ISO 12567-1:2010 specifies a method to measure the thermal transmittance of a door or window system. It is applicable to all effects of frames, sashes, shutters, blinds, screens, panels, door leaves and fittings. It is not applicable to edge effects occurring outside the perimeter of the specimen, energy transfer due to solar radiation on the specimen, effects of air leakage through the specimen, and roof windows and projecting products, where the external face projects beyond the cold side roof surface.
Abstract
Overview
ISO 12567-1:2010 - "Thermal performance of windows and doors - Determination of thermal transmittance by the hot‑box method - Part 1: Complete windows and doors" specifies a standardized laboratory method to measure the thermal transmittance (U‑value) of complete window and door systems using a calibrated or guarded hot‑box. The procedure accounts for frames, sashes, shutters, blinds, screens, panels, door leaves and fittings, and provides corrections for edge/boundary effects to produce reproducible U‑value results for product comparison and performance evaluation.
Key topics and technical requirements
- Measurement principle: Two‑stage hot‑box method based on ISO 8990 - calibration with known panels, then measurement of the specimen using the same fan and boundary conditions.
- Scope and exclusions: Applicable to complete windows and doors; not applicable to edge effects outside the specimen perimeter, solar radiation on the specimen, air leakage through the specimen, or projecting/roof windows (see ISO 12567‑2 for projecting products).
- Surround and calibration panels: Use of a surround panel to position specimens and calibration panels with known thermal properties to determine surface heat transfer coefficients (radiative and convective).
- Edge correction: Linear thermal transmittance (Ψ) correction for boundary/edge heat flow as given in Annex B or calculated per ISO 10211.
- Test specimen preparation: Specimen mounting, sealing (gaps ≤ 5 mm guidance) and measures to prevent air permeability affecting results (pressure equalization or internal sealing).
- Data and reporting: Instructions for test procedure, expression of standardized results, and required test report content.
- Uncertainty and calibration: Annexes include environmental temperature calculations (A), calibration examples (D), analytical calibration (E), and uncertainty analysis for hot boxes (F).
- Normative references: ISO 8990, ISO 7345, ISO 8301, ISO 8302, ISO 9288, ISO 10211, EN 12898, IEC 60584‑1.
Applications and who uses it
ISO 12567‑1 is used by:
- Test laboratories performing U‑value measurements on windows and doors.
- Manufacturers validating product thermal performance for datasheets and quality control.
- Product certifiers and compliance bodies assessing conformity with building regulations and energy labeling.
- Architects, façade engineers and energy assessors requiring reliable laboratory U‑values for building energy models.
- Research institutions investigating thermal bridge effects, glazing systems and façade performance.
Practical uses include product comparison, compliance documentation, input for building energy simulation, and R&D of low‑U glazing and frame systems.
Related standards
- ISO 12567‑2 (roof and projecting windows)
- ISO 8990 (calibrated and guarded hot box)
- ISO 10211 (thermal bridges)
- ISO 7345, ISO 8301, ISO 8302, ISO 9288 (thermal measurement and definitions)
Keywords: ISO 12567‑1, thermal transmittance, U‑value, hot‑box method, windows and doors, thermal performance, calibration, surround panel, linear thermal transmittance, measurement uncertainty.
Технические детали
- Технический комитет
- ISO/TC 163/SC 1 - Test and measurement methods
- SKU
- ISO 12567-1:2010
Похожие стандарты
Стандарты, упомянутые в описании
ISO 8990:1994
ДействующийThermal insulation — Determination of steady-state thermal transmission properties — Calibrated and guarded h…
Overview ISO 8990:1994 - Thermal insulation - Determination of steady‑state thermal transmission properties - Calibrated and guarded hot box - defines the principles, measurement techniques and minim…
BS EN ISO 12567-2:2005
ДействующийThermal performance of windows and doors. Determination of thermal transmittance by hot box method. Roof wind…
BS EN ISO 10211:2017-TC
ДействующийTracked Changes. Thermal bridges in building construction. Heat flows and surface temperatures. Detailed calc…
ISO 7345:2018
ДействующийThermal performance of buildings and building components — Physical quantities and definitions
Overview ISO 7345:2018 - "Thermal performance of buildings and building components - Physical quantities and definitions" is an ISO standard that defines the physical quantities, symbols and units us…
ISO 830:1999
ОтменёнFreight containers — Vocabulary
Overview ISO 830:1999 - "Freight containers - Vocabulary" is an ISO International Standard that defines the terminology used for freight containers. It provides a common vocabulary for the container…
ISO 830:2024
ДействующийFreight containers — Vocabulary
Overview - ISO 830:2024 (Freight containers - Vocabulary) ISO 830:2024 is the third edition (published September 2024) of the ISO vocabulary standard for freight containers. It defines universally ac…
ISO 9288:1989
ОтменёнThermal insulation — Heat transfer by radiation — Physical quantities and definitions
IEC 60584-1:2013
ДействующийThermocouples - Part 1: EMF specifications and tolerances
Overview IEC 60584-1:2013 is an authoritative international standard published by the International Electrotechnical Commission (IEC), focusing on thermocouples. This standard-Part 1 of the IEC 60584…