IEC 60645-6:2009
Electroacoustics - Audiometric equipment - Part 6: Instruments for the measurement of otoacoustic emissions
Electroacoustics - Audiometric equipment - Part 6: Instruments for the measurement of otoacoustic emissions
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 32
- Дата публикации:
- 29 апреля 2009 г.
- Издание:
- IEC IS 60645 edition 1 version 1
- ICS:
- 17.140.50
IEC 60645-6:2009 applies to instruments designed primarily for the measurement of otoacoustic emissions in the human external acoustic meatus evoked by acoustic probe pulses or tones. This standard defines the characteristics to be specified by the manufacturer, lays down performance specifications for two types of instruments and specifies the functions to be provided on these types. IEC 60645-6:2009 describes methods of test to be used for approval testing and guidance on methods for undertaking routine calibration. The purpose of IEC 60645-6:2009 is to ensure that measurements made under comparable test conditions with different instruments complying with the standard will be consistent. Instruments which provide a measurement function not specifically within the scope of the standard shall still comply with any relevant requirements. This standard is not intended to restrict development or incorporation of new features, nor to discourage innovative approaches.
Abstract
Overview
IEC 60645-6:2009 is an international standard published by the International Electrotechnical Commission (IEC) that focuses on electroacoustics specifically for audiometric equipment. This part addresses instruments designed for the measurement of otoacoustic emissions (OAE) in the human external acoustic meatus. Otoacoustic emissions are sounds generated by the inner ear, which can be evoked by acoustic probe pulses or tones and measured using specialized equipment. The standard sets out the minimum performance specifications, essential functions, and testing methods to ensure accuracy, consistency, and reliability of OAE measuring instruments.
The primary goal of IEC 60645-6:2009 is to promote comparable measurement results across different instruments under similar test conditions - an important factor for clinical diagnostics, hearing research, and auditory health assessments.
Key Topics
-
Scope of Application:
IEC 60645-6 applies to instruments designed mainly for measuring otoacoustic emissions using acoustic stimuli such as probe pulses or tones. It includes definitions, performance criteria, testing methods, and calibration guidance for two types of OAE measurement devices. -
Performance and Functional Specifications:
The standard defines characteristics that manufacturers must specify for their instruments, including stimulus types, stimulus frequency and levels, harmonic distortion limits, and measurement accuracy. It covers:- Acoustic stimulus systems and their performance requirements
- Test quality assurance systems to validate data integrity
- Measurement ranges, noise reduction techniques, and frequency response
- Presentation of primary and secondary measurement results
-
Testing and Calibration Methods:
IEC 60645-6 guides both approval testing and routine calibration methods to verify conformity with the specifications, supporting standardized quality control and maintenance. -
Safety and Electromagnetic Compatibility:
Instrument safety, immunity to power variations and radiofrequency fields, warm-up time, and power supply conditions (mains and battery operation) are addressed to ensure reliable operation in clinical settings. -
Documentation and Marking:
The standard requires clear marking of equipment and comprehensive user manuals, ensuring ease of use and traceability of measurement conditions and parameters.
Applications
-
Hearing Diagnostics:
OAE measurements are widely used in audiology clinics for screening newborns, diagnosing cochlear function, and evaluating hearing impairments. IEC 60645-6 compliant instruments provide trusted data that support accurate hearing assessments. -
Research and Clinical Studies:
Researchers rely on consistent measurement methods to study inner ear function and otoacoustic emissions in both healthy and impaired populations, advancing knowledge of auditory physiology. -
Hearing Device Evaluation:
The standard supports testing hearing aids and other audiometric devices where otoacoustic emissions are part of device diagnostics or monitoring protocols. -
Product Development and Compliance:
Manufacturers of audiometric equipment use IEC 60645-6 to guide product design, performance verification, and regulatory compliance, ensuring their instruments meet international quality benchmarks.
Related Standards
- IEC 60645-1: Pure-tone audiometers – Specifies requirements for audiometric devices generating pure-tone signals for hearing tests.
- IEC 60645-3: Test signals of short duration – Details specifications for test signals used in audiometric equipment.
- IEC 60601 series: Medical electrical equipment – Covers basic safety, essential performance, and electromagnetic compatibility requirements crucial for audiometric instruments.
- IEC 60318-4 and IEC 60318-5: Simulators of human head and ear – Define test couplers and occluded-ear simulators used to standardize measurements related to earphones and hearing devices.
- ISO/IEC Guide 98-3: Guide to the expression of uncertainty in measurement – Provides foundational principles for quantifying measurement uncertainty necessary in calibration and testing of audiometric equipment.
By adhering to IEC 60645-6:2009, manufacturers and users of otoacoustic emission measuring instruments can ensure high-accuracy, reliable diagnostic outcomes, and international conformity essential for advancing hearing healthcare technologies and practices. This globally recognized standard fosters innovation while maintaining robust quality assurance in electroacoustic audiometric testing.
Технические детали
- Технический комитет
- TC 29 - Electroacoustics
- SKU
- IEC 60645-6:2009
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60645-1:2017
ДействующийElectroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry
Overview IEC 60645-1:2017 - "Electroacoustics - Audiometric equipment - Part 1: Equipment for pure‑tone and speech audiometry" is an international standard that specifies general technical and perfor…
IEC 60645-3:2020
Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration
Overview IEC 60645-3:2020, titled Electroacoustics - Audiometric Equipment - Part 3: Test Signals of Short Duration, is an international standard developed by the International Electrotechnical Commi…
IEC 60601-2-91:2026
ДействующийMedical electrical equipment - Part 2-91: Particular requirements for basic safety and essential performance…
Overview IEC 60601-2-91:2026 specifies the particular requirements for the basic safety and essential performance of non-thermal plasma wound treatment equipment and associated accessories. Developed…
IEC 60318-4:2010
ДействующийElectroacoustics - Simulators of human head and ear - Part 4: Occluded-ear simulator for the measurement of e…
Overview IEC 60318-4:2010 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the design and application of an occluded-ear simulator. This el…
IEC 60318-5:2006
ДействующийElectroacoustics - Simulators of human head and ear - Part 5: 2 cm3 coupler for the measurement of hearing ai…
Overview IEC 60318-5:2006 is an international standard issued by the International Electrotechnical Commission (IEC) that focuses on electroacoustics, specifically simulators of the human head and ea…