IEC 60966-2-8:2022
Radio frequency and coaxial cable assemblies - Part 2-8: Detail specification for cable assemblies for radio and TV receivers - Frequency range up to 3000 MHz, Screening class A++, IEC 61169-47 connectors
Radio frequency and coaxial cable assemblies - Part 2-8: Detail specification for cable assemblies for radio and TV receivers - Frequency range up to 3000 MHz, Screening class A++, IEC 61169-47 connectors
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 21
- Дата публикации:
- 17 июня 2022 г.
- Издание:
- IEC IS 60966 edition 1 version 1
- ICS:
- 33.120.01
IEC 60966-2-8:2022 is a detail specification that applies to cable assemblies with F-Quick connectors (see IEC 61169-47) and requires quad-shield screening class A++ (see IEC 61196-6-5). This detail specification applies to the cable assemblies for radio and TV receivers. This detail specification gives subfamily requirements and severities which shall be applied.
Abstract
Overview
IEC 60966-2-8:2022 is an international standard from the International Electrotechnical Commission (IEC) that specifies the requirements for radio frequency (RF) and coaxial cable assemblies used with radio and TV receivers. This detail specification addresses cable assemblies with F-Quick connectors in accordance with IEC 61169-47 and demands quad-shield screening class A++ performance as specified in IEC 61196-6-5, supporting reliable transmission up to 3000 MHz. The standard defines the subfamily requirements, test severities, identification, and marking for these cable assemblies.
Key Topics
-
Scope and Purpose
- Applies to cable assemblies with F-Quick connectors, designed for radio and TV receiver applications.
- Covers cable types with quad-shield screening class A++ to ensure high electromagnetic compatibility (EMC) and minimal signal loss.
- Specifies requirements for assemblies’ components, performance, marking, and type variants.
-
Assemblies and Connectors
- Utilizes F-Quick connectors as per IEC 61169-47, suitable for use in 75 Ω coaxial cable networks.
- Supports both straight and right-angled, male or female connector variants for flexible installation.
-
Screening and Performance
- Requires quad-shield cables (screening class A++), providing high shielding efficiency for robust EMC.
- Addresses key cable characteristics, including nominal impedance (75 Ω) and frequency range up to 3000 MHz.
-
Marking and Identification
- Mandates clear marking on cable sheaths, including type name, screening class, IEC standard number, and manufacturer’s identification.
- Example of marking:
75-4-FM-FRF-1.5m [IEC 60966-2-8](/search?q=IEC%2060966-2-8)
-
Testing and Quality Assurance
- References subfamily requirements and test severities for both electrical and mechanical performance.
- Asserts testing for return loss, insertion loss, transfer impedance, screening attenuation, voltage proof, and mechanical endurance.
Applications
Cable assemblies conforming to IEC 60966-2-8:2022 are ideal for:
-
Radio and Television Receivers
- Ensuring reliable RF signal transmission in consumer and professional broadcast applications.
- Suitable for digital and analog TV, radio tuners, set-top boxes, and multimedia receivers.
-
Home and Commercial Installations
- Providing high-performance connectivity in residential cable networks, satellite TV setups, and hotel entertainment systems.
- Supporting installations requiring low signal loss and strong EMC shielding, especially in environments with high electromagnetic interference.
-
CATV and MATV Systems
- Used in community antenna television (CATV) and master antenna television (MATV) networks where robust signal integrity is critical.
Related Standards
For effective implementation and compliance, consider these associated standards:
- IEC 60966-1: Generic requirements and test methods for RF and coaxial cable assemblies.
- IEC 60966-2-1: Sectional specification for flexible coaxial cable assemblies.
- IEC 60966-2-2: Blank detail specification for flexible coaxial cable assemblies.
- IEC 61169-47: Sectional specification for RF coaxial connectors (F-Quick type).
- IEC 61196-6-5: Detailed specification for quad-shield CATV drop cables with screening class A++.
- IEC 62153-4-7: Test methods for electromagnetic compatibility (EMC) of connectors and assemblies.
Practical Value
By adhering to IEC 60966-2-8:2022, manufacturers and installers ensure:
- Standardized high-quality RF performance in radio and TV signal distribution systems.
- Interoperability across products from different vendors.
- Reduced electromagnetic interference and signal loss in cable assemblies.
- Clear, traceable product marking for easy identification and quality control.
- Assurance that cable assemblies meet rigorous mechanical and electrical testing for long-term reliability.
IEC 60966-2-8:2022 is essential for anyone involved in designing, producing, testing, or installing RF coaxial cable assemblies for radio and television receivers, ensuring consistent quality and robust performance in a wide range of broadcast and telecommunications environments.
Технические детали
- Технический комитет
- TC 46 - Cables, wires, waveguides, RF connectors, RF and microwave passive components and accessories
- SKU
- IEC 60966-2-8:2022
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60966-2-7:2015
ДействующийRadio frequency and coaxial cable asemblies - Part 2-7: Detail specification for cable assemblies for radio a…
Overview IEC 60966-2-7:2015 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies requirements for radio frequency (RF) and coaxial cable assemb…
IEC 61196-6-5:2020
ДействующийCoaxial communication cables - Part 6-5: Detail specification for Type A quad-shield CATV drop cables with sc…
Overview IEC 61196-6-5:2020 is an international detail specification for Type A quad-shield CATV drop cables with screening class A++. It applies to coaxial communication cables described in IEC 6119…
IEC 60966-2-8:2025
ДействующийRadio frequency and coaxial cable assemblies - Part 2-8: Detail specification for cable assemblies for radio…
Overview IEC 60966-2-8:2025 is an international standard published by the International Electrotechnical Commission (IEC). It provides a detailed specification for radio frequency (RF) and coaxial ca…
IEC 60966-1:2019
ДействующийRadio frequency and coaxial cable assemblies - Part 1: Generic specification - General requirements and test…
Overview IEC 60966-1:2019 - "Radio frequency and coaxial cable assemblies - Part 1: Generic specification - General requirements and test methods" - is the third edition of the generic IEC specificat…
IEC 60966-2-1:2008
ДействующийRadio frequency and coaxial cable assemblies - Part 2-1: Sectional specification for flexible coaxial cable a…
Overview IEC 60966-2-1:2008 is a key international standard developed by the International Electrotechnical Commission (IEC) that provides a sectional specification for flexible coaxial cable assembl…
IEC 60966-2-2:2024
ДействующийRadio frequency and coaxial cable assemblies - Part 2-2: Blank detail specification for flexible coaxial cabl…
Overview IEC 60966-2-2:2024 is an international standard published by the International Electrotechnical Commission (IEC). It specifies a blank detail specification for flexible coaxial cable assembl…
IEC 62153-4-7:2021
ДействующийMetallic cables and other passive components test methods - Part 4-7: Electromagnetic compatibility (EMC) - T…
Overview IEC 62153-4-7:2021 is an international standard developed by the International Electrotechnical Commission (IEC) for testing metallic cables and other passive components. It specifies the tr…