IEC 62893-3:2017
Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 3: Cables for AC charging according to modes 1, 2 and 3 of IEC 61851-1 of rated voltages up to and including 450/750 V
Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 3: Cables for AC charging according to modes 1, 2 and 3 of IEC 61851-1 of rated voltages up to and including 450/750 V
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 15
- Дата публикации:
- 22 ноября 2017 г.
- Издание:
- IEC IS 62893 edition 1 version 1
- ICS:
- 29.060.20
IEC 62893-3:2017(E) applies to cables for AC charging according to modes 1, 2 and 3 of IEC 61851-1. The cables are of rated voltages U0/U up to and including 450/750 V. Ordinary duty cables with rated voltage 300/500 V are only permitted for charging mode 1 of IEC 61851-1. Maximum conductor operating temperature for the cables in this document is 90 ºC.
Abstract
Overview
IEC 62893-3:2017 is an international standard that specifies requirements for charging cables used for AC charging of electric vehicles (EVs) according to modes 1, 2 and 3 of IEC 61851-1. It covers cables of the IEC 0,6/1 kV family with rated voltages up to and including 450/750 V and sets a maximum conductor operating temperature of 90 °C. Ordinary-duty flexible cables rated 300/500 V are permitted only for charging mode 1.
Key topics and technical requirements
- Scope and cable types: Defines ordinary duty (types 62893 IEC 121, 122) and heavy duty (types 62893 IEC 123, 124, 125) flexible cables for EV AC charging.
- Rated voltages: Cables rated 300/500 V (ordinary duty) and 450/750 V (heavy duty).
- Conductor sizes and construction: Power core sizes include 1.5 mm2 and 2.5 mm2 for ordinary duty; heavy duty covers 1.5 mm2 up to 35 mm2 and 3–5 core constructions; cores are class 5 flexible conductors and are twisted/assembled with non-adhering sheaths.
- Insulation and sheath materials: Insulation compounds (EVI-1, EVI-2) and halogen-free sheath compounds (EVM-1, EVM-2, EVM-3) are specified by cable type; sheath must not adhere to cores.
- Marking and dimensioning: Marking requirements refer to IEC 62893-1; dimensional and insulation thickness data are provided in Annex B tables.
- Testing and verification: Test methods and performance requirements reference IEC 62893-2, IEC 60245-2, IEC 60332-1-2, IEC 62821-1 and relevant IEC 60811 parts. Annex A lists tests for completed cables (compatibility, cold impact, crush resistance, fire performance, etc.).
- Use guidance: Clause 5 refers to IEC 62440 for safe use and includes tables for intended environmental and duty conditions.
Applications and who uses this standard
- Cable manufacturers designing and producing EV charging cables for AC charging (modes 1–3).
- EVSE (Electric Vehicle Supply Equipment) OEMs specifying compatible charging leads and assemblies.
- Test laboratories and conformity assessors performing required tests per Annex A and referenced documents.
- Specifiers, procurement teams and safety engineers ensuring product selection meets rated voltage, temperature and mechanical requirements.
- Regulators and certification bodies referencing IEC 62893-3:2017 for compliance with EV charging safety and performance.
Related standards
- IEC 61851-1 (EV conductive charging system - general requirements)
- IEC 62893-1 (General requirements for EV charging cables)
- IEC 62893-2 (Test methods)
- IEC 62440 (Guide to safe use of cables)
- IEC 60245-2, IEC 60332-1-2, IEC 60811 (referenced test and material standards)
Keywords: IEC 62893-3:2017, charging cables, electric vehicles, AC charging, 450/750 V, modes 1 2 3, IEC 61851-1, EVM, EVI, cable testing.
Технические детали
- Технический комитет
- TC 20 - Electric cables
- SKU
- IEC 62893-3:2017
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61851-1:2017
ДействующийElectric vehicle conductive charging system - Part 1: General requirements
Overview IEC 61851-1:2017 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies the general requirements for electric vehicle (EV) conductive ch…
IEC 62893-1:2017
ДействующийCharging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 1: General requi…
Overview - IEC 62893-1:2017 (EV charging cable standard) IEC 62893-1:2017 defines the general requirements for electric vehicle (EV) charging cables with extruded insulation and sheath rated up to an…
IEC 62893-2:2017
ДействующийCharging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 2: Test methods
Overview IEC 62893-2:2017 - Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 2: Test methods - specifies test methods specific to EV charging cables with e…
IEC 60332-1-2:2025
ДействующийTests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagat…
Overview IEC 60332-1-2:2025 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies procedures for testing the resistance to vertical flame propag…
IEC 62821-1:2015
ДействующийElectric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up t…
Overview IEC 62821-1:2015 is an international standard published by the International Electrotechnical Commission (IEC) that specifies general requirements for halogen-free, low smoke, thermoplastic…
IEC 60811-407:2012
ДействующийElectric and optical fibre cables - Test methods for non-metallic materials - Part 407: Miscellaneous tests -…
Overview IEC 60811-407:2012 is an internationally recognized standard established by the International Electrotechnical Commission (IEC). It defines the test methods for non-metallic materials used i…
IEC 62440:2008
ДействующийElectric cables with a rated voltage not exceeding 450/750 V - Guide to use
Overview IEC 62440:2008 is an international standard developed by the International Electrotechnical Commission (IEC) that provides comprehensive guidance on the safe use of electric cables with rate…