST EN ISO 389-1:2018
ДействующийAcoustics - Reference zero for the calibration of audiometric equipment - Part 1: Reference equivalent thresh…
Overview EN ISO 389-1:2018 (ISO 389-1:2017) - "Acoustics - Reference zero for the calibration of audiometric equipment - Part 1" defines the reference equivalent threshold sound pressure levels (RETS…