ISO 11040-3:2025
Prefilled syringes — Part 3: Seals for dental local anaesthetic cartridges
Prefilled syringes — Part 3: Seals for dental local anaesthetic cartridges
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 7
- Дата публикации:
- 7 ноября 2025 г.
- Издание:
- ISO IS 11040 edition 3 version 1
- ICS:
- 11.040.25
This document specifies the shape, dimensions, material, performance requirements and labelling of seals for dental local anaesthetic cartridges intended for single use only. NOTE The potency, purity, stability and safety of a medicinal product during its manufacture and storage can be significantly affected by the nature and performance of the primary packaging.
Abstract
Overview
ISO 11040-3:2025 - Prefilled syringes: Seals for dental local anaesthetic cartridges specifies the shape, dimensions, materials, performance requirements and labelling of single‑use seals (aluminium cap + elastomeric liner) used on dental local anaesthetic cartridges. The standard emphasizes the role of primary packaging in maintaining the potency, purity, stability and safety of medicinal products and aligns component production with good manufacturing practice (cGMP) principles.
Key topics and technical requirements
- Classification
- Type A: mono‑layer liner
- Type B: double‑layer liner (both layers continuous; layer thickness ratio agreed with customer)
- Shape & dimensions
- Standard nominal size example: 7.5 mm opening diameter.
- Typical cap/liner ranges (as specified): Type A cap height ~4.85–4.90 mm, liner thickness 1.3–1.5 mm; Type B cap height up to 5.3 mm, liner thickness 1.45–1.95 mm. Aluminium thickness to be agreed (example range 0.15–0.25 mm).
- Materials
- Aluminium cap: anodized, lacquered or suitably coated (see ISO 8872).
- Liner: elastomer or TPE formulation approved by the customer; manufacturer must ensure batch conformity.
- Liner must withstand two autoclave cycles at (121 ± 2) °C for 30 min (or be validated for other sterilization methods).
- Physical performance
- Hardness: ±5 IRHD from the agreed nominal value (tested per ISO 48‑4).
- Fragmentation: test per ISO 8871‑5:2025 using a 0.4 mm outer diameter needle (butt‑end needle geometry per ISO 7885).
- Freedom from leakage: assessed using the Annex A leakage test (water‑filled cartridges, 30 ± 1 N applied for 1 minute on a set of 10 cartridges).
- Ageing: seals must maintain performance over agreed shelf‑life; storage guidance per ISO 2230.
- Chemical & biological
- Chemical extractables per ISO 8871‑1; biological requirements and test methods per ISO 8871‑4. Biological hazard assessment may follow ISO 10993‑1 when relevant.
- Labelling & designation
- Designation format e.g. Seal ISO 11040-3 - A for type A seals.
Applications and users
This standard is intended for:
- Manufacturers of elastomeric seals, aluminium caps and prefilled dental cartridges
- Pharmaceutical pack producers and contract packagers producing dental local anaesthetic cartridges
- Quality, regulatory and validation engineers who perform incoming inspection, stability and compatibility testing
- Procurement and R&D teams specifying primary packaging for dental injectable products Use cases include component design, supplier qualification, incoming acceptance testing, and regulatory documentation to demonstrate compliance for dental cartridge primary packaging.
Related standards
- ISO 11040 series (Parts 1 & 2) - glass cylinders and plunger stoppers for dental cartridges
- ISO 8871‑1, ISO 8871‑4, ISO 8871‑5:2025 - elastomeric parts requirements and tests
- ISO 48‑4 (hardness), ISO 3302‑1 (dimensional tolerances), ISO 7885 (injection needles)
- ISO 8872 (aluminium caps), ISO 15378 (cGMP for primary packaging)
Keywords: ISO 11040-3, prefilled syringes, seals for dental local anaesthetic cartridges, dental cartridges, liner, aluminium cap, leakage test, elastomeric parts, sterilization, cGMP.
Технические детали
- Технический комитет
- ISO/TC 76 - Transfusion, infusion and injection, and blood processing equipment for medical and pharmaceutical use
- SKU
- ISO 11040-3:2025
Похожие стандарты
Стандарты, упомянутые в описании
ISO 8871-5:2025
ДействующийElastomeric parts for parenterals and for devices for pharmaceutical use — Part 5: Functional requirements an…
Overview ISO 8871-5:2025 - Elastomeric parts for parenterals and for devices for pharmaceutical use - Part 5: Functional requirements and testing defines functional requirements and test methods for…
ISO 887:2000
ДействующийPlain washers for metric bolts, screws and nuts for general purposes — General plan
Overview ISO 887:2000 - Plain washers for metric bolts, screws and nuts for general purposes - General plan defines the nominal dimensional framework and preferred combinations for plain (flat) washe…
ISO 484-1:1981
ОтменёнShipbuilding — Ship screw propellers — Manufacturing tolerances — Part 1: Propellers of diameter greater than…
ISO 7885:2010
ДействующийDentistry — Sterile injection needles for single use
Overview ISO 7885:2010 - "Dentistry - Sterile injection needles for single use" specifies dimensional and performance requirements for sterile dental injection needles designed for use with dental ca…
ISO 22303:2008
ОтменёнTobacco — Determination of tobacco specific nitrosamines — Method using buffer extraction
Overview ISO 22303:2008 specifies a laboratory method for the determination of tobacco specific nitrosamines (TSNAs) - N‑nitrosonornicotine (NNN), N‑nitrosoanatabine (NAT), N‑nitrosoanabasine (NAB) a…
ISO 8871-1:2003
ДействующийElastomeric parts for parenterals and for devices for pharmaceutical use — Part 1: Extractables in aqueous au…
Overview ISO 8871-1:2003 - “Elastomeric parts for parenterals and for devices for pharmaceutical use - Part 1: Extractables in aqueous autoclavates” defines chemical evaluation procedures for elastom…
ISO 8871-4:2006
ДействующийElastomeric parts for parenterals and for devices for pharmaceutical use — Part 4: Biological requirements an…
Overview ISO 8871-4:2006 - "Elastomeric parts for parenterals and for devices for pharmaceutical use - Part 4: Biological requirements and test methods" defines the biological safety requirements and…